-- ***************************************************************************************** -- PMD-4206 MIB File -- 2019/08/08 -- Version: v1.0.0 -- ***************************************************************************************** ICPDAS-PMD4206-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, Opaque, Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE FROM SNMPv2-SMI; -- 1.3.6.1.4.1.34321.31.4206 pmd4206 MODULE-IDENTITY LAST-UPDATED "201908081417Z" ORGANIZATION "ICP DAS CO., LTD." CONTACT-INFO "No. 111, Guangfu N. Rd., Hukou Township, Hsinchu County 30351, Taiwan, R.O.C. Tel: +886-3-5973366 FAX: +886-3-5973733" DESCRIPTION "The MIB For PMD-4206." REVISION "201908081417Z" DESCRIPTION " " ::= { pmc 4206 } -- 1.3.6.1.4.1.34321 icpdas OBJECT IDENTIFIER ::= { enterprises 34321 } -- 1.3.6.1.4.1.34321.31 pmc OBJECT IDENTIFIER ::= { icpdas 31 } -- 1.3.6.1.4.1.34321.31.4206.1 systemInfo OBJECT IDENTIFIER ::= { pmd4206 1 } -- 1.3.6.1.4.1.34321.31.4206.1.1 serialNumber OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The hardware serial number of the device." ::= { systemInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.1.2 firmwareVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The firmware version of the device." ::= { systemInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.1.3 nickname OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The nickname of the device." ::= { systemInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.1.4 systemCurrentTime OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The system current time of the device." ::= { systemInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.1.5 networkInfo OBJECT IDENTIFIER ::= { systemInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.1.5.1 webserverPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The web server port of the device." ::= { networkInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.1.5.2 modbusTcpPort OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus TCP slave port of the device." ::= { networkInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.1.5.3 modbusTcpNetID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus TCP NetID of the device." ::= { networkInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.1.6 microSDFreeSpace OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The free space of the microSD card." ::= { systemInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.1.7 moduleAmount OBJECT IDENTIFIER ::= { systemInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.1.7.1 powerMeterAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the connected power meters." ::= { moduleAmount 1 } -- 1.3.6.1.4.1.34321.31.4206.1.7.2 ioModuleAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the connected I/O modules." ::= { moduleAmount 2 } -- 1.3.6.1.4.1.34321.31.4206.1.8 powerManagerInfo OBJECT IDENTIFIER ::= { systemInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.1.8.1 demandInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The demand interval setting." ::= { powerManagerInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.1.8.2 contractCapacity OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The contract capacity setting." ::= { powerManagerInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.1.8.3 carbonFootprintFactor OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The carbon footprint factor value." ::= { powerManagerInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.1.9 smsStatus OBJECT IDENTIFIER ::= { systemInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.1.9.1 modemStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status of SMS modem (0=Initial success)." ::= { smsStatus 1 } -- 1.3.6.1.4.1.34321.31.4206.1.9.2 registerStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The SMS register status: 0=Not registered 1=Registered, home network 2=Not registered, and searching 3=Registration denied 4=Unknown 5=Registered, roaming " ::= { smsStatus 2 } -- 1.3.6.1.4.1.34321.31.4206.1.9.3 signal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The intensity of the signal." ::= { smsStatus 3 } -- 1.3.6.1.4.1.34321.31.4206.2 powerMeterInfo OBJECT IDENTIFIER ::= { pmd4206 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1 com1pm OBJECT IDENTIFIER ::= { powerMeterInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1 com1pm1 OBJECT IDENTIFIER ::= { com1pm 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1 com1pm1BasicInfo OBJECT IDENTIFIER ::= { com1pm1 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.1 com1pm1Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm1BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.2 com1pm1Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm1BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.3 com1pm1ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm1BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.4 com1pm1Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm1BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.5 com1pm1PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.5.1 com1pm1PtEntry OBJECT-TYPE SYNTAX Com1pm1PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1PtIndex } ::= { com1pm1PtTable 1 } Com1pm1PtEntry ::= SEQUENCE { com1pm1PtIndex Integer32, com1pm1PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.5.1.1 com1pm1PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm1PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.5.1.2 com1pm1PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm1PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.6 com1pm1CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.6.1 com1pm1CtEntry OBJECT-TYPE SYNTAX Com1pm1CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1CtIndex } ::= { com1pm1CtTable 1 } Com1pm1CtEntry ::= SEQUENCE { com1pm1CtIndex Integer32, com1pm1CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.6.1.1 com1pm1CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm1CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.6.1.2 com1pm1CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm1CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.9 com1pm1DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm1BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.10 com1pm1DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm1BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.11 com1pm1AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm1BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.12 com1pm1AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm1BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.13 com1pm1PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm1BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.14 com1pm1RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm1BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.15 com1pm1ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm1BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.1.16 com1pm1StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm1BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2 com1pm1ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1 com1pm1ChEntry OBJECT-TYPE SYNTAX Com1pm1ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1ChSubmeterIndex } ::= { com1pm1ChTable 1 } Com1pm1ChEntry ::= SEQUENCE { com1pm1ChSubmeterIndex Integer32, com1pm1ChName OCTET STRING, com1pm1ChVoltage Opaque, com1pm1ChCurrent Opaque, com1pm1ChKW Opaque, com1pm1ChKvar Opaque, com1pm1ChKVA Opaque, com1pm1ChPF Opaque, com1pm1ChKWh Opaque, com1pm1ChKvarh Opaque, com1pm1ChKVAh Opaque, com1pm1ChActualDemand Opaque, com1pm1ChForecastDemand Opaque, com1pm1ChMaxDemandH Opaque, com1pm1ChMaxDemandD Opaque, com1pm1ChMaxDemandM Opaque, com1pm1ChElectricityD Opaque, com1pm1ChElectricityM Opaque, com1pm1ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.0 com1pm1ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm1ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.1 com1pm1ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm1ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.2 com1pm1ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm1ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.3 com1pm1ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm1ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.4 com1pm1ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm1ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.5 com1pm1ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm1ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.6 com1pm1ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm1ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.7 com1pm1ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm1ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.8 com1pm1ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm1ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.9 com1pm1ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm1ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.10 com1pm1ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm1ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.11 com1pm1ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm1ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.12 com1pm1ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm1ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.13 com1pm1ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm1ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.14 com1pm1ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm1ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.15 com1pm1ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm1ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.16 com1pm1ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm1ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.17 com1pm1ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm1ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.2.1.18 com1pm1ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm1ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3 com1pm1IOinfo OBJECT IDENTIFIER ::= { com1pm1 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.1 com1pm1DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.1.1 com1pm1DIEntry OBJECT-TYPE SYNTAX Com1pm1DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1DIIndex } ::= { com1pm1DITable 1 } Com1pm1DIEntry ::= SEQUENCE { com1pm1DIIndex Integer32, com1pm1DIName OCTET STRING, com1pm1DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.1.1.1 com1pm1DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm1DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.1.1.2 com1pm1DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm1DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.1.1.3 com1pm1DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm1DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.2 com1pm1DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.2.1 com1pm1DOEntry OBJECT-TYPE SYNTAX Com1pm1DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1DOIndex } ::= { com1pm1DOTable 1 } Com1pm1DOEntry ::= SEQUENCE { com1pm1DOIndex Integer32, com1pm1DOName OCTET STRING, com1pm1DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.2.1.1 com1pm1DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm1DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.2.1.2 com1pm1DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm1DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.2.1.3 com1pm1DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm1DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.3 com1pm1AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.3.1 com1pm1AIEntry OBJECT-TYPE SYNTAX Com1pm1AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1AIIndex } ::= { com1pm1AITable 1 } Com1pm1AIEntry ::= SEQUENCE { com1pm1AIIndex Integer32, com1pm1AIName OCTET STRING, com1pm1AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.3.1.1 com1pm1AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm1AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.3.1.2 com1pm1AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm1AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.3.1.3 com1pm1AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm1AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.4 com1pm1AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.4.1 com1pm1AOEntry OBJECT-TYPE SYNTAX Com1pm1AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1AOIndex } ::= { com1pm1AOTable 1 } Com1pm1AOEntry ::= SEQUENCE { com1pm1AOIndex Integer32, com1pm1AOName OCTET STRING, com1pm1AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.4.1.1 com1pm1AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm1AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.4.1.2 com1pm1AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm1AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.3.4.1.3 com1pm1AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm1AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.4 com1pm1HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm1HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm1 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.4.1 com1pm1HarmonicEntry OBJECT-TYPE SYNTAX Com1pm1HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm1HarmonicSubmeterIndex } ::= { com1pm1HarmonicTable 1 } Com1pm1HarmonicEntry ::= SEQUENCE { com1pm1HarmonicSubmeterIndex Integer32, com1pm1HarmonicSelector Integer32, com1pm1HarmonicVTHD Opaque, com1pm1HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.4.1.1 com1pm1HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm1HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.4.1.2 com1pm1HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm1HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.4.1.3 com1pm1HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm1HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.1.4.1.4 com1pm1HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm1HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2 com1pm2 OBJECT IDENTIFIER ::= { com1pm 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1 com1pm2BasicInfo OBJECT IDENTIFIER ::= { com1pm2 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.1 com1pm2Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm2BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.2 com1pm2Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm2BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.3 com1pm2ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm2BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.4 com1pm2Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm2BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.5 com1pm2PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.5.1 com1pm2PtEntry OBJECT-TYPE SYNTAX Com1pm2PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2PtIndex } ::= { com1pm2PtTable 1 } Com1pm2PtEntry ::= SEQUENCE { com1pm2PtIndex Integer32, com1pm2PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.5.1.1 com1pm2PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm2PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.5.1.2 com1pm2PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm2PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.6 com1pm2CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.6.1 com1pm2CtEntry OBJECT-TYPE SYNTAX Com1pm2CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2CtIndex } ::= { com1pm2CtTable 1 } Com1pm2CtEntry ::= SEQUENCE { com1pm2CtIndex Integer32, com1pm2CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.6.1.1 com1pm2CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm2CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.6.1.2 com1pm2CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm2CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.9 com1pm2DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm2BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.10 com1pm2DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm2BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.11 com1pm2AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm2BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.12 com1pm2AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm2BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.13 com1pm2PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm2BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.14 com1pm2RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm2BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.15 com1pm2ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm2BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.1.16 com1pm2StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm2BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2 com1pm2ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1 com1pm2ChEntry OBJECT-TYPE SYNTAX Com1pm2ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2ChSubmeterIndex } ::= { com1pm2ChTable 1 } Com1pm2ChEntry ::= SEQUENCE { com1pm2ChSubmeterIndex Integer32, com1pm2ChName OCTET STRING, com1pm2ChVoltage Opaque, com1pm2ChCurrent Opaque, com1pm2ChKW Opaque, com1pm2ChKvar Opaque, com1pm2ChKVA Opaque, com1pm2ChPF Opaque, com1pm2ChKWh Opaque, com1pm2ChKvarh Opaque, com1pm2ChKVAh Opaque, com1pm2ChActualDemand Opaque, com1pm2ChForecastDemand Opaque, com1pm2ChMaxDemandH Opaque, com1pm2ChMaxDemandD Opaque, com1pm2ChMaxDemandM Opaque, com1pm2ChElectricityD Opaque, com1pm2ChElectricityM Opaque, com1pm2ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.0 com1pm2ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm2ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.1 com1pm2ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm2ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.2 com1pm2ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm2ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.3 com1pm2ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm2ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.4 com1pm2ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm2ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.5 com1pm2ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm2ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.6 com1pm2ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm2ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.7 com1pm2ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm2ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.8 com1pm2ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm2ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.9 com1pm2ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm2ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.10 com1pm2ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm2ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.11 com1pm2ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm2ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.12 com1pm2ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm2ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.13 com1pm2ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm2ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.14 com1pm2ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm2ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.15 com1pm2ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm2ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.16 com1pm2ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm2ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.17 com1pm2ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm2ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.2.1.18 com1pm2ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm2ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3 com1pm2IOinfo OBJECT IDENTIFIER ::= { com1pm2 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.1 com1pm2DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.1.1 com1pm2DIEntry OBJECT-TYPE SYNTAX Com1pm2DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2DIIndex } ::= { com1pm2DITable 1 } Com1pm2DIEntry ::= SEQUENCE { com1pm2DIIndex Integer32, com1pm2DIName OCTET STRING, com1pm2DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.1.1.1 com1pm2DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm2DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.1.1.2 com1pm2DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm2DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.1.1.3 com1pm2DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm2DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.2 com1pm2DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.2.1 com1pm2DOEntry OBJECT-TYPE SYNTAX Com1pm2DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2DOIndex } ::= { com1pm2DOTable 1 } Com1pm2DOEntry ::= SEQUENCE { com1pm2DOIndex Integer32, com1pm2DOName OCTET STRING, com1pm2DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.2.1.1 com1pm2DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm2DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.2.1.2 com1pm2DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm2DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.2.1.3 com1pm2DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm2DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.3 com1pm2AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.3.1 com1pm2AIEntry OBJECT-TYPE SYNTAX Com1pm2AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2AIIndex } ::= { com1pm2AITable 1 } Com1pm2AIEntry ::= SEQUENCE { com1pm2AIIndex Integer32, com1pm2AIName OCTET STRING, com1pm2AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.3.1.1 com1pm2AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm2AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.3.1.2 com1pm2AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm2AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.3.1.3 com1pm2AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm2AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.4 com1pm2AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.4.1 com1pm2AOEntry OBJECT-TYPE SYNTAX Com1pm2AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2AOIndex } ::= { com1pm2AOTable 1 } Com1pm2AOEntry ::= SEQUENCE { com1pm2AOIndex Integer32, com1pm2AOName OCTET STRING, com1pm2AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.4.1.1 com1pm2AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm2AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.4.1.2 com1pm2AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm2AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.3.4.1.3 com1pm2AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm2AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.4 com1pm2HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm2HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm2 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.4.1 com1pm2HarmonicEntry OBJECT-TYPE SYNTAX Com1pm2HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm2HarmonicSubmeterIndex } ::= { com1pm2HarmonicTable 1 } Com1pm2HarmonicEntry ::= SEQUENCE { com1pm2HarmonicSubmeterIndex Integer32, com1pm2HarmonicSelector Integer32, com1pm2HarmonicVTHD Opaque, com1pm2HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.4.1.1 com1pm2HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm2HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.4.1.2 com1pm2HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm2HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.4.1.3 com1pm2HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm2HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.2.4.1.4 com1pm2HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm2HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3 com1pm3 OBJECT IDENTIFIER ::= { com1pm 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1 com1pm3BasicInfo OBJECT IDENTIFIER ::= { com1pm3 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.1 com1pm3Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm3BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.2 com1pm3Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm3BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.3 com1pm3ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm3BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.4 com1pm3Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm3BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.5 com1pm3PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.5.1 com1pm3PtEntry OBJECT-TYPE SYNTAX Com1pm3PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3PtIndex } ::= { com1pm3PtTable 1 } Com1pm3PtEntry ::= SEQUENCE { com1pm3PtIndex Integer32, com1pm3PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.5.1.1 com1pm3PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm3PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.5.1.2 com1pm3PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm3PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.6 com1pm3CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.6.1 com1pm3CtEntry OBJECT-TYPE SYNTAX Com1pm3CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3CtIndex } ::= { com1pm3CtTable 1 } Com1pm3CtEntry ::= SEQUENCE { com1pm3CtIndex Integer32, com1pm3CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.6.1.1 com1pm3CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm3CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.6.1.2 com1pm3CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm3CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.9 com1pm3DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm3BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.10 com1pm3DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm3BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.11 com1pm3AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm3BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.12 com1pm3AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm3BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.13 com1pm3PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm3BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.14 com1pm3RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm3BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.15 com1pm3ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm3BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.1.16 com1pm3StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm3BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2 com1pm3ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1 com1pm3ChEntry OBJECT-TYPE SYNTAX Com1pm3ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3ChSubmeterIndex } ::= { com1pm3ChTable 1 } Com1pm3ChEntry ::= SEQUENCE { com1pm3ChSubmeterIndex Integer32, com1pm3ChName OCTET STRING, com1pm3ChVoltage Opaque, com1pm3ChCurrent Opaque, com1pm3ChKW Opaque, com1pm3ChKvar Opaque, com1pm3ChKVA Opaque, com1pm3ChPF Opaque, com1pm3ChKWh Opaque, com1pm3ChKvarh Opaque, com1pm3ChKVAh Opaque, com1pm3ChActualDemand Opaque, com1pm3ChForecastDemand Opaque, com1pm3ChMaxDemandH Opaque, com1pm3ChMaxDemandD Opaque, com1pm3ChMaxDemandM Opaque, com1pm3ChElectricityD Opaque, com1pm3ChElectricityM Opaque, com1pm3ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.0 com1pm3ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm3ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.1 com1pm3ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm3ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.2 com1pm3ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm3ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.3 com1pm3ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm3ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.4 com1pm3ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm3ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.5 com1pm3ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm3ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.6 com1pm3ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm3ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.7 com1pm3ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm3ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.8 com1pm3ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm3ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.9 com1pm3ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm3ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.10 com1pm3ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm3ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.11 com1pm3ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm3ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.12 com1pm3ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm3ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.13 com1pm3ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm3ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.14 com1pm3ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm3ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.15 com1pm3ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm3ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.16 com1pm3ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm3ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.17 com1pm3ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm3ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.2.1.18 com1pm3ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm3ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3 com1pm3IOinfo OBJECT IDENTIFIER ::= { com1pm3 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.1 com1pm3DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.1.1 com1pm3DIEntry OBJECT-TYPE SYNTAX Com1pm3DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3DIIndex } ::= { com1pm3DITable 1 } Com1pm3DIEntry ::= SEQUENCE { com1pm3DIIndex Integer32, com1pm3DIName OCTET STRING, com1pm3DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.1.1.1 com1pm3DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm3DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.1.1.2 com1pm3DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm3DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.1.1.3 com1pm3DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm3DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.2 com1pm3DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.2.1 com1pm3DOEntry OBJECT-TYPE SYNTAX Com1pm3DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3DOIndex } ::= { com1pm3DOTable 1 } Com1pm3DOEntry ::= SEQUENCE { com1pm3DOIndex Integer32, com1pm3DOName OCTET STRING, com1pm3DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.2.1.1 com1pm3DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm3DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.2.1.2 com1pm3DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm3DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.2.1.3 com1pm3DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm3DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.3 com1pm3AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.3.1 com1pm3AIEntry OBJECT-TYPE SYNTAX Com1pm3AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3AIIndex } ::= { com1pm3AITable 1 } Com1pm3AIEntry ::= SEQUENCE { com1pm3AIIndex Integer32, com1pm3AIName OCTET STRING, com1pm3AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.3.1.1 com1pm3AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm3AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.3.1.2 com1pm3AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm3AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.3.1.3 com1pm3AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm3AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.4 com1pm3AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.4.1 com1pm3AOEntry OBJECT-TYPE SYNTAX Com1pm3AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3AOIndex } ::= { com1pm3AOTable 1 } Com1pm3AOEntry ::= SEQUENCE { com1pm3AOIndex Integer32, com1pm3AOName OCTET STRING, com1pm3AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.4.1.1 com1pm3AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm3AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.4.1.2 com1pm3AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm3AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.3.4.1.3 com1pm3AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm3AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.4 com1pm3HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm3HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm3 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.4.1 com1pm3HarmonicEntry OBJECT-TYPE SYNTAX Com1pm3HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm3HarmonicSubmeterIndex } ::= { com1pm3HarmonicTable 1 } Com1pm3HarmonicEntry ::= SEQUENCE { com1pm3HarmonicSubmeterIndex Integer32, com1pm3HarmonicSelector Integer32, com1pm3HarmonicVTHD Opaque, com1pm3HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.4.1.1 com1pm3HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm3HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.4.1.2 com1pm3HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm3HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.4.1.3 com1pm3HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm3HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.3.4.1.4 com1pm3HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm3HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4 com1pm4 OBJECT IDENTIFIER ::= { com1pm 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1 com1pm4BasicInfo OBJECT IDENTIFIER ::= { com1pm4 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.1 com1pm4Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm4BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.2 com1pm4Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm4BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.3 com1pm4ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm4BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.4 com1pm4Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm4BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.5 com1pm4PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.5.1 com1pm4PtEntry OBJECT-TYPE SYNTAX Com1pm4PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4PtIndex } ::= { com1pm4PtTable 1 } Com1pm4PtEntry ::= SEQUENCE { com1pm4PtIndex Integer32, com1pm4PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.5.1.1 com1pm4PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm4PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.5.1.2 com1pm4PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm4PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.6 com1pm4CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.6.1 com1pm4CtEntry OBJECT-TYPE SYNTAX Com1pm4CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4CtIndex } ::= { com1pm4CtTable 1 } Com1pm4CtEntry ::= SEQUENCE { com1pm4CtIndex Integer32, com1pm4CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.6.1.1 com1pm4CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm4CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.6.1.2 com1pm4CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm4CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.9 com1pm4DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm4BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.10 com1pm4DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm4BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.11 com1pm4AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm4BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.12 com1pm4AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm4BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.13 com1pm4PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm4BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.14 com1pm4RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm4BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.15 com1pm4ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm4BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.1.16 com1pm4StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm4BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2 com1pm4ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1 com1pm4ChEntry OBJECT-TYPE SYNTAX Com1pm4ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4ChSubmeterIndex } ::= { com1pm4ChTable 1 } Com1pm4ChEntry ::= SEQUENCE { com1pm4ChSubmeterIndex Integer32, com1pm4ChName OCTET STRING, com1pm4ChVoltage Opaque, com1pm4ChCurrent Opaque, com1pm4ChKW Opaque, com1pm4ChKvar Opaque, com1pm4ChKVA Opaque, com1pm4ChPF Opaque, com1pm4ChKWh Opaque, com1pm4ChKvarh Opaque, com1pm4ChKVAh Opaque, com1pm4ChActualDemand Opaque, com1pm4ChForecastDemand Opaque, com1pm4ChMaxDemandH Opaque, com1pm4ChMaxDemandD Opaque, com1pm4ChMaxDemandM Opaque, com1pm4ChElectricityD Opaque, com1pm4ChElectricityM Opaque, com1pm4ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.0 com1pm4ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm4ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.1 com1pm4ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm4ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.2 com1pm4ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm4ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.3 com1pm4ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm4ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.4 com1pm4ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm4ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.5 com1pm4ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm4ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.6 com1pm4ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm4ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.7 com1pm4ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm4ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.8 com1pm4ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm4ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.9 com1pm4ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm4ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.10 com1pm4ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm4ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.11 com1pm4ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm4ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.12 com1pm4ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm4ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.13 com1pm4ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm4ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.14 com1pm4ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm4ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.15 com1pm4ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm4ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.16 com1pm4ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm4ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.17 com1pm4ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm4ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.2.1.18 com1pm4ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm4ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3 com1pm4IOinfo OBJECT IDENTIFIER ::= { com1pm4 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.1 com1pm4DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.1.1 com1pm4DIEntry OBJECT-TYPE SYNTAX Com1pm4DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4DIIndex } ::= { com1pm4DITable 1 } Com1pm4DIEntry ::= SEQUENCE { com1pm4DIIndex Integer32, com1pm4DIName OCTET STRING, com1pm4DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.1.1.1 com1pm4DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm4DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.1.1.2 com1pm4DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm4DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.1.1.3 com1pm4DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm4DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.2 com1pm4DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.2.1 com1pm4DOEntry OBJECT-TYPE SYNTAX Com1pm4DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4DOIndex } ::= { com1pm4DOTable 1 } Com1pm4DOEntry ::= SEQUENCE { com1pm4DOIndex Integer32, com1pm4DOName OCTET STRING, com1pm4DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.2.1.1 com1pm4DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm4DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.2.1.2 com1pm4DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm4DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.2.1.3 com1pm4DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm4DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.3 com1pm4AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.3.1 com1pm4AIEntry OBJECT-TYPE SYNTAX Com1pm4AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4AIIndex } ::= { com1pm4AITable 1 } Com1pm4AIEntry ::= SEQUENCE { com1pm4AIIndex Integer32, com1pm4AIName OCTET STRING, com1pm4AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.3.1.1 com1pm4AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm4AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.3.1.2 com1pm4AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm4AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.3.1.3 com1pm4AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm4AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.4 com1pm4AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.4.1 com1pm4AOEntry OBJECT-TYPE SYNTAX Com1pm4AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4AOIndex } ::= { com1pm4AOTable 1 } Com1pm4AOEntry ::= SEQUENCE { com1pm4AOIndex Integer32, com1pm4AOName OCTET STRING, com1pm4AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.4.1.1 com1pm4AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm4AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.4.1.2 com1pm4AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm4AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.3.4.1.3 com1pm4AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm4AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.4 com1pm4HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm4HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm4 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.4.1 com1pm4HarmonicEntry OBJECT-TYPE SYNTAX Com1pm4HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm4HarmonicSubmeterIndex } ::= { com1pm4HarmonicTable 1 } Com1pm4HarmonicEntry ::= SEQUENCE { com1pm4HarmonicSubmeterIndex Integer32, com1pm4HarmonicSelector Integer32, com1pm4HarmonicVTHD Opaque, com1pm4HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.4.1.1 com1pm4HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm4HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.4.1.2 com1pm4HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm4HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.4.1.3 com1pm4HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm4HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.4.4.1.4 com1pm4HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm4HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5 com1pm5 OBJECT IDENTIFIER ::= { com1pm 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1 com1pm5BasicInfo OBJECT IDENTIFIER ::= { com1pm5 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.1 com1pm5Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm5BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.2 com1pm5Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm5BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.3 com1pm5ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm5BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.4 com1pm5Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm5BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.5 com1pm5PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.5.1 com1pm5PtEntry OBJECT-TYPE SYNTAX Com1pm5PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5PtIndex } ::= { com1pm5PtTable 1 } Com1pm5PtEntry ::= SEQUENCE { com1pm5PtIndex Integer32, com1pm5PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.5.1.1 com1pm5PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm5PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.5.1.2 com1pm5PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm5PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.6 com1pm5CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.6.1 com1pm5CtEntry OBJECT-TYPE SYNTAX Com1pm5CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5CtIndex } ::= { com1pm5CtTable 1 } Com1pm5CtEntry ::= SEQUENCE { com1pm5CtIndex Integer32, com1pm5CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.6.1.1 com1pm5CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm5CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.6.1.2 com1pm5CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm5CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.9 com1pm5DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm5BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.10 com1pm5DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm5BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.11 com1pm5AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm5BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.12 com1pm5AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm5BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.13 com1pm5PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm5BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.14 com1pm5RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm5BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.15 com1pm5ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm5BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.1.16 com1pm5StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm5BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2 com1pm5ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1 com1pm5ChEntry OBJECT-TYPE SYNTAX Com1pm5ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5ChSubmeterIndex } ::= { com1pm5ChTable 1 } Com1pm5ChEntry ::= SEQUENCE { com1pm5ChSubmeterIndex Integer32, com1pm5ChName OCTET STRING, com1pm5ChVoltage Opaque, com1pm5ChCurrent Opaque, com1pm5ChKW Opaque, com1pm5ChKvar Opaque, com1pm5ChKVA Opaque, com1pm5ChPF Opaque, com1pm5ChKWh Opaque, com1pm5ChKvarh Opaque, com1pm5ChKVAh Opaque, com1pm5ChActualDemand Opaque, com1pm5ChForecastDemand Opaque, com1pm5ChMaxDemandH Opaque, com1pm5ChMaxDemandD Opaque, com1pm5ChMaxDemandM Opaque, com1pm5ChElectricityD Opaque, com1pm5ChElectricityM Opaque, com1pm5ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.0 com1pm5ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm5ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.1 com1pm5ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm5ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.2 com1pm5ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm5ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.3 com1pm5ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm5ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.4 com1pm5ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm5ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.5 com1pm5ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm5ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.6 com1pm5ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm5ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.7 com1pm5ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm5ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.8 com1pm5ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm5ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.9 com1pm5ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm5ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.10 com1pm5ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm5ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.11 com1pm5ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm5ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.12 com1pm5ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm5ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.13 com1pm5ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm5ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.14 com1pm5ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm5ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.15 com1pm5ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm5ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.16 com1pm5ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm5ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.17 com1pm5ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm5ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.2.1.18 com1pm5ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm5ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3 com1pm5IOinfo OBJECT IDENTIFIER ::= { com1pm5 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.1 com1pm5DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.1.1 com1pm5DIEntry OBJECT-TYPE SYNTAX Com1pm5DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5DIIndex } ::= { com1pm5DITable 1 } Com1pm5DIEntry ::= SEQUENCE { com1pm5DIIndex Integer32, com1pm5DIName OCTET STRING, com1pm5DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.1.1.1 com1pm5DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm5DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.1.1.2 com1pm5DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm5DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.1.1.3 com1pm5DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm5DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.2 com1pm5DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.2.1 com1pm5DOEntry OBJECT-TYPE SYNTAX Com1pm5DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5DOIndex } ::= { com1pm5DOTable 1 } Com1pm5DOEntry ::= SEQUENCE { com1pm5DOIndex Integer32, com1pm5DOName OCTET STRING, com1pm5DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.2.1.1 com1pm5DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm5DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.2.1.2 com1pm5DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm5DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.2.1.3 com1pm5DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm5DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.3 com1pm5AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.3.1 com1pm5AIEntry OBJECT-TYPE SYNTAX Com1pm5AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5AIIndex } ::= { com1pm5AITable 1 } Com1pm5AIEntry ::= SEQUENCE { com1pm5AIIndex Integer32, com1pm5AIName OCTET STRING, com1pm5AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.3.1.1 com1pm5AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm5AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.3.1.2 com1pm5AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm5AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.3.1.3 com1pm5AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm5AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.4 com1pm5AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.4.1 com1pm5AOEntry OBJECT-TYPE SYNTAX Com1pm5AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5AOIndex } ::= { com1pm5AOTable 1 } Com1pm5AOEntry ::= SEQUENCE { com1pm5AOIndex Integer32, com1pm5AOName OCTET STRING, com1pm5AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.4.1.1 com1pm5AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm5AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.4.1.2 com1pm5AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm5AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.3.4.1.3 com1pm5AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm5AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.4 com1pm5HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm5HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm5 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.4.1 com1pm5HarmonicEntry OBJECT-TYPE SYNTAX Com1pm5HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm5HarmonicSubmeterIndex } ::= { com1pm5HarmonicTable 1 } Com1pm5HarmonicEntry ::= SEQUENCE { com1pm5HarmonicSubmeterIndex Integer32, com1pm5HarmonicSelector Integer32, com1pm5HarmonicVTHD Opaque, com1pm5HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.4.1.1 com1pm5HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm5HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.4.1.2 com1pm5HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm5HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.4.1.3 com1pm5HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm5HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.5.4.1.4 com1pm5HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm5HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6 com1pm6 OBJECT IDENTIFIER ::= { com1pm 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1 com1pm6BasicInfo OBJECT IDENTIFIER ::= { com1pm6 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.1 com1pm6Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm6BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.2 com1pm6Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm6BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.3 com1pm6ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm6BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.4 com1pm6Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm6BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.5 com1pm6PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.5.1 com1pm6PtEntry OBJECT-TYPE SYNTAX Com1pm6PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6PtIndex } ::= { com1pm6PtTable 1 } Com1pm6PtEntry ::= SEQUENCE { com1pm6PtIndex Integer32, com1pm6PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.5.1.1 com1pm6PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm6PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.5.1.2 com1pm6PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm6PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.6 com1pm6CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.6.1 com1pm6CtEntry OBJECT-TYPE SYNTAX Com1pm6CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6CtIndex } ::= { com1pm6CtTable 1 } Com1pm6CtEntry ::= SEQUENCE { com1pm6CtIndex Integer32, com1pm6CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.6.1.1 com1pm6CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm6CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.6.1.2 com1pm6CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm6CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.9 com1pm6DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm6BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.10 com1pm6DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm6BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.11 com1pm6AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm6BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.12 com1pm6AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm6BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.13 com1pm6PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm6BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.14 com1pm6RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm6BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.15 com1pm6ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm6BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.1.16 com1pm6StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm6BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2 com1pm6ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1 com1pm6ChEntry OBJECT-TYPE SYNTAX Com1pm6ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6ChSubmeterIndex } ::= { com1pm6ChTable 1 } Com1pm6ChEntry ::= SEQUENCE { com1pm6ChSubmeterIndex Integer32, com1pm6ChName OCTET STRING, com1pm6ChVoltage Opaque, com1pm6ChCurrent Opaque, com1pm6ChKW Opaque, com1pm6ChKvar Opaque, com1pm6ChKVA Opaque, com1pm6ChPF Opaque, com1pm6ChKWh Opaque, com1pm6ChKvarh Opaque, com1pm6ChKVAh Opaque, com1pm6ChActualDemand Opaque, com1pm6ChForecastDemand Opaque, com1pm6ChMaxDemandH Opaque, com1pm6ChMaxDemandD Opaque, com1pm6ChMaxDemandM Opaque, com1pm6ChElectricityD Opaque, com1pm6ChElectricityM Opaque, com1pm6ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.0 com1pm6ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm6ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.1 com1pm6ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm6ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.2 com1pm6ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm6ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.3 com1pm6ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm6ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.4 com1pm6ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm6ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.5 com1pm6ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm6ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.6 com1pm6ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm6ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.7 com1pm6ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm6ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.8 com1pm6ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm6ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.9 com1pm6ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm6ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.10 com1pm6ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm6ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.11 com1pm6ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm6ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.12 com1pm6ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm6ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.13 com1pm6ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm6ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.14 com1pm6ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm6ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.15 com1pm6ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm6ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.16 com1pm6ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm6ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.17 com1pm6ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm6ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.2.1.18 com1pm6ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm6ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3 com1pm6IOinfo OBJECT IDENTIFIER ::= { com1pm6 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.1 com1pm6DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.1.1 com1pm6DIEntry OBJECT-TYPE SYNTAX Com1pm6DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6DIIndex } ::= { com1pm6DITable 1 } Com1pm6DIEntry ::= SEQUENCE { com1pm6DIIndex Integer32, com1pm6DIName OCTET STRING, com1pm6DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.1.1.1 com1pm6DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm6DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.1.1.2 com1pm6DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm6DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.1.1.3 com1pm6DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm6DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.2 com1pm6DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.2.1 com1pm6DOEntry OBJECT-TYPE SYNTAX Com1pm6DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6DOIndex } ::= { com1pm6DOTable 1 } Com1pm6DOEntry ::= SEQUENCE { com1pm6DOIndex Integer32, com1pm6DOName OCTET STRING, com1pm6DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.2.1.1 com1pm6DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm6DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.2.1.2 com1pm6DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm6DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.2.1.3 com1pm6DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm6DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.3 com1pm6AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.3.1 com1pm6AIEntry OBJECT-TYPE SYNTAX Com1pm6AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6AIIndex } ::= { com1pm6AITable 1 } Com1pm6AIEntry ::= SEQUENCE { com1pm6AIIndex Integer32, com1pm6AIName OCTET STRING, com1pm6AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.3.1.1 com1pm6AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm6AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.3.1.2 com1pm6AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm6AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.3.1.3 com1pm6AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm6AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.4 com1pm6AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.4.1 com1pm6AOEntry OBJECT-TYPE SYNTAX Com1pm6AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6AOIndex } ::= { com1pm6AOTable 1 } Com1pm6AOEntry ::= SEQUENCE { com1pm6AOIndex Integer32, com1pm6AOName OCTET STRING, com1pm6AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.4.1.1 com1pm6AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm6AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.4.1.2 com1pm6AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm6AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.3.4.1.3 com1pm6AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm6AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.4 com1pm6HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm6HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm6 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.4.1 com1pm6HarmonicEntry OBJECT-TYPE SYNTAX Com1pm6HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm6HarmonicSubmeterIndex } ::= { com1pm6HarmonicTable 1 } Com1pm6HarmonicEntry ::= SEQUENCE { com1pm6HarmonicSubmeterIndex Integer32, com1pm6HarmonicSelector Integer32, com1pm6HarmonicVTHD Opaque, com1pm6HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.4.1.1 com1pm6HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm6HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.4.1.2 com1pm6HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm6HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.4.1.3 com1pm6HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm6HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.6.4.1.4 com1pm6HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm6HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7 com1pm7 OBJECT IDENTIFIER ::= { com1pm 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1 com1pm7BasicInfo OBJECT IDENTIFIER ::= { com1pm7 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.1 com1pm7Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm7BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.2 com1pm7Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm7BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.3 com1pm7ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm7BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.4 com1pm7Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm7BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.5 com1pm7PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.5.1 com1pm7PtEntry OBJECT-TYPE SYNTAX Com1pm7PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7PtIndex } ::= { com1pm7PtTable 1 } Com1pm7PtEntry ::= SEQUENCE { com1pm7PtIndex Integer32, com1pm7PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.5.1.1 com1pm7PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm7PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.5.1.2 com1pm7PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm7PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.6 com1pm7CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.6.1 com1pm7CtEntry OBJECT-TYPE SYNTAX Com1pm7CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7CtIndex } ::= { com1pm7CtTable 1 } Com1pm7CtEntry ::= SEQUENCE { com1pm7CtIndex Integer32, com1pm7CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.6.1.1 com1pm7CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm7CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.6.1.2 com1pm7CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm7CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.9 com1pm7DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm7BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.10 com1pm7DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm7BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.11 com1pm7AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm7BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.12 com1pm7AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm7BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.13 com1pm7PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm7BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.14 com1pm7RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm7BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.15 com1pm7ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm7BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.1.16 com1pm7StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm7BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2 com1pm7ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1 com1pm7ChEntry OBJECT-TYPE SYNTAX Com1pm7ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7ChSubmeterIndex } ::= { com1pm7ChTable 1 } Com1pm7ChEntry ::= SEQUENCE { com1pm7ChSubmeterIndex Integer32, com1pm7ChName OCTET STRING, com1pm7ChVoltage Opaque, com1pm7ChCurrent Opaque, com1pm7ChKW Opaque, com1pm7ChKvar Opaque, com1pm7ChKVA Opaque, com1pm7ChPF Opaque, com1pm7ChKWh Opaque, com1pm7ChKvarh Opaque, com1pm7ChKVAh Opaque, com1pm7ChActualDemand Opaque, com1pm7ChForecastDemand Opaque, com1pm7ChMaxDemandH Opaque, com1pm7ChMaxDemandD Opaque, com1pm7ChMaxDemandM Opaque, com1pm7ChElectricityD Opaque, com1pm7ChElectricityM Opaque, com1pm7ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.0 com1pm7ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm7ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.1 com1pm7ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm7ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.2 com1pm7ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm7ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.3 com1pm7ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm7ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.4 com1pm7ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm7ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.5 com1pm7ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm7ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.6 com1pm7ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm7ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.7 com1pm7ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm7ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.8 com1pm7ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm7ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.9 com1pm7ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm7ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.10 com1pm7ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm7ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.11 com1pm7ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm7ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.12 com1pm7ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm7ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.13 com1pm7ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm7ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.14 com1pm7ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm7ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.15 com1pm7ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm7ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.16 com1pm7ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm7ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.17 com1pm7ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm7ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.2.1.18 com1pm7ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm7ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3 com1pm7IOinfo OBJECT IDENTIFIER ::= { com1pm7 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.1 com1pm7DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.1.1 com1pm7DIEntry OBJECT-TYPE SYNTAX Com1pm7DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7DIIndex } ::= { com1pm7DITable 1 } Com1pm7DIEntry ::= SEQUENCE { com1pm7DIIndex Integer32, com1pm7DIName OCTET STRING, com1pm7DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.1.1.1 com1pm7DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm7DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.1.1.2 com1pm7DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm7DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.1.1.3 com1pm7DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm7DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.2 com1pm7DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.2.1 com1pm7DOEntry OBJECT-TYPE SYNTAX Com1pm7DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7DOIndex } ::= { com1pm7DOTable 1 } Com1pm7DOEntry ::= SEQUENCE { com1pm7DOIndex Integer32, com1pm7DOName OCTET STRING, com1pm7DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.2.1.1 com1pm7DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm7DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.2.1.2 com1pm7DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm7DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.2.1.3 com1pm7DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm7DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.3 com1pm7AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.3.1 com1pm7AIEntry OBJECT-TYPE SYNTAX Com1pm7AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7AIIndex } ::= { com1pm7AITable 1 } Com1pm7AIEntry ::= SEQUENCE { com1pm7AIIndex Integer32, com1pm7AIName OCTET STRING, com1pm7AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.3.1.1 com1pm7AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm7AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.3.1.2 com1pm7AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm7AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.3.1.3 com1pm7AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm7AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.4 com1pm7AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.4.1 com1pm7AOEntry OBJECT-TYPE SYNTAX Com1pm7AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7AOIndex } ::= { com1pm7AOTable 1 } Com1pm7AOEntry ::= SEQUENCE { com1pm7AOIndex Integer32, com1pm7AOName OCTET STRING, com1pm7AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.4.1.1 com1pm7AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm7AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.4.1.2 com1pm7AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm7AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.3.4.1.3 com1pm7AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm7AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.4 com1pm7HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm7HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm7 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.4.1 com1pm7HarmonicEntry OBJECT-TYPE SYNTAX Com1pm7HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm7HarmonicSubmeterIndex } ::= { com1pm7HarmonicTable 1 } Com1pm7HarmonicEntry ::= SEQUENCE { com1pm7HarmonicSubmeterIndex Integer32, com1pm7HarmonicSelector Integer32, com1pm7HarmonicVTHD Opaque, com1pm7HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.4.1.1 com1pm7HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm7HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.4.1.2 com1pm7HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm7HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.4.1.3 com1pm7HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm7HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.7.4.1.4 com1pm7HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm7HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8 com1pm8 OBJECT IDENTIFIER ::= { com1pm 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1 com1pm8BasicInfo OBJECT IDENTIFIER ::= { com1pm8 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.1 com1pm8Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm8BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.2 com1pm8Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm8BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.3 com1pm8ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm8BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.4 com1pm8Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm8BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.5 com1pm8PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.5.1 com1pm8PtEntry OBJECT-TYPE SYNTAX Com1pm8PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8PtIndex } ::= { com1pm8PtTable 1 } Com1pm8PtEntry ::= SEQUENCE { com1pm8PtIndex Integer32, com1pm8PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.5.1.1 com1pm8PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm8PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.5.1.2 com1pm8PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm8PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.6 com1pm8CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.6.1 com1pm8CtEntry OBJECT-TYPE SYNTAX Com1pm8CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8CtIndex } ::= { com1pm8CtTable 1 } Com1pm8CtEntry ::= SEQUENCE { com1pm8CtIndex Integer32, com1pm8CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.6.1.1 com1pm8CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm8CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.6.1.2 com1pm8CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm8CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.9 com1pm8DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm8BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.10 com1pm8DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm8BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.11 com1pm8AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm8BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.12 com1pm8AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm8BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.13 com1pm8PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm8BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.14 com1pm8RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm8BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.15 com1pm8ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm8BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.1.16 com1pm8StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm8BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2 com1pm8ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1 com1pm8ChEntry OBJECT-TYPE SYNTAX Com1pm8ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8ChSubmeterIndex } ::= { com1pm8ChTable 1 } Com1pm8ChEntry ::= SEQUENCE { com1pm8ChSubmeterIndex Integer32, com1pm8ChName OCTET STRING, com1pm8ChVoltage Opaque, com1pm8ChCurrent Opaque, com1pm8ChKW Opaque, com1pm8ChKvar Opaque, com1pm8ChKVA Opaque, com1pm8ChPF Opaque, com1pm8ChKWh Opaque, com1pm8ChKvarh Opaque, com1pm8ChKVAh Opaque, com1pm8ChActualDemand Opaque, com1pm8ChForecastDemand Opaque, com1pm8ChMaxDemandH Opaque, com1pm8ChMaxDemandD Opaque, com1pm8ChMaxDemandM Opaque, com1pm8ChElectricityD Opaque, com1pm8ChElectricityM Opaque, com1pm8ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.0 com1pm8ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm8ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.1 com1pm8ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm8ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.2 com1pm8ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm8ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.3 com1pm8ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm8ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.4 com1pm8ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm8ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.5 com1pm8ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm8ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.6 com1pm8ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm8ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.7 com1pm8ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm8ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.8 com1pm8ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm8ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.9 com1pm8ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm8ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.10 com1pm8ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm8ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.11 com1pm8ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm8ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.12 com1pm8ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm8ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.13 com1pm8ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm8ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.14 com1pm8ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm8ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.15 com1pm8ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm8ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.16 com1pm8ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm8ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.17 com1pm8ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm8ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.2.1.18 com1pm8ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm8ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3 com1pm8IOinfo OBJECT IDENTIFIER ::= { com1pm8 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.1 com1pm8DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.1.1 com1pm8DIEntry OBJECT-TYPE SYNTAX Com1pm8DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8DIIndex } ::= { com1pm8DITable 1 } Com1pm8DIEntry ::= SEQUENCE { com1pm8DIIndex Integer32, com1pm8DIName OCTET STRING, com1pm8DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.1.1.1 com1pm8DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm8DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.1.1.2 com1pm8DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm8DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.1.1.3 com1pm8DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm8DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.2 com1pm8DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.2.1 com1pm8DOEntry OBJECT-TYPE SYNTAX Com1pm8DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8DOIndex } ::= { com1pm8DOTable 1 } Com1pm8DOEntry ::= SEQUENCE { com1pm8DOIndex Integer32, com1pm8DOName OCTET STRING, com1pm8DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.2.1.1 com1pm8DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm8DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.2.1.2 com1pm8DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm8DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.2.1.3 com1pm8DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm8DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.3 com1pm8AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.3.1 com1pm8AIEntry OBJECT-TYPE SYNTAX Com1pm8AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8AIIndex } ::= { com1pm8AITable 1 } Com1pm8AIEntry ::= SEQUENCE { com1pm8AIIndex Integer32, com1pm8AIName OCTET STRING, com1pm8AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.3.1.1 com1pm8AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm8AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.3.1.2 com1pm8AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm8AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.3.1.3 com1pm8AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm8AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.4 com1pm8AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.4.1 com1pm8AOEntry OBJECT-TYPE SYNTAX Com1pm8AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8AOIndex } ::= { com1pm8AOTable 1 } Com1pm8AOEntry ::= SEQUENCE { com1pm8AOIndex Integer32, com1pm8AOName OCTET STRING, com1pm8AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.4.1.1 com1pm8AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm8AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.4.1.2 com1pm8AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm8AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.3.4.1.3 com1pm8AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm8AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.4 com1pm8HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm8HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm8 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.4.1 com1pm8HarmonicEntry OBJECT-TYPE SYNTAX Com1pm8HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm8HarmonicSubmeterIndex } ::= { com1pm8HarmonicTable 1 } Com1pm8HarmonicEntry ::= SEQUENCE { com1pm8HarmonicSubmeterIndex Integer32, com1pm8HarmonicSelector Integer32, com1pm8HarmonicVTHD Opaque, com1pm8HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.4.1.1 com1pm8HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm8HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.4.1.2 com1pm8HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm8HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.4.1.3 com1pm8HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm8HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.8.4.1.4 com1pm8HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm8HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9 com1pm9 OBJECT IDENTIFIER ::= { com1pm 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1 com1pm9BasicInfo OBJECT IDENTIFIER ::= { com1pm9 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.1 com1pm9Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm9BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.2 com1pm9Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm9BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.3 com1pm9ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm9BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.4 com1pm9Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm9BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.5 com1pm9PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.5.1 com1pm9PtEntry OBJECT-TYPE SYNTAX Com1pm9PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9PtIndex } ::= { com1pm9PtTable 1 } Com1pm9PtEntry ::= SEQUENCE { com1pm9PtIndex Integer32, com1pm9PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.5.1.1 com1pm9PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm9PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.5.1.2 com1pm9PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm9PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.6 com1pm9CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.6.1 com1pm9CtEntry OBJECT-TYPE SYNTAX Com1pm9CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9CtIndex } ::= { com1pm9CtTable 1 } Com1pm9CtEntry ::= SEQUENCE { com1pm9CtIndex Integer32, com1pm9CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.6.1.1 com1pm9CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm9CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.6.1.2 com1pm9CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm9CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.9 com1pm9DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm9BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.10 com1pm9DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm9BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.11 com1pm9AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm9BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.12 com1pm9AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm9BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.13 com1pm9PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm9BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.14 com1pm9RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm9BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.15 com1pm9ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm9BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.1.16 com1pm9StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm9BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2 com1pm9ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1 com1pm9ChEntry OBJECT-TYPE SYNTAX Com1pm9ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9ChSubmeterIndex } ::= { com1pm9ChTable 1 } Com1pm9ChEntry ::= SEQUENCE { com1pm9ChSubmeterIndex Integer32, com1pm9ChName OCTET STRING, com1pm9ChVoltage Opaque, com1pm9ChCurrent Opaque, com1pm9ChKW Opaque, com1pm9ChKvar Opaque, com1pm9ChKVA Opaque, com1pm9ChPF Opaque, com1pm9ChKWh Opaque, com1pm9ChKvarh Opaque, com1pm9ChKVAh Opaque, com1pm9ChActualDemand Opaque, com1pm9ChForecastDemand Opaque, com1pm9ChMaxDemandH Opaque, com1pm9ChMaxDemandD Opaque, com1pm9ChMaxDemandM Opaque, com1pm9ChElectricityD Opaque, com1pm9ChElectricityM Opaque, com1pm9ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.0 com1pm9ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm9ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.1 com1pm9ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm9ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.2 com1pm9ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm9ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.3 com1pm9ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm9ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.4 com1pm9ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm9ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.5 com1pm9ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm9ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.6 com1pm9ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm9ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.7 com1pm9ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm9ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.8 com1pm9ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm9ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.9 com1pm9ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm9ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.10 com1pm9ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm9ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.11 com1pm9ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm9ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.12 com1pm9ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm9ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.13 com1pm9ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm9ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.14 com1pm9ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm9ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.15 com1pm9ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm9ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.16 com1pm9ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm9ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.17 com1pm9ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm9ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.2.1.18 com1pm9ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm9ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3 com1pm9IOinfo OBJECT IDENTIFIER ::= { com1pm9 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.1 com1pm9DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.1.1 com1pm9DIEntry OBJECT-TYPE SYNTAX Com1pm9DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9DIIndex } ::= { com1pm9DITable 1 } Com1pm9DIEntry ::= SEQUENCE { com1pm9DIIndex Integer32, com1pm9DIName OCTET STRING, com1pm9DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.1.1.1 com1pm9DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm9DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.1.1.2 com1pm9DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm9DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.1.1.3 com1pm9DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm9DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.2 com1pm9DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.2.1 com1pm9DOEntry OBJECT-TYPE SYNTAX Com1pm9DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9DOIndex } ::= { com1pm9DOTable 1 } Com1pm9DOEntry ::= SEQUENCE { com1pm9DOIndex Integer32, com1pm9DOName OCTET STRING, com1pm9DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.2.1.1 com1pm9DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm9DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.2.1.2 com1pm9DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm9DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.2.1.3 com1pm9DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm9DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.3 com1pm9AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.3.1 com1pm9AIEntry OBJECT-TYPE SYNTAX Com1pm9AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9AIIndex } ::= { com1pm9AITable 1 } Com1pm9AIEntry ::= SEQUENCE { com1pm9AIIndex Integer32, com1pm9AIName OCTET STRING, com1pm9AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.3.1.1 com1pm9AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm9AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.3.1.2 com1pm9AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm9AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.3.1.3 com1pm9AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm9AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.4 com1pm9AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.4.1 com1pm9AOEntry OBJECT-TYPE SYNTAX Com1pm9AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9AOIndex } ::= { com1pm9AOTable 1 } Com1pm9AOEntry ::= SEQUENCE { com1pm9AOIndex Integer32, com1pm9AOName OCTET STRING, com1pm9AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.4.1.1 com1pm9AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm9AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.4.1.2 com1pm9AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm9AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.3.4.1.3 com1pm9AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm9AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.4 com1pm9HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm9HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm9 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.4.1 com1pm9HarmonicEntry OBJECT-TYPE SYNTAX Com1pm9HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm9HarmonicSubmeterIndex } ::= { com1pm9HarmonicTable 1 } Com1pm9HarmonicEntry ::= SEQUENCE { com1pm9HarmonicSubmeterIndex Integer32, com1pm9HarmonicSelector Integer32, com1pm9HarmonicVTHD Opaque, com1pm9HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.4.1.1 com1pm9HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm9HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.4.1.2 com1pm9HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm9HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.4.1.3 com1pm9HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm9HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.9.4.1.4 com1pm9HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm9HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10 com1pm10 OBJECT IDENTIFIER ::= { com1pm 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1 com1pm10BasicInfo OBJECT IDENTIFIER ::= { com1pm10 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.1 com1pm10Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm10BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.2 com1pm10Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm10BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.3 com1pm10ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm10BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.4 com1pm10Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm10BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.5 com1pm10PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.5.1 com1pm10PtEntry OBJECT-TYPE SYNTAX Com1pm10PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10PtIndex } ::= { com1pm10PtTable 1 } Com1pm10PtEntry ::= SEQUENCE { com1pm10PtIndex Integer32, com1pm10PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.5.1.1 com1pm10PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm10PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.5.1.2 com1pm10PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm10PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.6 com1pm10CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.6.1 com1pm10CtEntry OBJECT-TYPE SYNTAX Com1pm10CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10CtIndex } ::= { com1pm10CtTable 1 } Com1pm10CtEntry ::= SEQUENCE { com1pm10CtIndex Integer32, com1pm10CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.6.1.1 com1pm10CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm10CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.6.1.2 com1pm10CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm10CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.9 com1pm10DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm10BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.10 com1pm10DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm10BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.11 com1pm10AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm10BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.12 com1pm10AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm10BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.13 com1pm10PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm10BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.14 com1pm10RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm10BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.15 com1pm10ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm10BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.1.16 com1pm10StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm10BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2 com1pm10ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1 com1pm10ChEntry OBJECT-TYPE SYNTAX Com1pm10ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10ChSubmeterIndex } ::= { com1pm10ChTable 1 } Com1pm10ChEntry ::= SEQUENCE { com1pm10ChSubmeterIndex Integer32, com1pm10ChName OCTET STRING, com1pm10ChVoltage Opaque, com1pm10ChCurrent Opaque, com1pm10ChKW Opaque, com1pm10ChKvar Opaque, com1pm10ChKVA Opaque, com1pm10ChPF Opaque, com1pm10ChKWh Opaque, com1pm10ChKvarh Opaque, com1pm10ChKVAh Opaque, com1pm10ChActualDemand Opaque, com1pm10ChForecastDemand Opaque, com1pm10ChMaxDemandH Opaque, com1pm10ChMaxDemandD Opaque, com1pm10ChMaxDemandM Opaque, com1pm10ChElectricityD Opaque, com1pm10ChElectricityM Opaque, com1pm10ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.0 com1pm10ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm10ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.1 com1pm10ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm10ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.2 com1pm10ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm10ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.3 com1pm10ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm10ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.4 com1pm10ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm10ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.5 com1pm10ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm10ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.6 com1pm10ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm10ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.7 com1pm10ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm10ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.8 com1pm10ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm10ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.9 com1pm10ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm10ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.10 com1pm10ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm10ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.11 com1pm10ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm10ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.12 com1pm10ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm10ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.13 com1pm10ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm10ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.14 com1pm10ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm10ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.15 com1pm10ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm10ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.16 com1pm10ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm10ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.17 com1pm10ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm10ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.2.1.18 com1pm10ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm10ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3 com1pm10IOinfo OBJECT IDENTIFIER ::= { com1pm10 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.1 com1pm10DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.1.1 com1pm10DIEntry OBJECT-TYPE SYNTAX Com1pm10DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10DIIndex } ::= { com1pm10DITable 1 } Com1pm10DIEntry ::= SEQUENCE { com1pm10DIIndex Integer32, com1pm10DIName OCTET STRING, com1pm10DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.1.1.1 com1pm10DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm10DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.1.1.2 com1pm10DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm10DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.1.1.3 com1pm10DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm10DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.2 com1pm10DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.2.1 com1pm10DOEntry OBJECT-TYPE SYNTAX Com1pm10DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10DOIndex } ::= { com1pm10DOTable 1 } Com1pm10DOEntry ::= SEQUENCE { com1pm10DOIndex Integer32, com1pm10DOName OCTET STRING, com1pm10DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.2.1.1 com1pm10DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm10DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.2.1.2 com1pm10DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm10DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.2.1.3 com1pm10DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm10DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.3 com1pm10AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.3.1 com1pm10AIEntry OBJECT-TYPE SYNTAX Com1pm10AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10AIIndex } ::= { com1pm10AITable 1 } Com1pm10AIEntry ::= SEQUENCE { com1pm10AIIndex Integer32, com1pm10AIName OCTET STRING, com1pm10AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.3.1.1 com1pm10AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm10AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.3.1.2 com1pm10AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm10AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.3.1.3 com1pm10AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm10AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.4 com1pm10AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.4.1 com1pm10AOEntry OBJECT-TYPE SYNTAX Com1pm10AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10AOIndex } ::= { com1pm10AOTable 1 } Com1pm10AOEntry ::= SEQUENCE { com1pm10AOIndex Integer32, com1pm10AOName OCTET STRING, com1pm10AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.4.1.1 com1pm10AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm10AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.4.1.2 com1pm10AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm10AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.3.4.1.3 com1pm10AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm10AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.4 com1pm10HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm10HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm10 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.4.1 com1pm10HarmonicEntry OBJECT-TYPE SYNTAX Com1pm10HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm10HarmonicSubmeterIndex } ::= { com1pm10HarmonicTable 1 } Com1pm10HarmonicEntry ::= SEQUENCE { com1pm10HarmonicSubmeterIndex Integer32, com1pm10HarmonicSelector Integer32, com1pm10HarmonicVTHD Opaque, com1pm10HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.4.1.1 com1pm10HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm10HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.4.1.2 com1pm10HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm10HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.4.1.3 com1pm10HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm10HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.10.4.1.4 com1pm10HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm10HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11 com1pm11 OBJECT IDENTIFIER ::= { com1pm 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1 com1pm11BasicInfo OBJECT IDENTIFIER ::= { com1pm11 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.1 com1pm11Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm11BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.2 com1pm11Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm11BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.3 com1pm11ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm11BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.4 com1pm11Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm11BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.5 com1pm11PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.5.1 com1pm11PtEntry OBJECT-TYPE SYNTAX Com1pm11PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11PtIndex } ::= { com1pm11PtTable 1 } Com1pm11PtEntry ::= SEQUENCE { com1pm11PtIndex Integer32, com1pm11PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.5.1.1 com1pm11PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm11PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.5.1.2 com1pm11PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm11PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.6 com1pm11CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.6.1 com1pm11CtEntry OBJECT-TYPE SYNTAX Com1pm11CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11CtIndex } ::= { com1pm11CtTable 1 } Com1pm11CtEntry ::= SEQUENCE { com1pm11CtIndex Integer32, com1pm11CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.6.1.1 com1pm11CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm11CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.6.1.2 com1pm11CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm11CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.9 com1pm11DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm11BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.10 com1pm11DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm11BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.11 com1pm11AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm11BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.12 com1pm11AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm11BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.13 com1pm11PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm11BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.14 com1pm11RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm11BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.15 com1pm11ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm11BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.1.16 com1pm11StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm11BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2 com1pm11ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1 com1pm11ChEntry OBJECT-TYPE SYNTAX Com1pm11ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11ChSubmeterIndex } ::= { com1pm11ChTable 1 } Com1pm11ChEntry ::= SEQUENCE { com1pm11ChSubmeterIndex Integer32, com1pm11ChName OCTET STRING, com1pm11ChVoltage Opaque, com1pm11ChCurrent Opaque, com1pm11ChKW Opaque, com1pm11ChKvar Opaque, com1pm11ChKVA Opaque, com1pm11ChPF Opaque, com1pm11ChKWh Opaque, com1pm11ChKvarh Opaque, com1pm11ChKVAh Opaque, com1pm11ChActualDemand Opaque, com1pm11ChForecastDemand Opaque, com1pm11ChMaxDemandH Opaque, com1pm11ChMaxDemandD Opaque, com1pm11ChMaxDemandM Opaque, com1pm11ChElectricityD Opaque, com1pm11ChElectricityM Opaque, com1pm11ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.0 com1pm11ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm11ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.1 com1pm11ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm11ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.2 com1pm11ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm11ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.3 com1pm11ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm11ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.4 com1pm11ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm11ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.5 com1pm11ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm11ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.6 com1pm11ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm11ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.7 com1pm11ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm11ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.8 com1pm11ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm11ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.9 com1pm11ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm11ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.10 com1pm11ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm11ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.11 com1pm11ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm11ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.12 com1pm11ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm11ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.13 com1pm11ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm11ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.14 com1pm11ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm11ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.15 com1pm11ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm11ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.16 com1pm11ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm11ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.17 com1pm11ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm11ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.2.1.18 com1pm11ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm11ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3 com1pm11IOinfo OBJECT IDENTIFIER ::= { com1pm11 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.1 com1pm11DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.1.1 com1pm11DIEntry OBJECT-TYPE SYNTAX Com1pm11DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11DIIndex } ::= { com1pm11DITable 1 } Com1pm11DIEntry ::= SEQUENCE { com1pm11DIIndex Integer32, com1pm11DIName OCTET STRING, com1pm11DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.1.1.1 com1pm11DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm11DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.1.1.2 com1pm11DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm11DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.1.1.3 com1pm11DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm11DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.2 com1pm11DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.2.1 com1pm11DOEntry OBJECT-TYPE SYNTAX Com1pm11DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11DOIndex } ::= { com1pm11DOTable 1 } Com1pm11DOEntry ::= SEQUENCE { com1pm11DOIndex Integer32, com1pm11DOName OCTET STRING, com1pm11DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.2.1.1 com1pm11DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm11DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.2.1.2 com1pm11DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm11DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.2.1.3 com1pm11DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm11DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.3 com1pm11AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.3.1 com1pm11AIEntry OBJECT-TYPE SYNTAX Com1pm11AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11AIIndex } ::= { com1pm11AITable 1 } Com1pm11AIEntry ::= SEQUENCE { com1pm11AIIndex Integer32, com1pm11AIName OCTET STRING, com1pm11AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.3.1.1 com1pm11AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm11AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.3.1.2 com1pm11AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm11AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.3.1.3 com1pm11AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm11AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.4 com1pm11AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.4.1 com1pm11AOEntry OBJECT-TYPE SYNTAX Com1pm11AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11AOIndex } ::= { com1pm11AOTable 1 } Com1pm11AOEntry ::= SEQUENCE { com1pm11AOIndex Integer32, com1pm11AOName OCTET STRING, com1pm11AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.4.1.1 com1pm11AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm11AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.4.1.2 com1pm11AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm11AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.3.4.1.3 com1pm11AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm11AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.4 com1pm11HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm11HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm11 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.4.1 com1pm11HarmonicEntry OBJECT-TYPE SYNTAX Com1pm11HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm11HarmonicSubmeterIndex } ::= { com1pm11HarmonicTable 1 } Com1pm11HarmonicEntry ::= SEQUENCE { com1pm11HarmonicSubmeterIndex Integer32, com1pm11HarmonicSelector Integer32, com1pm11HarmonicVTHD Opaque, com1pm11HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.4.1.1 com1pm11HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm11HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.4.1.2 com1pm11HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm11HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.4.1.3 com1pm11HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm11HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.11.4.1.4 com1pm11HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm11HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12 com1pm12 OBJECT IDENTIFIER ::= { com1pm 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1 com1pm12BasicInfo OBJECT IDENTIFIER ::= { com1pm12 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.1 com1pm12Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm12BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.2 com1pm12Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm12BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.3 com1pm12ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm12BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.4 com1pm12Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm12BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.5 com1pm12PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.5.1 com1pm12PtEntry OBJECT-TYPE SYNTAX Com1pm12PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12PtIndex } ::= { com1pm12PtTable 1 } Com1pm12PtEntry ::= SEQUENCE { com1pm12PtIndex Integer32, com1pm12PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.5.1.1 com1pm12PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm12PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.5.1.2 com1pm12PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm12PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.6 com1pm12CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.6.1 com1pm12CtEntry OBJECT-TYPE SYNTAX Com1pm12CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12CtIndex } ::= { com1pm12CtTable 1 } Com1pm12CtEntry ::= SEQUENCE { com1pm12CtIndex Integer32, com1pm12CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.6.1.1 com1pm12CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm12CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.6.1.2 com1pm12CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm12CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.9 com1pm12DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm12BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.10 com1pm12DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm12BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.11 com1pm12AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm12BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.12 com1pm12AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm12BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.13 com1pm12PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm12BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.14 com1pm12RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm12BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.15 com1pm12ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm12BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.1.16 com1pm12StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm12BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2 com1pm12ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1 com1pm12ChEntry OBJECT-TYPE SYNTAX Com1pm12ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12ChSubmeterIndex } ::= { com1pm12ChTable 1 } Com1pm12ChEntry ::= SEQUENCE { com1pm12ChSubmeterIndex Integer32, com1pm12ChName OCTET STRING, com1pm12ChVoltage Opaque, com1pm12ChCurrent Opaque, com1pm12ChKW Opaque, com1pm12ChKvar Opaque, com1pm12ChKVA Opaque, com1pm12ChPF Opaque, com1pm12ChKWh Opaque, com1pm12ChKvarh Opaque, com1pm12ChKVAh Opaque, com1pm12ChActualDemand Opaque, com1pm12ChForecastDemand Opaque, com1pm12ChMaxDemandH Opaque, com1pm12ChMaxDemandD Opaque, com1pm12ChMaxDemandM Opaque, com1pm12ChElectricityD Opaque, com1pm12ChElectricityM Opaque, com1pm12ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.0 com1pm12ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm12ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.1 com1pm12ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm12ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.2 com1pm12ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm12ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.3 com1pm12ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm12ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.4 com1pm12ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm12ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.5 com1pm12ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm12ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.6 com1pm12ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm12ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.7 com1pm12ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm12ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.8 com1pm12ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm12ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.9 com1pm12ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm12ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.10 com1pm12ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm12ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.11 com1pm12ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm12ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.12 com1pm12ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm12ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.13 com1pm12ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm12ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.14 com1pm12ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm12ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.15 com1pm12ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm12ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.16 com1pm12ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm12ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.17 com1pm12ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm12ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.2.1.18 com1pm12ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm12ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3 com1pm12IOinfo OBJECT IDENTIFIER ::= { com1pm12 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.1 com1pm12DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.1.1 com1pm12DIEntry OBJECT-TYPE SYNTAX Com1pm12DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12DIIndex } ::= { com1pm12DITable 1 } Com1pm12DIEntry ::= SEQUENCE { com1pm12DIIndex Integer32, com1pm12DIName OCTET STRING, com1pm12DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.1.1.1 com1pm12DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm12DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.1.1.2 com1pm12DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm12DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.1.1.3 com1pm12DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm12DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.2 com1pm12DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.2.1 com1pm12DOEntry OBJECT-TYPE SYNTAX Com1pm12DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12DOIndex } ::= { com1pm12DOTable 1 } Com1pm12DOEntry ::= SEQUENCE { com1pm12DOIndex Integer32, com1pm12DOName OCTET STRING, com1pm12DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.2.1.1 com1pm12DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm12DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.2.1.2 com1pm12DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm12DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.2.1.3 com1pm12DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm12DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.3 com1pm12AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.3.1 com1pm12AIEntry OBJECT-TYPE SYNTAX Com1pm12AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12AIIndex } ::= { com1pm12AITable 1 } Com1pm12AIEntry ::= SEQUENCE { com1pm12AIIndex Integer32, com1pm12AIName OCTET STRING, com1pm12AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.3.1.1 com1pm12AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm12AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.3.1.2 com1pm12AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm12AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.3.1.3 com1pm12AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm12AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.4 com1pm12AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.4.1 com1pm12AOEntry OBJECT-TYPE SYNTAX Com1pm12AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12AOIndex } ::= { com1pm12AOTable 1 } Com1pm12AOEntry ::= SEQUENCE { com1pm12AOIndex Integer32, com1pm12AOName OCTET STRING, com1pm12AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.4.1.1 com1pm12AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm12AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.4.1.2 com1pm12AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm12AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.3.4.1.3 com1pm12AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm12AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.4 com1pm12HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm12HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm12 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.4.1 com1pm12HarmonicEntry OBJECT-TYPE SYNTAX Com1pm12HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm12HarmonicSubmeterIndex } ::= { com1pm12HarmonicTable 1 } Com1pm12HarmonicEntry ::= SEQUENCE { com1pm12HarmonicSubmeterIndex Integer32, com1pm12HarmonicSelector Integer32, com1pm12HarmonicVTHD Opaque, com1pm12HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.4.1.1 com1pm12HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm12HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.4.1.2 com1pm12HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm12HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.4.1.3 com1pm12HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm12HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.12.4.1.4 com1pm12HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm12HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13 com1pm13 OBJECT IDENTIFIER ::= { com1pm 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1 com1pm13BasicInfo OBJECT IDENTIFIER ::= { com1pm13 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.1 com1pm13Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm13BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.2 com1pm13Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm13BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.3 com1pm13ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm13BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.4 com1pm13Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm13BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.5 com1pm13PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.5.1 com1pm13PtEntry OBJECT-TYPE SYNTAX Com1pm13PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13PtIndex } ::= { com1pm13PtTable 1 } Com1pm13PtEntry ::= SEQUENCE { com1pm13PtIndex Integer32, com1pm13PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.5.1.1 com1pm13PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm13PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.5.1.2 com1pm13PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm13PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.6 com1pm13CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.6.1 com1pm13CtEntry OBJECT-TYPE SYNTAX Com1pm13CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13CtIndex } ::= { com1pm13CtTable 1 } Com1pm13CtEntry ::= SEQUENCE { com1pm13CtIndex Integer32, com1pm13CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.6.1.1 com1pm13CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm13CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.6.1.2 com1pm13CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm13CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.9 com1pm13DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm13BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.10 com1pm13DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm13BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.11 com1pm13AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm13BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.12 com1pm13AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm13BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.13 com1pm13PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm13BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.14 com1pm13RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm13BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.15 com1pm13ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm13BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.1.16 com1pm13StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm13BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2 com1pm13ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1 com1pm13ChEntry OBJECT-TYPE SYNTAX Com1pm13ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13ChSubmeterIndex } ::= { com1pm13ChTable 1 } Com1pm13ChEntry ::= SEQUENCE { com1pm13ChSubmeterIndex Integer32, com1pm13ChName OCTET STRING, com1pm13ChVoltage Opaque, com1pm13ChCurrent Opaque, com1pm13ChKW Opaque, com1pm13ChKvar Opaque, com1pm13ChKVA Opaque, com1pm13ChPF Opaque, com1pm13ChKWh Opaque, com1pm13ChKvarh Opaque, com1pm13ChKVAh Opaque, com1pm13ChActualDemand Opaque, com1pm13ChForecastDemand Opaque, com1pm13ChMaxDemandH Opaque, com1pm13ChMaxDemandD Opaque, com1pm13ChMaxDemandM Opaque, com1pm13ChElectricityD Opaque, com1pm13ChElectricityM Opaque, com1pm13ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.0 com1pm13ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm13ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.1 com1pm13ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm13ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.2 com1pm13ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm13ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.3 com1pm13ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm13ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.4 com1pm13ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm13ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.5 com1pm13ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm13ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.6 com1pm13ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm13ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.7 com1pm13ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm13ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.8 com1pm13ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm13ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.9 com1pm13ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm13ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.10 com1pm13ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm13ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.11 com1pm13ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm13ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.12 com1pm13ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm13ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.13 com1pm13ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm13ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.14 com1pm13ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm13ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.15 com1pm13ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm13ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.16 com1pm13ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm13ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.17 com1pm13ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm13ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.2.1.18 com1pm13ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm13ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3 com1pm13IOinfo OBJECT IDENTIFIER ::= { com1pm13 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.1 com1pm13DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.1.1 com1pm13DIEntry OBJECT-TYPE SYNTAX Com1pm13DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13DIIndex } ::= { com1pm13DITable 1 } Com1pm13DIEntry ::= SEQUENCE { com1pm13DIIndex Integer32, com1pm13DIName OCTET STRING, com1pm13DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.1.1.1 com1pm13DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm13DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.1.1.2 com1pm13DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm13DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.1.1.3 com1pm13DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm13DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.2 com1pm13DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.2.1 com1pm13DOEntry OBJECT-TYPE SYNTAX Com1pm13DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13DOIndex } ::= { com1pm13DOTable 1 } Com1pm13DOEntry ::= SEQUENCE { com1pm13DOIndex Integer32, com1pm13DOName OCTET STRING, com1pm13DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.2.1.1 com1pm13DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm13DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.2.1.2 com1pm13DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm13DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.2.1.3 com1pm13DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm13DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.3 com1pm13AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.3.1 com1pm13AIEntry OBJECT-TYPE SYNTAX Com1pm13AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13AIIndex } ::= { com1pm13AITable 1 } Com1pm13AIEntry ::= SEQUENCE { com1pm13AIIndex Integer32, com1pm13AIName OCTET STRING, com1pm13AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.3.1.1 com1pm13AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm13AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.3.1.2 com1pm13AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm13AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.3.1.3 com1pm13AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm13AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.4 com1pm13AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.4.1 com1pm13AOEntry OBJECT-TYPE SYNTAX Com1pm13AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13AOIndex } ::= { com1pm13AOTable 1 } Com1pm13AOEntry ::= SEQUENCE { com1pm13AOIndex Integer32, com1pm13AOName OCTET STRING, com1pm13AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.4.1.1 com1pm13AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm13AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.4.1.2 com1pm13AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm13AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.3.4.1.3 com1pm13AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm13AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.4 com1pm13HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm13HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm13 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.4.1 com1pm13HarmonicEntry OBJECT-TYPE SYNTAX Com1pm13HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm13HarmonicSubmeterIndex } ::= { com1pm13HarmonicTable 1 } Com1pm13HarmonicEntry ::= SEQUENCE { com1pm13HarmonicSubmeterIndex Integer32, com1pm13HarmonicSelector Integer32, com1pm13HarmonicVTHD Opaque, com1pm13HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.4.1.1 com1pm13HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm13HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.4.1.2 com1pm13HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm13HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.4.1.3 com1pm13HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm13HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.13.4.1.4 com1pm13HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm13HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14 com1pm14 OBJECT IDENTIFIER ::= { com1pm 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1 com1pm14BasicInfo OBJECT IDENTIFIER ::= { com1pm14 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.1 com1pm14Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm14BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.2 com1pm14Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm14BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.3 com1pm14ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm14BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.4 com1pm14Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm14BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.5 com1pm14PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.5.1 com1pm14PtEntry OBJECT-TYPE SYNTAX Com1pm14PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14PtIndex } ::= { com1pm14PtTable 1 } Com1pm14PtEntry ::= SEQUENCE { com1pm14PtIndex Integer32, com1pm14PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.5.1.1 com1pm14PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm14PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.5.1.2 com1pm14PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm14PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.6 com1pm14CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.6.1 com1pm14CtEntry OBJECT-TYPE SYNTAX Com1pm14CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14CtIndex } ::= { com1pm14CtTable 1 } Com1pm14CtEntry ::= SEQUENCE { com1pm14CtIndex Integer32, com1pm14CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.6.1.1 com1pm14CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm14CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.6.1.2 com1pm14CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm14CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.9 com1pm14DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm14BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.10 com1pm14DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm14BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.11 com1pm14AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm14BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.12 com1pm14AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm14BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.13 com1pm14PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm14BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.14 com1pm14RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm14BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.15 com1pm14ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm14BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.1.16 com1pm14StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm14BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2 com1pm14ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1 com1pm14ChEntry OBJECT-TYPE SYNTAX Com1pm14ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14ChSubmeterIndex } ::= { com1pm14ChTable 1 } Com1pm14ChEntry ::= SEQUENCE { com1pm14ChSubmeterIndex Integer32, com1pm14ChName OCTET STRING, com1pm14ChVoltage Opaque, com1pm14ChCurrent Opaque, com1pm14ChKW Opaque, com1pm14ChKvar Opaque, com1pm14ChKVA Opaque, com1pm14ChPF Opaque, com1pm14ChKWh Opaque, com1pm14ChKvarh Opaque, com1pm14ChKVAh Opaque, com1pm14ChActualDemand Opaque, com1pm14ChForecastDemand Opaque, com1pm14ChMaxDemandH Opaque, com1pm14ChMaxDemandD Opaque, com1pm14ChMaxDemandM Opaque, com1pm14ChElectricityD Opaque, com1pm14ChElectricityM Opaque, com1pm14ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.0 com1pm14ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm14ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.1 com1pm14ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm14ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.2 com1pm14ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm14ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.3 com1pm14ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm14ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.4 com1pm14ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm14ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.5 com1pm14ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm14ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.6 com1pm14ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm14ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.7 com1pm14ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm14ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.8 com1pm14ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm14ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.9 com1pm14ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm14ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.10 com1pm14ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm14ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.11 com1pm14ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm14ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.12 com1pm14ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm14ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.13 com1pm14ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm14ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.14 com1pm14ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm14ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.15 com1pm14ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm14ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.16 com1pm14ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm14ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.17 com1pm14ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm14ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.2.1.18 com1pm14ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm14ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3 com1pm14IOinfo OBJECT IDENTIFIER ::= { com1pm14 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.1 com1pm14DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.1.1 com1pm14DIEntry OBJECT-TYPE SYNTAX Com1pm14DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14DIIndex } ::= { com1pm14DITable 1 } Com1pm14DIEntry ::= SEQUENCE { com1pm14DIIndex Integer32, com1pm14DIName OCTET STRING, com1pm14DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.1.1.1 com1pm14DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm14DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.1.1.2 com1pm14DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm14DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.1.1.3 com1pm14DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm14DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.2 com1pm14DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.2.1 com1pm14DOEntry OBJECT-TYPE SYNTAX Com1pm14DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14DOIndex } ::= { com1pm14DOTable 1 } Com1pm14DOEntry ::= SEQUENCE { com1pm14DOIndex Integer32, com1pm14DOName OCTET STRING, com1pm14DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.2.1.1 com1pm14DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm14DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.2.1.2 com1pm14DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm14DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.2.1.3 com1pm14DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm14DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.3 com1pm14AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.3.1 com1pm14AIEntry OBJECT-TYPE SYNTAX Com1pm14AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14AIIndex } ::= { com1pm14AITable 1 } Com1pm14AIEntry ::= SEQUENCE { com1pm14AIIndex Integer32, com1pm14AIName OCTET STRING, com1pm14AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.3.1.1 com1pm14AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm14AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.3.1.2 com1pm14AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm14AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.3.1.3 com1pm14AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm14AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.4 com1pm14AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.4.1 com1pm14AOEntry OBJECT-TYPE SYNTAX Com1pm14AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14AOIndex } ::= { com1pm14AOTable 1 } Com1pm14AOEntry ::= SEQUENCE { com1pm14AOIndex Integer32, com1pm14AOName OCTET STRING, com1pm14AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.4.1.1 com1pm14AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm14AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.4.1.2 com1pm14AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm14AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.3.4.1.3 com1pm14AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm14AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.4 com1pm14HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm14HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm14 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.4.1 com1pm14HarmonicEntry OBJECT-TYPE SYNTAX Com1pm14HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm14HarmonicSubmeterIndex } ::= { com1pm14HarmonicTable 1 } Com1pm14HarmonicEntry ::= SEQUENCE { com1pm14HarmonicSubmeterIndex Integer32, com1pm14HarmonicSelector Integer32, com1pm14HarmonicVTHD Opaque, com1pm14HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.4.1.1 com1pm14HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm14HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.4.1.2 com1pm14HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm14HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.4.1.3 com1pm14HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm14HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.14.4.1.4 com1pm14HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm14HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15 com1pm15 OBJECT IDENTIFIER ::= { com1pm 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1 com1pm15BasicInfo OBJECT IDENTIFIER ::= { com1pm15 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.1 com1pm15Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm15BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.2 com1pm15Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm15BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.3 com1pm15ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm15BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.4 com1pm15Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm15BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.5 com1pm15PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.5.1 com1pm15PtEntry OBJECT-TYPE SYNTAX Com1pm15PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15PtIndex } ::= { com1pm15PtTable 1 } Com1pm15PtEntry ::= SEQUENCE { com1pm15PtIndex Integer32, com1pm15PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.5.1.1 com1pm15PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm15PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.5.1.2 com1pm15PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm15PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.6 com1pm15CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.6.1 com1pm15CtEntry OBJECT-TYPE SYNTAX Com1pm15CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15CtIndex } ::= { com1pm15CtTable 1 } Com1pm15CtEntry ::= SEQUENCE { com1pm15CtIndex Integer32, com1pm15CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.6.1.1 com1pm15CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm15CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.6.1.2 com1pm15CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm15CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.9 com1pm15DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm15BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.10 com1pm15DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm15BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.11 com1pm15AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm15BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.12 com1pm15AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm15BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.13 com1pm15PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm15BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.14 com1pm15RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm15BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.15 com1pm15ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm15BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.1.16 com1pm15StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm15BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2 com1pm15ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1 com1pm15ChEntry OBJECT-TYPE SYNTAX Com1pm15ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15ChSubmeterIndex } ::= { com1pm15ChTable 1 } Com1pm15ChEntry ::= SEQUENCE { com1pm15ChSubmeterIndex Integer32, com1pm15ChName OCTET STRING, com1pm15ChVoltage Opaque, com1pm15ChCurrent Opaque, com1pm15ChKW Opaque, com1pm15ChKvar Opaque, com1pm15ChKVA Opaque, com1pm15ChPF Opaque, com1pm15ChKWh Opaque, com1pm15ChKvarh Opaque, com1pm15ChKVAh Opaque, com1pm15ChActualDemand Opaque, com1pm15ChForecastDemand Opaque, com1pm15ChMaxDemandH Opaque, com1pm15ChMaxDemandD Opaque, com1pm15ChMaxDemandM Opaque, com1pm15ChElectricityD Opaque, com1pm15ChElectricityM Opaque, com1pm15ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.0 com1pm15ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm15ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.1 com1pm15ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm15ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.2 com1pm15ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm15ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.3 com1pm15ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm15ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.4 com1pm15ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm15ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.5 com1pm15ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm15ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.6 com1pm15ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm15ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.7 com1pm15ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm15ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.8 com1pm15ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm15ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.9 com1pm15ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm15ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.10 com1pm15ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm15ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.11 com1pm15ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm15ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.12 com1pm15ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm15ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.13 com1pm15ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm15ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.14 com1pm15ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm15ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.15 com1pm15ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm15ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.16 com1pm15ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm15ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.17 com1pm15ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm15ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.2.1.18 com1pm15ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm15ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3 com1pm15IOinfo OBJECT IDENTIFIER ::= { com1pm15 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.1 com1pm15DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.1.1 com1pm15DIEntry OBJECT-TYPE SYNTAX Com1pm15DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15DIIndex } ::= { com1pm15DITable 1 } Com1pm15DIEntry ::= SEQUENCE { com1pm15DIIndex Integer32, com1pm15DIName OCTET STRING, com1pm15DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.1.1.1 com1pm15DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm15DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.1.1.2 com1pm15DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm15DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.1.1.3 com1pm15DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm15DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.2 com1pm15DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.2.1 com1pm15DOEntry OBJECT-TYPE SYNTAX Com1pm15DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15DOIndex } ::= { com1pm15DOTable 1 } Com1pm15DOEntry ::= SEQUENCE { com1pm15DOIndex Integer32, com1pm15DOName OCTET STRING, com1pm15DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.2.1.1 com1pm15DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm15DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.2.1.2 com1pm15DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm15DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.2.1.3 com1pm15DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm15DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.3 com1pm15AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.3.1 com1pm15AIEntry OBJECT-TYPE SYNTAX Com1pm15AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15AIIndex } ::= { com1pm15AITable 1 } Com1pm15AIEntry ::= SEQUENCE { com1pm15AIIndex Integer32, com1pm15AIName OCTET STRING, com1pm15AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.3.1.1 com1pm15AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm15AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.3.1.2 com1pm15AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm15AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.3.1.3 com1pm15AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm15AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.4 com1pm15AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.4.1 com1pm15AOEntry OBJECT-TYPE SYNTAX Com1pm15AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15AOIndex } ::= { com1pm15AOTable 1 } Com1pm15AOEntry ::= SEQUENCE { com1pm15AOIndex Integer32, com1pm15AOName OCTET STRING, com1pm15AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.4.1.1 com1pm15AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm15AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.4.1.2 com1pm15AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm15AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.3.4.1.3 com1pm15AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm15AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.4 com1pm15HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm15HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm15 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.4.1 com1pm15HarmonicEntry OBJECT-TYPE SYNTAX Com1pm15HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm15HarmonicSubmeterIndex } ::= { com1pm15HarmonicTable 1 } Com1pm15HarmonicEntry ::= SEQUENCE { com1pm15HarmonicSubmeterIndex Integer32, com1pm15HarmonicSelector Integer32, com1pm15HarmonicVTHD Opaque, com1pm15HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.4.1.1 com1pm15HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm15HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.4.1.2 com1pm15HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm15HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.4.1.3 com1pm15HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm15HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.15.4.1.4 com1pm15HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm15HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16 com1pm16 OBJECT IDENTIFIER ::= { com1pm 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1 com1pm16BasicInfo OBJECT IDENTIFIER ::= { com1pm16 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.1 com1pm16Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com1pm16BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.2 com1pm16Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com1pm16BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.3 com1pm16ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com1pm16BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.4 com1pm16Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com1pm16BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.5 com1pm16PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.5.1 com1pm16PtEntry OBJECT-TYPE SYNTAX Com1pm16PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16PtIndex } ::= { com1pm16PtTable 1 } Com1pm16PtEntry ::= SEQUENCE { com1pm16PtIndex Integer32, com1pm16PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.5.1.1 com1pm16PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com1pm16PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.5.1.2 com1pm16PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com1pm16PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.6 com1pm16CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.6.1 com1pm16CtEntry OBJECT-TYPE SYNTAX Com1pm16CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16CtIndex } ::= { com1pm16CtTable 1 } Com1pm16CtEntry ::= SEQUENCE { com1pm16CtIndex Integer32, com1pm16CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.6.1.1 com1pm16CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com1pm16CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.6.1.2 com1pm16CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com1pm16CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.9 com1pm16DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com1pm16BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.10 com1pm16DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com1pm16BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.11 com1pm16AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com1pm16BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.12 com1pm16AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com1pm16BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.13 com1pm16PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com1pm16BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.14 com1pm16RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com1pm16BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.15 com1pm16ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com1pm16BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.1.16 com1pm16StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com1pm16BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2 com1pm16ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1 com1pm16ChEntry OBJECT-TYPE SYNTAX Com1pm16ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16ChSubmeterIndex } ::= { com1pm16ChTable 1 } Com1pm16ChEntry ::= SEQUENCE { com1pm16ChSubmeterIndex Integer32, com1pm16ChName OCTET STRING, com1pm16ChVoltage Opaque, com1pm16ChCurrent Opaque, com1pm16ChKW Opaque, com1pm16ChKvar Opaque, com1pm16ChKVA Opaque, com1pm16ChPF Opaque, com1pm16ChKWh Opaque, com1pm16ChKvarh Opaque, com1pm16ChKVAh Opaque, com1pm16ChActualDemand Opaque, com1pm16ChForecastDemand Opaque, com1pm16ChMaxDemandH Opaque, com1pm16ChMaxDemandD Opaque, com1pm16ChMaxDemandM Opaque, com1pm16ChElectricityD Opaque, com1pm16ChElectricityM Opaque, com1pm16ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.0 com1pm16ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm16ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.1 com1pm16ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com1pm16ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.2 com1pm16ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com1pm16ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.3 com1pm16ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com1pm16ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.4 com1pm16ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com1pm16ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.5 com1pm16ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com1pm16ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.6 com1pm16ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com1pm16ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.7 com1pm16ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com1pm16ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.8 com1pm16ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com1pm16ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.9 com1pm16ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com1pm16ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.10 com1pm16ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com1pm16ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.11 com1pm16ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com1pm16ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.12 com1pm16ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com1pm16ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.13 com1pm16ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com1pm16ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.14 com1pm16ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com1pm16ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.15 com1pm16ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com1pm16ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.16 com1pm16ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com1pm16ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.17 com1pm16ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com1pm16ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.2.1.18 com1pm16ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com1pm16ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3 com1pm16IOinfo OBJECT IDENTIFIER ::= { com1pm16 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.1 com1pm16DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.1.1 com1pm16DIEntry OBJECT-TYPE SYNTAX Com1pm16DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16DIIndex } ::= { com1pm16DITable 1 } Com1pm16DIEntry ::= SEQUENCE { com1pm16DIIndex Integer32, com1pm16DIName OCTET STRING, com1pm16DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.1.1.1 com1pm16DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com1pm16DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.1.1.2 com1pm16DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com1pm16DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.1.1.3 com1pm16DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com1pm16DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.2 com1pm16DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.2.1 com1pm16DOEntry OBJECT-TYPE SYNTAX Com1pm16DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16DOIndex } ::= { com1pm16DOTable 1 } Com1pm16DOEntry ::= SEQUENCE { com1pm16DOIndex Integer32, com1pm16DOName OCTET STRING, com1pm16DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.2.1.1 com1pm16DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com1pm16DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.2.1.2 com1pm16DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com1pm16DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.2.1.3 com1pm16DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com1pm16DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.3 com1pm16AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.3.1 com1pm16AIEntry OBJECT-TYPE SYNTAX Com1pm16AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16AIIndex } ::= { com1pm16AITable 1 } Com1pm16AIEntry ::= SEQUENCE { com1pm16AIIndex Integer32, com1pm16AIName OCTET STRING, com1pm16AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.3.1.1 com1pm16AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com1pm16AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.3.1.2 com1pm16AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com1pm16AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.3.1.3 com1pm16AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com1pm16AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.4 com1pm16AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.4.1 com1pm16AOEntry OBJECT-TYPE SYNTAX Com1pm16AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16AOIndex } ::= { com1pm16AOTable 1 } Com1pm16AOEntry ::= SEQUENCE { com1pm16AOIndex Integer32, com1pm16AOName OCTET STRING, com1pm16AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.4.1.1 com1pm16AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com1pm16AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.4.1.2 com1pm16AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com1pm16AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.3.4.1.3 com1pm16AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com1pm16AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.4 com1pm16HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1pm16HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1pm16 4 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.4.1 com1pm16HarmonicEntry OBJECT-TYPE SYNTAX Com1pm16HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1pm16HarmonicSubmeterIndex } ::= { com1pm16HarmonicTable 1 } Com1pm16HarmonicEntry ::= SEQUENCE { com1pm16HarmonicSubmeterIndex Integer32, com1pm16HarmonicSelector Integer32, com1pm16HarmonicVTHD Opaque, com1pm16HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.4.1.1 com1pm16HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com1pm16HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.4.1.2 com1pm16HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com1pm16HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.4.1.3 com1pm16HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com1pm16HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.1.16.4.1.4 com1pm16HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com1pm16HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2 com2pm OBJECT IDENTIFIER ::= { powerMeterInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1 com2pm1 OBJECT IDENTIFIER ::= { com2pm 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1 com2pm1BasicInfo OBJECT IDENTIFIER ::= { com2pm1 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.1 com2pm1Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm1BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.2 com2pm1Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm1BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.3 com2pm1ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm1BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.4 com2pm1Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm1BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.5 com2pm1PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.5.1 com2pm1PtEntry OBJECT-TYPE SYNTAX Com2pm1PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1PtIndex } ::= { com2pm1PtTable 1 } Com2pm1PtEntry ::= SEQUENCE { com2pm1PtIndex Integer32, com2pm1PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.5.1.1 com2pm1PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm1PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.5.1.2 com2pm1PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm1PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.6 com2pm1CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.6.1 com2pm1CtEntry OBJECT-TYPE SYNTAX Com2pm1CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1CtIndex } ::= { com2pm1CtTable 1 } Com2pm1CtEntry ::= SEQUENCE { com2pm1CtIndex Integer32, com2pm1CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.6.1.1 com2pm1CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm1CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.6.1.2 com2pm1CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm1CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.9 com2pm1DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm1BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.10 com2pm1DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm1BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.11 com2pm1AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm1BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.12 com2pm1AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm1BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.13 com2pm1PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm1BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.14 com2pm1RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm1BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.15 com2pm1ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm1BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.1.16 com2pm1StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm1BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2 com2pm1ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1 com2pm1ChEntry OBJECT-TYPE SYNTAX Com2pm1ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1ChSubmeterIndex } ::= { com2pm1ChTable 1 } Com2pm1ChEntry ::= SEQUENCE { com2pm1ChSubmeterIndex Integer32, com2pm1ChName OCTET STRING, com2pm1ChVoltage Opaque, com2pm1ChCurrent Opaque, com2pm1ChKW Opaque, com2pm1ChKvar Opaque, com2pm1ChKVA Opaque, com2pm1ChPF Opaque, com2pm1ChKWh Opaque, com2pm1ChKvarh Opaque, com2pm1ChKVAh Opaque, com2pm1ChActualDemand Opaque, com2pm1ChForecastDemand Opaque, com2pm1ChMaxDemandH Opaque, com2pm1ChMaxDemandD Opaque, com2pm1ChMaxDemandM Opaque, com2pm1ChElectricityD Opaque, com2pm1ChElectricityM Opaque, com2pm1ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.0 com2pm1ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm1ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.1 com2pm1ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm1ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.2 com2pm1ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm1ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.3 com2pm1ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm1ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.4 com2pm1ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm1ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.5 com2pm1ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm1ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.6 com2pm1ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm1ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.7 com2pm1ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm1ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.8 com2pm1ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm1ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.9 com2pm1ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm1ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.10 com2pm1ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm1ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.11 com2pm1ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm1ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.12 com2pm1ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm1ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.13 com2pm1ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm1ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.14 com2pm1ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm1ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.15 com2pm1ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm1ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.16 com2pm1ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm1ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.17 com2pm1ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm1ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.2.1.18 com2pm1ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm1ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3 com2pm1IOinfo OBJECT IDENTIFIER ::= { com2pm1 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.1 com2pm1DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.1.1 com2pm1DIEntry OBJECT-TYPE SYNTAX Com2pm1DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1DIIndex } ::= { com2pm1DITable 1 } Com2pm1DIEntry ::= SEQUENCE { com2pm1DIIndex Integer32, com2pm1DIName OCTET STRING, com2pm1DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.1.1.1 com2pm1DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm1DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.1.1.2 com2pm1DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm1DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.1.1.3 com2pm1DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm1DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.2 com2pm1DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.2.1 com2pm1DOEntry OBJECT-TYPE SYNTAX Com2pm1DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1DOIndex } ::= { com2pm1DOTable 1 } Com2pm1DOEntry ::= SEQUENCE { com2pm1DOIndex Integer32, com2pm1DOName OCTET STRING, com2pm1DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.2.1.1 com2pm1DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm1DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.2.1.2 com2pm1DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm1DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.2.1.3 com2pm1DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm1DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.3 com2pm1AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.3.1 com2pm1AIEntry OBJECT-TYPE SYNTAX Com2pm1AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1AIIndex } ::= { com2pm1AITable 1 } Com2pm1AIEntry ::= SEQUENCE { com2pm1AIIndex Integer32, com2pm1AIName OCTET STRING, com2pm1AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.3.1.1 com2pm1AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm1AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.3.1.2 com2pm1AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm1AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.3.1.3 com2pm1AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm1AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.4 com2pm1AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.4.1 com2pm1AOEntry OBJECT-TYPE SYNTAX Com2pm1AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1AOIndex } ::= { com2pm1AOTable 1 } Com2pm1AOEntry ::= SEQUENCE { com2pm1AOIndex Integer32, com2pm1AOName OCTET STRING, com2pm1AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.4.1.1 com2pm1AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm1AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.4.1.2 com2pm1AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm1AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.3.4.1.3 com2pm1AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm1AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.4 com2pm1HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm1HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm1 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.4.1 com2pm1HarmonicEntry OBJECT-TYPE SYNTAX Com2pm1HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm1HarmonicSubmeterIndex } ::= { com2pm1HarmonicTable 1 } Com2pm1HarmonicEntry ::= SEQUENCE { com2pm1HarmonicSubmeterIndex Integer32, com2pm1HarmonicSelector Integer32, com2pm1HarmonicVTHD Opaque, com2pm1HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.4.1.1 com2pm1HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm1HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.4.1.2 com2pm1HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm1HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.4.1.3 com2pm1HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm1HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.1.4.1.4 com2pm1HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm1HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2 com2pm2 OBJECT IDENTIFIER ::= { com2pm 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1 com2pm2BasicInfo OBJECT IDENTIFIER ::= { com2pm2 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.1 com2pm2Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm2BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.2 com2pm2Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm2BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.3 com2pm2ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm2BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.4 com2pm2Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm2BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.5 com2pm2PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.5.1 com2pm2PtEntry OBJECT-TYPE SYNTAX Com2pm2PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2PtIndex } ::= { com2pm2PtTable 1 } Com2pm2PtEntry ::= SEQUENCE { com2pm2PtIndex Integer32, com2pm2PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.5.1.1 com2pm2PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm2PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.5.1.2 com2pm2PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm2PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.6 com2pm2CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.6.1 com2pm2CtEntry OBJECT-TYPE SYNTAX Com2pm2CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2CtIndex } ::= { com2pm2CtTable 1 } Com2pm2CtEntry ::= SEQUENCE { com2pm2CtIndex Integer32, com2pm2CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.6.1.1 com2pm2CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm2CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.6.1.2 com2pm2CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm2CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.9 com2pm2DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm2BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.10 com2pm2DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm2BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.11 com2pm2AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm2BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.12 com2pm2AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm2BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.13 com2pm2PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm2BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.14 com2pm2RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm2BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.15 com2pm2ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm2BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.1.16 com2pm2StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm2BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2 com2pm2ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1 com2pm2ChEntry OBJECT-TYPE SYNTAX Com2pm2ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2ChSubmeterIndex } ::= { com2pm2ChTable 1 } Com2pm2ChEntry ::= SEQUENCE { com2pm2ChSubmeterIndex Integer32, com2pm2ChName OCTET STRING, com2pm2ChVoltage Opaque, com2pm2ChCurrent Opaque, com2pm2ChKW Opaque, com2pm2ChKvar Opaque, com2pm2ChKVA Opaque, com2pm2ChPF Opaque, com2pm2ChKWh Opaque, com2pm2ChKvarh Opaque, com2pm2ChKVAh Opaque, com2pm2ChActualDemand Opaque, com2pm2ChForecastDemand Opaque, com2pm2ChMaxDemandH Opaque, com2pm2ChMaxDemandD Opaque, com2pm2ChMaxDemandM Opaque, com2pm2ChElectricityD Opaque, com2pm2ChElectricityM Opaque, com2pm2ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.0 com2pm2ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm2ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.1 com2pm2ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm2ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.2 com2pm2ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm2ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.3 com2pm2ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm2ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.4 com2pm2ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm2ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.5 com2pm2ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm2ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.6 com2pm2ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm2ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.7 com2pm2ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm2ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.8 com2pm2ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm2ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.9 com2pm2ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm2ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.10 com2pm2ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm2ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.11 com2pm2ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm2ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.12 com2pm2ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm2ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.13 com2pm2ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm2ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.14 com2pm2ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm2ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.15 com2pm2ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm2ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.16 com2pm2ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm2ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.17 com2pm2ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm2ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.2.1.18 com2pm2ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm2ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3 com2pm2IOinfo OBJECT IDENTIFIER ::= { com2pm2 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.1 com2pm2DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.1.1 com2pm2DIEntry OBJECT-TYPE SYNTAX Com2pm2DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2DIIndex } ::= { com2pm2DITable 1 } Com2pm2DIEntry ::= SEQUENCE { com2pm2DIIndex Integer32, com2pm2DIName OCTET STRING, com2pm2DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.1.1.1 com2pm2DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm2DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.1.1.2 com2pm2DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm2DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.1.1.3 com2pm2DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm2DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.2 com2pm2DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.2.1 com2pm2DOEntry OBJECT-TYPE SYNTAX Com2pm2DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2DOIndex } ::= { com2pm2DOTable 1 } Com2pm2DOEntry ::= SEQUENCE { com2pm2DOIndex Integer32, com2pm2DOName OCTET STRING, com2pm2DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.2.1.1 com2pm2DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm2DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.2.1.2 com2pm2DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm2DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.2.1.3 com2pm2DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm2DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.3 com2pm2AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.3.1 com2pm2AIEntry OBJECT-TYPE SYNTAX Com2pm2AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2AIIndex } ::= { com2pm2AITable 1 } Com2pm2AIEntry ::= SEQUENCE { com2pm2AIIndex Integer32, com2pm2AIName OCTET STRING, com2pm2AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.3.1.1 com2pm2AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm2AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.3.1.2 com2pm2AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm2AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.3.1.3 com2pm2AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm2AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.4 com2pm2AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.4.1 com2pm2AOEntry OBJECT-TYPE SYNTAX Com2pm2AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2AOIndex } ::= { com2pm2AOTable 1 } Com2pm2AOEntry ::= SEQUENCE { com2pm2AOIndex Integer32, com2pm2AOName OCTET STRING, com2pm2AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.4.1.1 com2pm2AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm2AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.4.1.2 com2pm2AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm2AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.3.4.1.3 com2pm2AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm2AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.4 com2pm2HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm2HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm2 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.4.1 com2pm2HarmonicEntry OBJECT-TYPE SYNTAX Com2pm2HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm2HarmonicSubmeterIndex } ::= { com2pm2HarmonicTable 1 } Com2pm2HarmonicEntry ::= SEQUENCE { com2pm2HarmonicSubmeterIndex Integer32, com2pm2HarmonicSelector Integer32, com2pm2HarmonicVTHD Opaque, com2pm2HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.4.1.1 com2pm2HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm2HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.4.1.2 com2pm2HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm2HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.4.1.3 com2pm2HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm2HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.2.4.1.4 com2pm2HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm2HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3 com2pm3 OBJECT IDENTIFIER ::= { com2pm 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1 com2pm3BasicInfo OBJECT IDENTIFIER ::= { com2pm3 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.1 com2pm3Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm3BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.2 com2pm3Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm3BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.3 com2pm3ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm3BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.4 com2pm3Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm3BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.5 com2pm3PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.5.1 com2pm3PtEntry OBJECT-TYPE SYNTAX Com2pm3PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3PtIndex } ::= { com2pm3PtTable 1 } Com2pm3PtEntry ::= SEQUENCE { com2pm3PtIndex Integer32, com2pm3PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.5.1.1 com2pm3PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm3PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.5.1.2 com2pm3PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm3PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.6 com2pm3CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.6.1 com2pm3CtEntry OBJECT-TYPE SYNTAX Com2pm3CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3CtIndex } ::= { com2pm3CtTable 1 } Com2pm3CtEntry ::= SEQUENCE { com2pm3CtIndex Integer32, com2pm3CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.6.1.1 com2pm3CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm3CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.6.1.2 com2pm3CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm3CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.9 com2pm3DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm3BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.10 com2pm3DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm3BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.11 com2pm3AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm3BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.12 com2pm3AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm3BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.13 com2pm3PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm3BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.14 com2pm3RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm3BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.15 com2pm3ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm3BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.1.16 com2pm3StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm3BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2 com2pm3ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1 com2pm3ChEntry OBJECT-TYPE SYNTAX Com2pm3ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3ChSubmeterIndex } ::= { com2pm3ChTable 1 } Com2pm3ChEntry ::= SEQUENCE { com2pm3ChSubmeterIndex Integer32, com2pm3ChName OCTET STRING, com2pm3ChVoltage Opaque, com2pm3ChCurrent Opaque, com2pm3ChKW Opaque, com2pm3ChKvar Opaque, com2pm3ChKVA Opaque, com2pm3ChPF Opaque, com2pm3ChKWh Opaque, com2pm3ChKvarh Opaque, com2pm3ChKVAh Opaque, com2pm3ChActualDemand Opaque, com2pm3ChForecastDemand Opaque, com2pm3ChMaxDemandH Opaque, com2pm3ChMaxDemandD Opaque, com2pm3ChMaxDemandM Opaque, com2pm3ChElectricityD Opaque, com2pm3ChElectricityM Opaque, com2pm3ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.0 com2pm3ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm3ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.1 com2pm3ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm3ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.2 com2pm3ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm3ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.3 com2pm3ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm3ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.4 com2pm3ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm3ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.5 com2pm3ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm3ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.6 com2pm3ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm3ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.7 com2pm3ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm3ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.8 com2pm3ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm3ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.9 com2pm3ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm3ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.10 com2pm3ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm3ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.11 com2pm3ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm3ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.12 com2pm3ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm3ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.13 com2pm3ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm3ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.14 com2pm3ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm3ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.15 com2pm3ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm3ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.16 com2pm3ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm3ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.17 com2pm3ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm3ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.2.1.18 com2pm3ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm3ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3 com2pm3IOinfo OBJECT IDENTIFIER ::= { com2pm3 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.1 com2pm3DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.1.1 com2pm3DIEntry OBJECT-TYPE SYNTAX Com2pm3DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3DIIndex } ::= { com2pm3DITable 1 } Com2pm3DIEntry ::= SEQUENCE { com2pm3DIIndex Integer32, com2pm3DIName OCTET STRING, com2pm3DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.1.1.1 com2pm3DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm3DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.1.1.2 com2pm3DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm3DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.1.1.3 com2pm3DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm3DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.2 com2pm3DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.2.1 com2pm3DOEntry OBJECT-TYPE SYNTAX Com2pm3DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3DOIndex } ::= { com2pm3DOTable 1 } Com2pm3DOEntry ::= SEQUENCE { com2pm3DOIndex Integer32, com2pm3DOName OCTET STRING, com2pm3DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.2.1.1 com2pm3DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm3DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.2.1.2 com2pm3DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm3DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.2.1.3 com2pm3DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm3DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.3 com2pm3AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.3.1 com2pm3AIEntry OBJECT-TYPE SYNTAX Com2pm3AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3AIIndex } ::= { com2pm3AITable 1 } Com2pm3AIEntry ::= SEQUENCE { com2pm3AIIndex Integer32, com2pm3AIName OCTET STRING, com2pm3AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.3.1.1 com2pm3AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm3AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.3.1.2 com2pm3AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm3AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.3.1.3 com2pm3AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm3AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.4 com2pm3AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.4.1 com2pm3AOEntry OBJECT-TYPE SYNTAX Com2pm3AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3AOIndex } ::= { com2pm3AOTable 1 } Com2pm3AOEntry ::= SEQUENCE { com2pm3AOIndex Integer32, com2pm3AOName OCTET STRING, com2pm3AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.4.1.1 com2pm3AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm3AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.4.1.2 com2pm3AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm3AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.3.4.1.3 com2pm3AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm3AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.4 com2pm3HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm3HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm3 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.4.1 com2pm3HarmonicEntry OBJECT-TYPE SYNTAX Com2pm3HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm3HarmonicSubmeterIndex } ::= { com2pm3HarmonicTable 1 } Com2pm3HarmonicEntry ::= SEQUENCE { com2pm3HarmonicSubmeterIndex Integer32, com2pm3HarmonicSelector Integer32, com2pm3HarmonicVTHD Opaque, com2pm3HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.4.1.1 com2pm3HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm3HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.4.1.2 com2pm3HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm3HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.4.1.3 com2pm3HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm3HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.3.4.1.4 com2pm3HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm3HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4 com2pm4 OBJECT IDENTIFIER ::= { com2pm 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1 com2pm4BasicInfo OBJECT IDENTIFIER ::= { com2pm4 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.1 com2pm4Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm4BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.2 com2pm4Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm4BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.3 com2pm4ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm4BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.4 com2pm4Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm4BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.5 com2pm4PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.5.1 com2pm4PtEntry OBJECT-TYPE SYNTAX Com2pm4PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4PtIndex } ::= { com2pm4PtTable 1 } Com2pm4PtEntry ::= SEQUENCE { com2pm4PtIndex Integer32, com2pm4PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.5.1.1 com2pm4PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm4PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.5.1.2 com2pm4PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm4PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.6 com2pm4CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.6.1 com2pm4CtEntry OBJECT-TYPE SYNTAX Com2pm4CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4CtIndex } ::= { com2pm4CtTable 1 } Com2pm4CtEntry ::= SEQUENCE { com2pm4CtIndex Integer32, com2pm4CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.6.1.1 com2pm4CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm4CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.6.1.2 com2pm4CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm4CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.9 com2pm4DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm4BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.10 com2pm4DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm4BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.11 com2pm4AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm4BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.12 com2pm4AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm4BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.13 com2pm4PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm4BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.14 com2pm4RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm4BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.15 com2pm4ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm4BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.1.16 com2pm4StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm4BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2 com2pm4ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1 com2pm4ChEntry OBJECT-TYPE SYNTAX Com2pm4ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4ChSubmeterIndex } ::= { com2pm4ChTable 1 } Com2pm4ChEntry ::= SEQUENCE { com2pm4ChSubmeterIndex Integer32, com2pm4ChName OCTET STRING, com2pm4ChVoltage Opaque, com2pm4ChCurrent Opaque, com2pm4ChKW Opaque, com2pm4ChKvar Opaque, com2pm4ChKVA Opaque, com2pm4ChPF Opaque, com2pm4ChKWh Opaque, com2pm4ChKvarh Opaque, com2pm4ChKVAh Opaque, com2pm4ChActualDemand Opaque, com2pm4ChForecastDemand Opaque, com2pm4ChMaxDemandH Opaque, com2pm4ChMaxDemandD Opaque, com2pm4ChMaxDemandM Opaque, com2pm4ChElectricityD Opaque, com2pm4ChElectricityM Opaque, com2pm4ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.0 com2pm4ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm4ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.1 com2pm4ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm4ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.2 com2pm4ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm4ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.3 com2pm4ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm4ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.4 com2pm4ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm4ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.5 com2pm4ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm4ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.6 com2pm4ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm4ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.7 com2pm4ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm4ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.8 com2pm4ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm4ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.9 com2pm4ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm4ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.10 com2pm4ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm4ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.11 com2pm4ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm4ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.12 com2pm4ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm4ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.13 com2pm4ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm4ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.14 com2pm4ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm4ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.15 com2pm4ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm4ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.16 com2pm4ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm4ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.17 com2pm4ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm4ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.2.1.18 com2pm4ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm4ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3 com2pm4IOinfo OBJECT IDENTIFIER ::= { com2pm4 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.1 com2pm4DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.1.1 com2pm4DIEntry OBJECT-TYPE SYNTAX Com2pm4DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4DIIndex } ::= { com2pm4DITable 1 } Com2pm4DIEntry ::= SEQUENCE { com2pm4DIIndex Integer32, com2pm4DIName OCTET STRING, com2pm4DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.1.1.1 com2pm4DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm4DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.1.1.2 com2pm4DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm4DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.1.1.3 com2pm4DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm4DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.2 com2pm4DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.2.1 com2pm4DOEntry OBJECT-TYPE SYNTAX Com2pm4DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4DOIndex } ::= { com2pm4DOTable 1 } Com2pm4DOEntry ::= SEQUENCE { com2pm4DOIndex Integer32, com2pm4DOName OCTET STRING, com2pm4DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.2.1.1 com2pm4DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm4DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.2.1.2 com2pm4DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm4DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.2.1.3 com2pm4DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm4DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.3 com2pm4AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.3.1 com2pm4AIEntry OBJECT-TYPE SYNTAX Com2pm4AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4AIIndex } ::= { com2pm4AITable 1 } Com2pm4AIEntry ::= SEQUENCE { com2pm4AIIndex Integer32, com2pm4AIName OCTET STRING, com2pm4AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.3.1.1 com2pm4AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm4AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.3.1.2 com2pm4AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm4AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.3.1.3 com2pm4AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm4AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.4 com2pm4AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.4.1 com2pm4AOEntry OBJECT-TYPE SYNTAX Com2pm4AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4AOIndex } ::= { com2pm4AOTable 1 } Com2pm4AOEntry ::= SEQUENCE { com2pm4AOIndex Integer32, com2pm4AOName OCTET STRING, com2pm4AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.4.1.1 com2pm4AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm4AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.4.1.2 com2pm4AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm4AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.3.4.1.3 com2pm4AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm4AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.4 com2pm4HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm4HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm4 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.4.1 com2pm4HarmonicEntry OBJECT-TYPE SYNTAX Com2pm4HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm4HarmonicSubmeterIndex } ::= { com2pm4HarmonicTable 1 } Com2pm4HarmonicEntry ::= SEQUENCE { com2pm4HarmonicSubmeterIndex Integer32, com2pm4HarmonicSelector Integer32, com2pm4HarmonicVTHD Opaque, com2pm4HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.4.1.1 com2pm4HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm4HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.4.1.2 com2pm4HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm4HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.4.1.3 com2pm4HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm4HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.4.4.1.4 com2pm4HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm4HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5 com2pm5 OBJECT IDENTIFIER ::= { com2pm 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1 com2pm5BasicInfo OBJECT IDENTIFIER ::= { com2pm5 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.1 com2pm5Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm5BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.2 com2pm5Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm5BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.3 com2pm5ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm5BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.4 com2pm5Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm5BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.5 com2pm5PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.5.1 com2pm5PtEntry OBJECT-TYPE SYNTAX Com2pm5PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5PtIndex } ::= { com2pm5PtTable 1 } Com2pm5PtEntry ::= SEQUENCE { com2pm5PtIndex Integer32, com2pm5PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.5.1.1 com2pm5PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm5PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.5.1.2 com2pm5PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm5PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.6 com2pm5CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.6.1 com2pm5CtEntry OBJECT-TYPE SYNTAX Com2pm5CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5CtIndex } ::= { com2pm5CtTable 1 } Com2pm5CtEntry ::= SEQUENCE { com2pm5CtIndex Integer32, com2pm5CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.6.1.1 com2pm5CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm5CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.6.1.2 com2pm5CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm5CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.9 com2pm5DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm5BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.10 com2pm5DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm5BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.11 com2pm5AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm5BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.12 com2pm5AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm5BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.13 com2pm5PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm5BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.14 com2pm5RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm5BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.15 com2pm5ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm5BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.1.16 com2pm5StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm5BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2 com2pm5ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1 com2pm5ChEntry OBJECT-TYPE SYNTAX Com2pm5ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5ChSubmeterIndex } ::= { com2pm5ChTable 1 } Com2pm5ChEntry ::= SEQUENCE { com2pm5ChSubmeterIndex Integer32, com2pm5ChName OCTET STRING, com2pm5ChVoltage Opaque, com2pm5ChCurrent Opaque, com2pm5ChKW Opaque, com2pm5ChKvar Opaque, com2pm5ChKVA Opaque, com2pm5ChPF Opaque, com2pm5ChKWh Opaque, com2pm5ChKvarh Opaque, com2pm5ChKVAh Opaque, com2pm5ChActualDemand Opaque, com2pm5ChForecastDemand Opaque, com2pm5ChMaxDemandH Opaque, com2pm5ChMaxDemandD Opaque, com2pm5ChMaxDemandM Opaque, com2pm5ChElectricityD Opaque, com2pm5ChElectricityM Opaque, com2pm5ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.0 com2pm5ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm5ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.1 com2pm5ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm5ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.2 com2pm5ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm5ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.3 com2pm5ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm5ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.4 com2pm5ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm5ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.5 com2pm5ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm5ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.6 com2pm5ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm5ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.7 com2pm5ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm5ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.8 com2pm5ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm5ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.9 com2pm5ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm5ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.10 com2pm5ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm5ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.11 com2pm5ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm5ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.12 com2pm5ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm5ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.13 com2pm5ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm5ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.14 com2pm5ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm5ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.15 com2pm5ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm5ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.16 com2pm5ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm5ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.17 com2pm5ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm5ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.2.1.18 com2pm5ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm5ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3 com2pm5IOinfo OBJECT IDENTIFIER ::= { com2pm5 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.1 com2pm5DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.1.1 com2pm5DIEntry OBJECT-TYPE SYNTAX Com2pm5DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5DIIndex } ::= { com2pm5DITable 1 } Com2pm5DIEntry ::= SEQUENCE { com2pm5DIIndex Integer32, com2pm5DIName OCTET STRING, com2pm5DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.1.1.1 com2pm5DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm5DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.1.1.2 com2pm5DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm5DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.1.1.3 com2pm5DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm5DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.2 com2pm5DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.2.1 com2pm5DOEntry OBJECT-TYPE SYNTAX Com2pm5DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5DOIndex } ::= { com2pm5DOTable 1 } Com2pm5DOEntry ::= SEQUENCE { com2pm5DOIndex Integer32, com2pm5DOName OCTET STRING, com2pm5DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.2.1.1 com2pm5DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm5DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.2.1.2 com2pm5DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm5DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.2.1.3 com2pm5DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm5DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.3 com2pm5AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.3.1 com2pm5AIEntry OBJECT-TYPE SYNTAX Com2pm5AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5AIIndex } ::= { com2pm5AITable 1 } Com2pm5AIEntry ::= SEQUENCE { com2pm5AIIndex Integer32, com2pm5AIName OCTET STRING, com2pm5AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.3.1.1 com2pm5AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm5AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.3.1.2 com2pm5AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm5AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.3.1.3 com2pm5AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm5AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.4 com2pm5AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.4.1 com2pm5AOEntry OBJECT-TYPE SYNTAX Com2pm5AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5AOIndex } ::= { com2pm5AOTable 1 } Com2pm5AOEntry ::= SEQUENCE { com2pm5AOIndex Integer32, com2pm5AOName OCTET STRING, com2pm5AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.4.1.1 com2pm5AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm5AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.4.1.2 com2pm5AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm5AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.3.4.1.3 com2pm5AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm5AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.4 com2pm5HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm5HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm5 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.4.1 com2pm5HarmonicEntry OBJECT-TYPE SYNTAX Com2pm5HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm5HarmonicSubmeterIndex } ::= { com2pm5HarmonicTable 1 } Com2pm5HarmonicEntry ::= SEQUENCE { com2pm5HarmonicSubmeterIndex Integer32, com2pm5HarmonicSelector Integer32, com2pm5HarmonicVTHD Opaque, com2pm5HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.4.1.1 com2pm5HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm5HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.4.1.2 com2pm5HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm5HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.4.1.3 com2pm5HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm5HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.5.4.1.4 com2pm5HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm5HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6 com2pm6 OBJECT IDENTIFIER ::= { com2pm 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1 com2pm6BasicInfo OBJECT IDENTIFIER ::= { com2pm6 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.1 com2pm6Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm6BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.2 com2pm6Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm6BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.3 com2pm6ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm6BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.4 com2pm6Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm6BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.5 com2pm6PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.5.1 com2pm6PtEntry OBJECT-TYPE SYNTAX Com2pm6PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6PtIndex } ::= { com2pm6PtTable 1 } Com2pm6PtEntry ::= SEQUENCE { com2pm6PtIndex Integer32, com2pm6PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.5.1.1 com2pm6PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm6PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.5.1.2 com2pm6PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm6PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.6 com2pm6CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.6.1 com2pm6CtEntry OBJECT-TYPE SYNTAX Com2pm6CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6CtIndex } ::= { com2pm6CtTable 1 } Com2pm6CtEntry ::= SEQUENCE { com2pm6CtIndex Integer32, com2pm6CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.6.1.1 com2pm6CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm6CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.6.1.2 com2pm6CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm6CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.9 com2pm6DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm6BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.10 com2pm6DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm6BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.11 com2pm6AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm6BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.12 com2pm6AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm6BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.13 com2pm6PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm6BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.14 com2pm6RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm6BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.15 com2pm6ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm6BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.1.16 com2pm6StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm6BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2 com2pm6ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1 com2pm6ChEntry OBJECT-TYPE SYNTAX Com2pm6ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6ChSubmeterIndex } ::= { com2pm6ChTable 1 } Com2pm6ChEntry ::= SEQUENCE { com2pm6ChSubmeterIndex Integer32, com2pm6ChName OCTET STRING, com2pm6ChVoltage Opaque, com2pm6ChCurrent Opaque, com2pm6ChKW Opaque, com2pm6ChKvar Opaque, com2pm6ChKVA Opaque, com2pm6ChPF Opaque, com2pm6ChKWh Opaque, com2pm6ChKvarh Opaque, com2pm6ChKVAh Opaque, com2pm6ChActualDemand Opaque, com2pm6ChForecastDemand Opaque, com2pm6ChMaxDemandH Opaque, com2pm6ChMaxDemandD Opaque, com2pm6ChMaxDemandM Opaque, com2pm6ChElectricityD Opaque, com2pm6ChElectricityM Opaque, com2pm6ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.0 com2pm6ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm6ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.1 com2pm6ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm6ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.2 com2pm6ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm6ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.3 com2pm6ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm6ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.4 com2pm6ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm6ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.5 com2pm6ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm6ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.6 com2pm6ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm6ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.7 com2pm6ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm6ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.8 com2pm6ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm6ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.9 com2pm6ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm6ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.10 com2pm6ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm6ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.11 com2pm6ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm6ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.12 com2pm6ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm6ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.13 com2pm6ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm6ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.14 com2pm6ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm6ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.15 com2pm6ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm6ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.16 com2pm6ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm6ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.17 com2pm6ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm6ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.2.1.18 com2pm6ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm6ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3 com2pm6IOinfo OBJECT IDENTIFIER ::= { com2pm6 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.1 com2pm6DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.1.1 com2pm6DIEntry OBJECT-TYPE SYNTAX Com2pm6DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6DIIndex } ::= { com2pm6DITable 1 } Com2pm6DIEntry ::= SEQUENCE { com2pm6DIIndex Integer32, com2pm6DIName OCTET STRING, com2pm6DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.1.1.1 com2pm6DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm6DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.1.1.2 com2pm6DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm6DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.1.1.3 com2pm6DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm6DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.2 com2pm6DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.2.1 com2pm6DOEntry OBJECT-TYPE SYNTAX Com2pm6DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6DOIndex } ::= { com2pm6DOTable 1 } Com2pm6DOEntry ::= SEQUENCE { com2pm6DOIndex Integer32, com2pm6DOName OCTET STRING, com2pm6DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.2.1.1 com2pm6DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm6DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.2.1.2 com2pm6DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm6DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.2.1.3 com2pm6DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm6DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.3 com2pm6AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.3.1 com2pm6AIEntry OBJECT-TYPE SYNTAX Com2pm6AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6AIIndex } ::= { com2pm6AITable 1 } Com2pm6AIEntry ::= SEQUENCE { com2pm6AIIndex Integer32, com2pm6AIName OCTET STRING, com2pm6AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.3.1.1 com2pm6AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm6AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.3.1.2 com2pm6AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm6AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.3.1.3 com2pm6AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm6AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.4 com2pm6AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.4.1 com2pm6AOEntry OBJECT-TYPE SYNTAX Com2pm6AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6AOIndex } ::= { com2pm6AOTable 1 } Com2pm6AOEntry ::= SEQUENCE { com2pm6AOIndex Integer32, com2pm6AOName OCTET STRING, com2pm6AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.4.1.1 com2pm6AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm6AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.4.1.2 com2pm6AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm6AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.3.4.1.3 com2pm6AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm6AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.4 com2pm6HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm6HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm6 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.4.1 com2pm6HarmonicEntry OBJECT-TYPE SYNTAX Com2pm6HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm6HarmonicSubmeterIndex } ::= { com2pm6HarmonicTable 1 } Com2pm6HarmonicEntry ::= SEQUENCE { com2pm6HarmonicSubmeterIndex Integer32, com2pm6HarmonicSelector Integer32, com2pm6HarmonicVTHD Opaque, com2pm6HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.4.1.1 com2pm6HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm6HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.4.1.2 com2pm6HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm6HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.4.1.3 com2pm6HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm6HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.6.4.1.4 com2pm6HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm6HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7 com2pm7 OBJECT IDENTIFIER ::= { com2pm 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1 com2pm7BasicInfo OBJECT IDENTIFIER ::= { com2pm7 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.1 com2pm7Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm7BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.2 com2pm7Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm7BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.3 com2pm7ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm7BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.4 com2pm7Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm7BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.5 com2pm7PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.5.1 com2pm7PtEntry OBJECT-TYPE SYNTAX Com2pm7PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7PtIndex } ::= { com2pm7PtTable 1 } Com2pm7PtEntry ::= SEQUENCE { com2pm7PtIndex Integer32, com2pm7PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.5.1.1 com2pm7PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm7PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.5.1.2 com2pm7PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm7PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.6 com2pm7CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.6.1 com2pm7CtEntry OBJECT-TYPE SYNTAX Com2pm7CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7CtIndex } ::= { com2pm7CtTable 1 } Com2pm7CtEntry ::= SEQUENCE { com2pm7CtIndex Integer32, com2pm7CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.6.1.1 com2pm7CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm7CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.6.1.2 com2pm7CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm7CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.9 com2pm7DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm7BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.10 com2pm7DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm7BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.11 com2pm7AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm7BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.12 com2pm7AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm7BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.13 com2pm7PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm7BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.14 com2pm7RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm7BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.15 com2pm7ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm7BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.1.16 com2pm7StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm7BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2 com2pm7ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1 com2pm7ChEntry OBJECT-TYPE SYNTAX Com2pm7ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7ChSubmeterIndex } ::= { com2pm7ChTable 1 } Com2pm7ChEntry ::= SEQUENCE { com2pm7ChSubmeterIndex Integer32, com2pm7ChName OCTET STRING, com2pm7ChVoltage Opaque, com2pm7ChCurrent Opaque, com2pm7ChKW Opaque, com2pm7ChKvar Opaque, com2pm7ChKVA Opaque, com2pm7ChPF Opaque, com2pm7ChKWh Opaque, com2pm7ChKvarh Opaque, com2pm7ChKVAh Opaque, com2pm7ChActualDemand Opaque, com2pm7ChForecastDemand Opaque, com2pm7ChMaxDemandH Opaque, com2pm7ChMaxDemandD Opaque, com2pm7ChMaxDemandM Opaque, com2pm7ChElectricityD Opaque, com2pm7ChElectricityM Opaque, com2pm7ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.0 com2pm7ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm7ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.1 com2pm7ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm7ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.2 com2pm7ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm7ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.3 com2pm7ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm7ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.4 com2pm7ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm7ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.5 com2pm7ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm7ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.6 com2pm7ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm7ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.7 com2pm7ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm7ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.8 com2pm7ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm7ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.9 com2pm7ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm7ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.10 com2pm7ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm7ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.11 com2pm7ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm7ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.12 com2pm7ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm7ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.13 com2pm7ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm7ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.14 com2pm7ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm7ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.15 com2pm7ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm7ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.16 com2pm7ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm7ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.17 com2pm7ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm7ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.2.1.18 com2pm7ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm7ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3 com2pm7IOinfo OBJECT IDENTIFIER ::= { com2pm7 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.1 com2pm7DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.1.1 com2pm7DIEntry OBJECT-TYPE SYNTAX Com2pm7DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7DIIndex } ::= { com2pm7DITable 1 } Com2pm7DIEntry ::= SEQUENCE { com2pm7DIIndex Integer32, com2pm7DIName OCTET STRING, com2pm7DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.1.1.1 com2pm7DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm7DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.1.1.2 com2pm7DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm7DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.1.1.3 com2pm7DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm7DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.2 com2pm7DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.2.1 com2pm7DOEntry OBJECT-TYPE SYNTAX Com2pm7DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7DOIndex } ::= { com2pm7DOTable 1 } Com2pm7DOEntry ::= SEQUENCE { com2pm7DOIndex Integer32, com2pm7DOName OCTET STRING, com2pm7DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.2.1.1 com2pm7DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm7DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.2.1.2 com2pm7DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm7DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.2.1.3 com2pm7DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm7DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.3 com2pm7AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.3.1 com2pm7AIEntry OBJECT-TYPE SYNTAX Com2pm7AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7AIIndex } ::= { com2pm7AITable 1 } Com2pm7AIEntry ::= SEQUENCE { com2pm7AIIndex Integer32, com2pm7AIName OCTET STRING, com2pm7AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.3.1.1 com2pm7AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm7AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.3.1.2 com2pm7AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm7AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.3.1.3 com2pm7AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm7AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.4 com2pm7AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.4.1 com2pm7AOEntry OBJECT-TYPE SYNTAX Com2pm7AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7AOIndex } ::= { com2pm7AOTable 1 } Com2pm7AOEntry ::= SEQUENCE { com2pm7AOIndex Integer32, com2pm7AOName OCTET STRING, com2pm7AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.4.1.1 com2pm7AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm7AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.4.1.2 com2pm7AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm7AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.3.4.1.3 com2pm7AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm7AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.4 com2pm7HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm7HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm7 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.4.1 com2pm7HarmonicEntry OBJECT-TYPE SYNTAX Com2pm7HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm7HarmonicSubmeterIndex } ::= { com2pm7HarmonicTable 1 } Com2pm7HarmonicEntry ::= SEQUENCE { com2pm7HarmonicSubmeterIndex Integer32, com2pm7HarmonicSelector Integer32, com2pm7HarmonicVTHD Opaque, com2pm7HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.4.1.1 com2pm7HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm7HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.4.1.2 com2pm7HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm7HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.4.1.3 com2pm7HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm7HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.7.4.1.4 com2pm7HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm7HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8 com2pm8 OBJECT IDENTIFIER ::= { com2pm 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1 com2pm8BasicInfo OBJECT IDENTIFIER ::= { com2pm8 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.1 com2pm8Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm8BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.2 com2pm8Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm8BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.3 com2pm8ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm8BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.4 com2pm8Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm8BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.5 com2pm8PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.5.1 com2pm8PtEntry OBJECT-TYPE SYNTAX Com2pm8PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8PtIndex } ::= { com2pm8PtTable 1 } Com2pm8PtEntry ::= SEQUENCE { com2pm8PtIndex Integer32, com2pm8PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.5.1.1 com2pm8PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm8PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.5.1.2 com2pm8PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm8PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.6 com2pm8CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.6.1 com2pm8CtEntry OBJECT-TYPE SYNTAX Com2pm8CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8CtIndex } ::= { com2pm8CtTable 1 } Com2pm8CtEntry ::= SEQUENCE { com2pm8CtIndex Integer32, com2pm8CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.6.1.1 com2pm8CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm8CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.6.1.2 com2pm8CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm8CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.9 com2pm8DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm8BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.10 com2pm8DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm8BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.11 com2pm8AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm8BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.12 com2pm8AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm8BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.13 com2pm8PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm8BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.14 com2pm8RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm8BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.15 com2pm8ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm8BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.1.16 com2pm8StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm8BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2 com2pm8ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1 com2pm8ChEntry OBJECT-TYPE SYNTAX Com2pm8ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8ChSubmeterIndex } ::= { com2pm8ChTable 1 } Com2pm8ChEntry ::= SEQUENCE { com2pm8ChSubmeterIndex Integer32, com2pm8ChName OCTET STRING, com2pm8ChVoltage Opaque, com2pm8ChCurrent Opaque, com2pm8ChKW Opaque, com2pm8ChKvar Opaque, com2pm8ChKVA Opaque, com2pm8ChPF Opaque, com2pm8ChKWh Opaque, com2pm8ChKvarh Opaque, com2pm8ChKVAh Opaque, com2pm8ChActualDemand Opaque, com2pm8ChForecastDemand Opaque, com2pm8ChMaxDemandH Opaque, com2pm8ChMaxDemandD Opaque, com2pm8ChMaxDemandM Opaque, com2pm8ChElectricityD Opaque, com2pm8ChElectricityM Opaque, com2pm8ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.0 com2pm8ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm8ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.1 com2pm8ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm8ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.2 com2pm8ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm8ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.3 com2pm8ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm8ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.4 com2pm8ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm8ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.5 com2pm8ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm8ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.6 com2pm8ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm8ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.7 com2pm8ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm8ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.8 com2pm8ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm8ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.9 com2pm8ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm8ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.10 com2pm8ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm8ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.11 com2pm8ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm8ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.12 com2pm8ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm8ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.13 com2pm8ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm8ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.14 com2pm8ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm8ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.15 com2pm8ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm8ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.16 com2pm8ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm8ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.17 com2pm8ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm8ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.2.1.18 com2pm8ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm8ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3 com2pm8IOinfo OBJECT IDENTIFIER ::= { com2pm8 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.1 com2pm8DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.1.1 com2pm8DIEntry OBJECT-TYPE SYNTAX Com2pm8DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8DIIndex } ::= { com2pm8DITable 1 } Com2pm8DIEntry ::= SEQUENCE { com2pm8DIIndex Integer32, com2pm8DIName OCTET STRING, com2pm8DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.1.1.1 com2pm8DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm8DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.1.1.2 com2pm8DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm8DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.1.1.3 com2pm8DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm8DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.2 com2pm8DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.2.1 com2pm8DOEntry OBJECT-TYPE SYNTAX Com2pm8DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8DOIndex } ::= { com2pm8DOTable 1 } Com2pm8DOEntry ::= SEQUENCE { com2pm8DOIndex Integer32, com2pm8DOName OCTET STRING, com2pm8DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.2.1.1 com2pm8DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm8DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.2.1.2 com2pm8DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm8DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.2.1.3 com2pm8DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm8DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.3 com2pm8AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.3.1 com2pm8AIEntry OBJECT-TYPE SYNTAX Com2pm8AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8AIIndex } ::= { com2pm8AITable 1 } Com2pm8AIEntry ::= SEQUENCE { com2pm8AIIndex Integer32, com2pm8AIName OCTET STRING, com2pm8AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.3.1.1 com2pm8AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm8AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.3.1.2 com2pm8AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm8AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.3.1.3 com2pm8AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm8AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.4 com2pm8AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.4.1 com2pm8AOEntry OBJECT-TYPE SYNTAX Com2pm8AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8AOIndex } ::= { com2pm8AOTable 1 } Com2pm8AOEntry ::= SEQUENCE { com2pm8AOIndex Integer32, com2pm8AOName OCTET STRING, com2pm8AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.4.1.1 com2pm8AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm8AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.4.1.2 com2pm8AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm8AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.3.4.1.3 com2pm8AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm8AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.4 com2pm8HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm8HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm8 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.4.1 com2pm8HarmonicEntry OBJECT-TYPE SYNTAX Com2pm8HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm8HarmonicSubmeterIndex } ::= { com2pm8HarmonicTable 1 } Com2pm8HarmonicEntry ::= SEQUENCE { com2pm8HarmonicSubmeterIndex Integer32, com2pm8HarmonicSelector Integer32, com2pm8HarmonicVTHD Opaque, com2pm8HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.4.1.1 com2pm8HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm8HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.4.1.2 com2pm8HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm8HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.4.1.3 com2pm8HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm8HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.8.4.1.4 com2pm8HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm8HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9 com2pm9 OBJECT IDENTIFIER ::= { com2pm 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1 com2pm9BasicInfo OBJECT IDENTIFIER ::= { com2pm9 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.1 com2pm9Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm9BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.2 com2pm9Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm9BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.3 com2pm9ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm9BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.4 com2pm9Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm9BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.5 com2pm9PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.5.1 com2pm9PtEntry OBJECT-TYPE SYNTAX Com2pm9PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9PtIndex } ::= { com2pm9PtTable 1 } Com2pm9PtEntry ::= SEQUENCE { com2pm9PtIndex Integer32, com2pm9PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.5.1.1 com2pm9PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm9PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.5.1.2 com2pm9PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm9PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.6 com2pm9CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.6.1 com2pm9CtEntry OBJECT-TYPE SYNTAX Com2pm9CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9CtIndex } ::= { com2pm9CtTable 1 } Com2pm9CtEntry ::= SEQUENCE { com2pm9CtIndex Integer32, com2pm9CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.6.1.1 com2pm9CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm9CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.6.1.2 com2pm9CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm9CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.9 com2pm9DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm9BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.10 com2pm9DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm9BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.11 com2pm9AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm9BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.12 com2pm9AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm9BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.13 com2pm9PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm9BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.14 com2pm9RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm9BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.15 com2pm9ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm9BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.1.16 com2pm9StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm9BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2 com2pm9ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1 com2pm9ChEntry OBJECT-TYPE SYNTAX Com2pm9ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9ChSubmeterIndex } ::= { com2pm9ChTable 1 } Com2pm9ChEntry ::= SEQUENCE { com2pm9ChSubmeterIndex Integer32, com2pm9ChName OCTET STRING, com2pm9ChVoltage Opaque, com2pm9ChCurrent Opaque, com2pm9ChKW Opaque, com2pm9ChKvar Opaque, com2pm9ChKVA Opaque, com2pm9ChPF Opaque, com2pm9ChKWh Opaque, com2pm9ChKvarh Opaque, com2pm9ChKVAh Opaque, com2pm9ChActualDemand Opaque, com2pm9ChForecastDemand Opaque, com2pm9ChMaxDemandH Opaque, com2pm9ChMaxDemandD Opaque, com2pm9ChMaxDemandM Opaque, com2pm9ChElectricityD Opaque, com2pm9ChElectricityM Opaque, com2pm9ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.0 com2pm9ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm9ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.1 com2pm9ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm9ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.2 com2pm9ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm9ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.3 com2pm9ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm9ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.4 com2pm9ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm9ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.5 com2pm9ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm9ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.6 com2pm9ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm9ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.7 com2pm9ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm9ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.8 com2pm9ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm9ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.9 com2pm9ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm9ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.10 com2pm9ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm9ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.11 com2pm9ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm9ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.12 com2pm9ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm9ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.13 com2pm9ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm9ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.14 com2pm9ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm9ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.15 com2pm9ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm9ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.16 com2pm9ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm9ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.17 com2pm9ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm9ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.2.1.18 com2pm9ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm9ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3 com2pm9IOinfo OBJECT IDENTIFIER ::= { com2pm9 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.1 com2pm9DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.1.1 com2pm9DIEntry OBJECT-TYPE SYNTAX Com2pm9DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9DIIndex } ::= { com2pm9DITable 1 } Com2pm9DIEntry ::= SEQUENCE { com2pm9DIIndex Integer32, com2pm9DIName OCTET STRING, com2pm9DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.1.1.1 com2pm9DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm9DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.1.1.2 com2pm9DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm9DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.1.1.3 com2pm9DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm9DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.2 com2pm9DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.2.1 com2pm9DOEntry OBJECT-TYPE SYNTAX Com2pm9DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9DOIndex } ::= { com2pm9DOTable 1 } Com2pm9DOEntry ::= SEQUENCE { com2pm9DOIndex Integer32, com2pm9DOName OCTET STRING, com2pm9DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.2.1.1 com2pm9DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm9DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.2.1.2 com2pm9DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm9DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.2.1.3 com2pm9DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm9DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.3 com2pm9AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.3.1 com2pm9AIEntry OBJECT-TYPE SYNTAX Com2pm9AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9AIIndex } ::= { com2pm9AITable 1 } Com2pm9AIEntry ::= SEQUENCE { com2pm9AIIndex Integer32, com2pm9AIName OCTET STRING, com2pm9AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.3.1.1 com2pm9AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm9AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.3.1.2 com2pm9AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm9AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.3.1.3 com2pm9AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm9AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.4 com2pm9AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.4.1 com2pm9AOEntry OBJECT-TYPE SYNTAX Com2pm9AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9AOIndex } ::= { com2pm9AOTable 1 } Com2pm9AOEntry ::= SEQUENCE { com2pm9AOIndex Integer32, com2pm9AOName OCTET STRING, com2pm9AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.4.1.1 com2pm9AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm9AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.4.1.2 com2pm9AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm9AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.3.4.1.3 com2pm9AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm9AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.4 com2pm9HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm9HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm9 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.4.1 com2pm9HarmonicEntry OBJECT-TYPE SYNTAX Com2pm9HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm9HarmonicSubmeterIndex } ::= { com2pm9HarmonicTable 1 } Com2pm9HarmonicEntry ::= SEQUENCE { com2pm9HarmonicSubmeterIndex Integer32, com2pm9HarmonicSelector Integer32, com2pm9HarmonicVTHD Opaque, com2pm9HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.4.1.1 com2pm9HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm9HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.4.1.2 com2pm9HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm9HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.4.1.3 com2pm9HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm9HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.9.4.1.4 com2pm9HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm9HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10 com2pm10 OBJECT IDENTIFIER ::= { com2pm 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1 com2pm10BasicInfo OBJECT IDENTIFIER ::= { com2pm10 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.1 com2pm10Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm10BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.2 com2pm10Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm10BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.3 com2pm10ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm10BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.4 com2pm10Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm10BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.5 com2pm10PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.5.1 com2pm10PtEntry OBJECT-TYPE SYNTAX Com2pm10PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10PtIndex } ::= { com2pm10PtTable 1 } Com2pm10PtEntry ::= SEQUENCE { com2pm10PtIndex Integer32, com2pm10PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.5.1.1 com2pm10PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm10PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.5.1.2 com2pm10PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm10PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.6 com2pm10CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.6.1 com2pm10CtEntry OBJECT-TYPE SYNTAX Com2pm10CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10CtIndex } ::= { com2pm10CtTable 1 } Com2pm10CtEntry ::= SEQUENCE { com2pm10CtIndex Integer32, com2pm10CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.6.1.1 com2pm10CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm10CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.6.1.2 com2pm10CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm10CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.9 com2pm10DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm10BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.10 com2pm10DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm10BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.11 com2pm10AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm10BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.12 com2pm10AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm10BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.13 com2pm10PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm10BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.14 com2pm10RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm10BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.15 com2pm10ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm10BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.1.16 com2pm10StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm10BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2 com2pm10ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1 com2pm10ChEntry OBJECT-TYPE SYNTAX Com2pm10ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10ChSubmeterIndex } ::= { com2pm10ChTable 1 } Com2pm10ChEntry ::= SEQUENCE { com2pm10ChSubmeterIndex Integer32, com2pm10ChName OCTET STRING, com2pm10ChVoltage Opaque, com2pm10ChCurrent Opaque, com2pm10ChKW Opaque, com2pm10ChKvar Opaque, com2pm10ChKVA Opaque, com2pm10ChPF Opaque, com2pm10ChKWh Opaque, com2pm10ChKvarh Opaque, com2pm10ChKVAh Opaque, com2pm10ChActualDemand Opaque, com2pm10ChForecastDemand Opaque, com2pm10ChMaxDemandH Opaque, com2pm10ChMaxDemandD Opaque, com2pm10ChMaxDemandM Opaque, com2pm10ChElectricityD Opaque, com2pm10ChElectricityM Opaque, com2pm10ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.0 com2pm10ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm10ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.1 com2pm10ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm10ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.2 com2pm10ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm10ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.3 com2pm10ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm10ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.4 com2pm10ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm10ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.5 com2pm10ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm10ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.6 com2pm10ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm10ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.7 com2pm10ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm10ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.8 com2pm10ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm10ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.9 com2pm10ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm10ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.10 com2pm10ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm10ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.11 com2pm10ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm10ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.12 com2pm10ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm10ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.13 com2pm10ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm10ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.14 com2pm10ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm10ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.15 com2pm10ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm10ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.16 com2pm10ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm10ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.17 com2pm10ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm10ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.2.1.18 com2pm10ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm10ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3 com2pm10IOinfo OBJECT IDENTIFIER ::= { com2pm10 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.1 com2pm10DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.1.1 com2pm10DIEntry OBJECT-TYPE SYNTAX Com2pm10DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10DIIndex } ::= { com2pm10DITable 1 } Com2pm10DIEntry ::= SEQUENCE { com2pm10DIIndex Integer32, com2pm10DIName OCTET STRING, com2pm10DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.1.1.1 com2pm10DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm10DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.1.1.2 com2pm10DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm10DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.1.1.3 com2pm10DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm10DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.2 com2pm10DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.2.1 com2pm10DOEntry OBJECT-TYPE SYNTAX Com2pm10DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10DOIndex } ::= { com2pm10DOTable 1 } Com2pm10DOEntry ::= SEQUENCE { com2pm10DOIndex Integer32, com2pm10DOName OCTET STRING, com2pm10DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.2.1.1 com2pm10DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm10DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.2.1.2 com2pm10DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm10DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.2.1.3 com2pm10DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm10DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.3 com2pm10AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.3.1 com2pm10AIEntry OBJECT-TYPE SYNTAX Com2pm10AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10AIIndex } ::= { com2pm10AITable 1 } Com2pm10AIEntry ::= SEQUENCE { com2pm10AIIndex Integer32, com2pm10AIName OCTET STRING, com2pm10AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.3.1.1 com2pm10AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm10AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.3.1.2 com2pm10AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm10AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.3.1.3 com2pm10AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm10AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.4 com2pm10AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.4.1 com2pm10AOEntry OBJECT-TYPE SYNTAX Com2pm10AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10AOIndex } ::= { com2pm10AOTable 1 } Com2pm10AOEntry ::= SEQUENCE { com2pm10AOIndex Integer32, com2pm10AOName OCTET STRING, com2pm10AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.4.1.1 com2pm10AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm10AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.4.1.2 com2pm10AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm10AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.3.4.1.3 com2pm10AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm10AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.4 com2pm10HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm10HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm10 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.4.1 com2pm10HarmonicEntry OBJECT-TYPE SYNTAX Com2pm10HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm10HarmonicSubmeterIndex } ::= { com2pm10HarmonicTable 1 } Com2pm10HarmonicEntry ::= SEQUENCE { com2pm10HarmonicSubmeterIndex Integer32, com2pm10HarmonicSelector Integer32, com2pm10HarmonicVTHD Opaque, com2pm10HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.4.1.1 com2pm10HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm10HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.4.1.2 com2pm10HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm10HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.4.1.3 com2pm10HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm10HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.10.4.1.4 com2pm10HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm10HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11 com2pm11 OBJECT IDENTIFIER ::= { com2pm 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1 com2pm11BasicInfo OBJECT IDENTIFIER ::= { com2pm11 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.1 com2pm11Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm11BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.2 com2pm11Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm11BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.3 com2pm11ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm11BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.4 com2pm11Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm11BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.5 com2pm11PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.5.1 com2pm11PtEntry OBJECT-TYPE SYNTAX Com2pm11PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11PtIndex } ::= { com2pm11PtTable 1 } Com2pm11PtEntry ::= SEQUENCE { com2pm11PtIndex Integer32, com2pm11PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.5.1.1 com2pm11PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm11PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.5.1.2 com2pm11PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm11PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.6 com2pm11CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.6.1 com2pm11CtEntry OBJECT-TYPE SYNTAX Com2pm11CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11CtIndex } ::= { com2pm11CtTable 1 } Com2pm11CtEntry ::= SEQUENCE { com2pm11CtIndex Integer32, com2pm11CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.6.1.1 com2pm11CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm11CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.6.1.2 com2pm11CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm11CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.9 com2pm11DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm11BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.10 com2pm11DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm11BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.11 com2pm11AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm11BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.12 com2pm11AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm11BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.13 com2pm11PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm11BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.14 com2pm11RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm11BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.15 com2pm11ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm11BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.1.16 com2pm11StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm11BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2 com2pm11ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1 com2pm11ChEntry OBJECT-TYPE SYNTAX Com2pm11ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11ChSubmeterIndex } ::= { com2pm11ChTable 1 } Com2pm11ChEntry ::= SEQUENCE { com2pm11ChSubmeterIndex Integer32, com2pm11ChName OCTET STRING, com2pm11ChVoltage Opaque, com2pm11ChCurrent Opaque, com2pm11ChKW Opaque, com2pm11ChKvar Opaque, com2pm11ChKVA Opaque, com2pm11ChPF Opaque, com2pm11ChKWh Opaque, com2pm11ChKvarh Opaque, com2pm11ChKVAh Opaque, com2pm11ChActualDemand Opaque, com2pm11ChForecastDemand Opaque, com2pm11ChMaxDemandH Opaque, com2pm11ChMaxDemandD Opaque, com2pm11ChMaxDemandM Opaque, com2pm11ChElectricityD Opaque, com2pm11ChElectricityM Opaque, com2pm11ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.0 com2pm11ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm11ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.1 com2pm11ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm11ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.2 com2pm11ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm11ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.3 com2pm11ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm11ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.4 com2pm11ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm11ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.5 com2pm11ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm11ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.6 com2pm11ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm11ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.7 com2pm11ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm11ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.8 com2pm11ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm11ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.9 com2pm11ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm11ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.10 com2pm11ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm11ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.11 com2pm11ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm11ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.12 com2pm11ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm11ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.13 com2pm11ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm11ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.14 com2pm11ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm11ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.15 com2pm11ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm11ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.16 com2pm11ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm11ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.17 com2pm11ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm11ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.2.1.18 com2pm11ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm11ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3 com2pm11IOinfo OBJECT IDENTIFIER ::= { com2pm11 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.1 com2pm11DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.1.1 com2pm11DIEntry OBJECT-TYPE SYNTAX Com2pm11DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11DIIndex } ::= { com2pm11DITable 1 } Com2pm11DIEntry ::= SEQUENCE { com2pm11DIIndex Integer32, com2pm11DIName OCTET STRING, com2pm11DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.1.1.1 com2pm11DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm11DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.1.1.2 com2pm11DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm11DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.1.1.3 com2pm11DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm11DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.2 com2pm11DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.2.1 com2pm11DOEntry OBJECT-TYPE SYNTAX Com2pm11DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11DOIndex } ::= { com2pm11DOTable 1 } Com2pm11DOEntry ::= SEQUENCE { com2pm11DOIndex Integer32, com2pm11DOName OCTET STRING, com2pm11DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.2.1.1 com2pm11DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm11DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.2.1.2 com2pm11DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm11DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.2.1.3 com2pm11DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm11DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.3 com2pm11AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.3.1 com2pm11AIEntry OBJECT-TYPE SYNTAX Com2pm11AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11AIIndex } ::= { com2pm11AITable 1 } Com2pm11AIEntry ::= SEQUENCE { com2pm11AIIndex Integer32, com2pm11AIName OCTET STRING, com2pm11AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.3.1.1 com2pm11AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm11AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.3.1.2 com2pm11AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm11AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.3.1.3 com2pm11AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm11AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.4 com2pm11AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.4.1 com2pm11AOEntry OBJECT-TYPE SYNTAX Com2pm11AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11AOIndex } ::= { com2pm11AOTable 1 } Com2pm11AOEntry ::= SEQUENCE { com2pm11AOIndex Integer32, com2pm11AOName OCTET STRING, com2pm11AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.4.1.1 com2pm11AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm11AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.4.1.2 com2pm11AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm11AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.3.4.1.3 com2pm11AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm11AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.4 com2pm11HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm11HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm11 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.4.1 com2pm11HarmonicEntry OBJECT-TYPE SYNTAX Com2pm11HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm11HarmonicSubmeterIndex } ::= { com2pm11HarmonicTable 1 } Com2pm11HarmonicEntry ::= SEQUENCE { com2pm11HarmonicSubmeterIndex Integer32, com2pm11HarmonicSelector Integer32, com2pm11HarmonicVTHD Opaque, com2pm11HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.4.1.1 com2pm11HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm11HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.4.1.2 com2pm11HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm11HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.4.1.3 com2pm11HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm11HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.11.4.1.4 com2pm11HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm11HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12 com2pm12 OBJECT IDENTIFIER ::= { com2pm 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1 com2pm12BasicInfo OBJECT IDENTIFIER ::= { com2pm12 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.1 com2pm12Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm12BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.2 com2pm12Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm12BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.3 com2pm12ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm12BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.4 com2pm12Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm12BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.5 com2pm12PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.5.1 com2pm12PtEntry OBJECT-TYPE SYNTAX Com2pm12PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12PtIndex } ::= { com2pm12PtTable 1 } Com2pm12PtEntry ::= SEQUENCE { com2pm12PtIndex Integer32, com2pm12PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.5.1.1 com2pm12PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm12PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.5.1.2 com2pm12PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm12PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.6 com2pm12CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.6.1 com2pm12CtEntry OBJECT-TYPE SYNTAX Com2pm12CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12CtIndex } ::= { com2pm12CtTable 1 } Com2pm12CtEntry ::= SEQUENCE { com2pm12CtIndex Integer32, com2pm12CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.6.1.1 com2pm12CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm12CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.6.1.2 com2pm12CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm12CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.9 com2pm12DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm12BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.10 com2pm12DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm12BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.11 com2pm12AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm12BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.12 com2pm12AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm12BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.13 com2pm12PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm12BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.14 com2pm12RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm12BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.15 com2pm12ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm12BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.1.16 com2pm12StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm12BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2 com2pm12ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1 com2pm12ChEntry OBJECT-TYPE SYNTAX Com2pm12ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12ChSubmeterIndex } ::= { com2pm12ChTable 1 } Com2pm12ChEntry ::= SEQUENCE { com2pm12ChSubmeterIndex Integer32, com2pm12ChName OCTET STRING, com2pm12ChVoltage Opaque, com2pm12ChCurrent Opaque, com2pm12ChKW Opaque, com2pm12ChKvar Opaque, com2pm12ChKVA Opaque, com2pm12ChPF Opaque, com2pm12ChKWh Opaque, com2pm12ChKvarh Opaque, com2pm12ChKVAh Opaque, com2pm12ChActualDemand Opaque, com2pm12ChForecastDemand Opaque, com2pm12ChMaxDemandH Opaque, com2pm12ChMaxDemandD Opaque, com2pm12ChMaxDemandM Opaque, com2pm12ChElectricityD Opaque, com2pm12ChElectricityM Opaque, com2pm12ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.0 com2pm12ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm12ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.1 com2pm12ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm12ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.2 com2pm12ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm12ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.3 com2pm12ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm12ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.4 com2pm12ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm12ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.5 com2pm12ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm12ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.6 com2pm12ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm12ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.7 com2pm12ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm12ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.8 com2pm12ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm12ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.9 com2pm12ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm12ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.10 com2pm12ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm12ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.11 com2pm12ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm12ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.12 com2pm12ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm12ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.13 com2pm12ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm12ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.14 com2pm12ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm12ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.15 com2pm12ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm12ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.16 com2pm12ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm12ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.17 com2pm12ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm12ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.2.1.18 com2pm12ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm12ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3 com2pm12IOinfo OBJECT IDENTIFIER ::= { com2pm12 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.1 com2pm12DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.1.1 com2pm12DIEntry OBJECT-TYPE SYNTAX Com2pm12DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12DIIndex } ::= { com2pm12DITable 1 } Com2pm12DIEntry ::= SEQUENCE { com2pm12DIIndex Integer32, com2pm12DIName OCTET STRING, com2pm12DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.1.1.1 com2pm12DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm12DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.1.1.2 com2pm12DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm12DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.1.1.3 com2pm12DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm12DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.2 com2pm12DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.2.1 com2pm12DOEntry OBJECT-TYPE SYNTAX Com2pm12DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12DOIndex } ::= { com2pm12DOTable 1 } Com2pm12DOEntry ::= SEQUENCE { com2pm12DOIndex Integer32, com2pm12DOName OCTET STRING, com2pm12DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.2.1.1 com2pm12DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm12DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.2.1.2 com2pm12DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm12DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.2.1.3 com2pm12DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm12DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.3 com2pm12AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.3.1 com2pm12AIEntry OBJECT-TYPE SYNTAX Com2pm12AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12AIIndex } ::= { com2pm12AITable 1 } Com2pm12AIEntry ::= SEQUENCE { com2pm12AIIndex Integer32, com2pm12AIName OCTET STRING, com2pm12AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.3.1.1 com2pm12AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm12AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.3.1.2 com2pm12AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm12AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.3.1.3 com2pm12AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm12AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.4 com2pm12AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.4.1 com2pm12AOEntry OBJECT-TYPE SYNTAX Com2pm12AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12AOIndex } ::= { com2pm12AOTable 1 } Com2pm12AOEntry ::= SEQUENCE { com2pm12AOIndex Integer32, com2pm12AOName OCTET STRING, com2pm12AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.4.1.1 com2pm12AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm12AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.4.1.2 com2pm12AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm12AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.3.4.1.3 com2pm12AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm12AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.4 com2pm12HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm12HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm12 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.4.1 com2pm12HarmonicEntry OBJECT-TYPE SYNTAX Com2pm12HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm12HarmonicSubmeterIndex } ::= { com2pm12HarmonicTable 1 } Com2pm12HarmonicEntry ::= SEQUENCE { com2pm12HarmonicSubmeterIndex Integer32, com2pm12HarmonicSelector Integer32, com2pm12HarmonicVTHD Opaque, com2pm12HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.4.1.1 com2pm12HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm12HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.4.1.2 com2pm12HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm12HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.4.1.3 com2pm12HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm12HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.12.4.1.4 com2pm12HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm12HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13 com2pm13 OBJECT IDENTIFIER ::= { com2pm 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1 com2pm13BasicInfo OBJECT IDENTIFIER ::= { com2pm13 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.1 com2pm13Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm13BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.2 com2pm13Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm13BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.3 com2pm13ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm13BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.4 com2pm13Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm13BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.5 com2pm13PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.5.1 com2pm13PtEntry OBJECT-TYPE SYNTAX Com2pm13PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13PtIndex } ::= { com2pm13PtTable 1 } Com2pm13PtEntry ::= SEQUENCE { com2pm13PtIndex Integer32, com2pm13PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.5.1.1 com2pm13PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm13PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.5.1.2 com2pm13PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm13PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.6 com2pm13CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.6.1 com2pm13CtEntry OBJECT-TYPE SYNTAX Com2pm13CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13CtIndex } ::= { com2pm13CtTable 1 } Com2pm13CtEntry ::= SEQUENCE { com2pm13CtIndex Integer32, com2pm13CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.6.1.1 com2pm13CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm13CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.6.1.2 com2pm13CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm13CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.9 com2pm13DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm13BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.10 com2pm13DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm13BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.11 com2pm13AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm13BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.12 com2pm13AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm13BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.13 com2pm13PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm13BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.14 com2pm13RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm13BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.15 com2pm13ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm13BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.1.16 com2pm13StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm13BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2 com2pm13ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1 com2pm13ChEntry OBJECT-TYPE SYNTAX Com2pm13ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13ChSubmeterIndex } ::= { com2pm13ChTable 1 } Com2pm13ChEntry ::= SEQUENCE { com2pm13ChSubmeterIndex Integer32, com2pm13ChName OCTET STRING, com2pm13ChVoltage Opaque, com2pm13ChCurrent Opaque, com2pm13ChKW Opaque, com2pm13ChKvar Opaque, com2pm13ChKVA Opaque, com2pm13ChPF Opaque, com2pm13ChKWh Opaque, com2pm13ChKvarh Opaque, com2pm13ChKVAh Opaque, com2pm13ChActualDemand Opaque, com2pm13ChForecastDemand Opaque, com2pm13ChMaxDemandH Opaque, com2pm13ChMaxDemandD Opaque, com2pm13ChMaxDemandM Opaque, com2pm13ChElectricityD Opaque, com2pm13ChElectricityM Opaque, com2pm13ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.0 com2pm13ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm13ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.1 com2pm13ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm13ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.2 com2pm13ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm13ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.3 com2pm13ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm13ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.4 com2pm13ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm13ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.5 com2pm13ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm13ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.6 com2pm13ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm13ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.7 com2pm13ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm13ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.8 com2pm13ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm13ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.9 com2pm13ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm13ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.10 com2pm13ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm13ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.11 com2pm13ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm13ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.12 com2pm13ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm13ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.13 com2pm13ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm13ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.14 com2pm13ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm13ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.15 com2pm13ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm13ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.16 com2pm13ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm13ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.17 com2pm13ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm13ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.2.1.18 com2pm13ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm13ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3 com2pm13IOinfo OBJECT IDENTIFIER ::= { com2pm13 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.1 com2pm13DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.1.1 com2pm13DIEntry OBJECT-TYPE SYNTAX Com2pm13DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13DIIndex } ::= { com2pm13DITable 1 } Com2pm13DIEntry ::= SEQUENCE { com2pm13DIIndex Integer32, com2pm13DIName OCTET STRING, com2pm13DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.1.1.1 com2pm13DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm13DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.1.1.2 com2pm13DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm13DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.1.1.3 com2pm13DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm13DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.2 com2pm13DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.2.1 com2pm13DOEntry OBJECT-TYPE SYNTAX Com2pm13DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13DOIndex } ::= { com2pm13DOTable 1 } Com2pm13DOEntry ::= SEQUENCE { com2pm13DOIndex Integer32, com2pm13DOName OCTET STRING, com2pm13DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.2.1.1 com2pm13DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm13DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.2.1.2 com2pm13DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm13DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.2.1.3 com2pm13DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm13DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.3 com2pm13AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.3.1 com2pm13AIEntry OBJECT-TYPE SYNTAX Com2pm13AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13AIIndex } ::= { com2pm13AITable 1 } Com2pm13AIEntry ::= SEQUENCE { com2pm13AIIndex Integer32, com2pm13AIName OCTET STRING, com2pm13AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.3.1.1 com2pm13AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm13AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.3.1.2 com2pm13AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm13AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.3.1.3 com2pm13AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm13AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.4 com2pm13AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.4.1 com2pm13AOEntry OBJECT-TYPE SYNTAX Com2pm13AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13AOIndex } ::= { com2pm13AOTable 1 } Com2pm13AOEntry ::= SEQUENCE { com2pm13AOIndex Integer32, com2pm13AOName OCTET STRING, com2pm13AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.4.1.1 com2pm13AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm13AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.4.1.2 com2pm13AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm13AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.3.4.1.3 com2pm13AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm13AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.4 com2pm13HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm13HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm13 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.4.1 com2pm13HarmonicEntry OBJECT-TYPE SYNTAX Com2pm13HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm13HarmonicSubmeterIndex } ::= { com2pm13HarmonicTable 1 } Com2pm13HarmonicEntry ::= SEQUENCE { com2pm13HarmonicSubmeterIndex Integer32, com2pm13HarmonicSelector Integer32, com2pm13HarmonicVTHD Opaque, com2pm13HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.4.1.1 com2pm13HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm13HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.4.1.2 com2pm13HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm13HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.4.1.3 com2pm13HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm13HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.13.4.1.4 com2pm13HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm13HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14 com2pm14 OBJECT IDENTIFIER ::= { com2pm 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1 com2pm14BasicInfo OBJECT IDENTIFIER ::= { com2pm14 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.1 com2pm14Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm14BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.2 com2pm14Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm14BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.3 com2pm14ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm14BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.4 com2pm14Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm14BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.5 com2pm14PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.5.1 com2pm14PtEntry OBJECT-TYPE SYNTAX Com2pm14PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14PtIndex } ::= { com2pm14PtTable 1 } Com2pm14PtEntry ::= SEQUENCE { com2pm14PtIndex Integer32, com2pm14PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.5.1.1 com2pm14PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm14PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.5.1.2 com2pm14PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm14PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.6 com2pm14CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.6.1 com2pm14CtEntry OBJECT-TYPE SYNTAX Com2pm14CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14CtIndex } ::= { com2pm14CtTable 1 } Com2pm14CtEntry ::= SEQUENCE { com2pm14CtIndex Integer32, com2pm14CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.6.1.1 com2pm14CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm14CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.6.1.2 com2pm14CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm14CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.9 com2pm14DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm14BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.10 com2pm14DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm14BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.11 com2pm14AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm14BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.12 com2pm14AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm14BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.13 com2pm14PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm14BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.14 com2pm14RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm14BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.15 com2pm14ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm14BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.1.16 com2pm14StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm14BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2 com2pm14ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1 com2pm14ChEntry OBJECT-TYPE SYNTAX Com2pm14ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14ChSubmeterIndex } ::= { com2pm14ChTable 1 } Com2pm14ChEntry ::= SEQUENCE { com2pm14ChSubmeterIndex Integer32, com2pm14ChName OCTET STRING, com2pm14ChVoltage Opaque, com2pm14ChCurrent Opaque, com2pm14ChKW Opaque, com2pm14ChKvar Opaque, com2pm14ChKVA Opaque, com2pm14ChPF Opaque, com2pm14ChKWh Opaque, com2pm14ChKvarh Opaque, com2pm14ChKVAh Opaque, com2pm14ChActualDemand Opaque, com2pm14ChForecastDemand Opaque, com2pm14ChMaxDemandH Opaque, com2pm14ChMaxDemandD Opaque, com2pm14ChMaxDemandM Opaque, com2pm14ChElectricityD Opaque, com2pm14ChElectricityM Opaque, com2pm14ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.0 com2pm14ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm14ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.1 com2pm14ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm14ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.2 com2pm14ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm14ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.3 com2pm14ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm14ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.4 com2pm14ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm14ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.5 com2pm14ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm14ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.6 com2pm14ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm14ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.7 com2pm14ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm14ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.8 com2pm14ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm14ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.9 com2pm14ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm14ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.10 com2pm14ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm14ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.11 com2pm14ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm14ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.12 com2pm14ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm14ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.13 com2pm14ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm14ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.14 com2pm14ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm14ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.15 com2pm14ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm14ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.16 com2pm14ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm14ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.17 com2pm14ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm14ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.2.1.18 com2pm14ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm14ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3 com2pm14IOinfo OBJECT IDENTIFIER ::= { com2pm14 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.1 com2pm14DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.1.1 com2pm14DIEntry OBJECT-TYPE SYNTAX Com2pm14DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14DIIndex } ::= { com2pm14DITable 1 } Com2pm14DIEntry ::= SEQUENCE { com2pm14DIIndex Integer32, com2pm14DIName OCTET STRING, com2pm14DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.1.1.1 com2pm14DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm14DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.1.1.2 com2pm14DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm14DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.1.1.3 com2pm14DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm14DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.2 com2pm14DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.2.1 com2pm14DOEntry OBJECT-TYPE SYNTAX Com2pm14DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14DOIndex } ::= { com2pm14DOTable 1 } Com2pm14DOEntry ::= SEQUENCE { com2pm14DOIndex Integer32, com2pm14DOName OCTET STRING, com2pm14DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.2.1.1 com2pm14DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm14DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.2.1.2 com2pm14DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm14DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.2.1.3 com2pm14DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm14DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.3 com2pm14AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.3.1 com2pm14AIEntry OBJECT-TYPE SYNTAX Com2pm14AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14AIIndex } ::= { com2pm14AITable 1 } Com2pm14AIEntry ::= SEQUENCE { com2pm14AIIndex Integer32, com2pm14AIName OCTET STRING, com2pm14AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.3.1.1 com2pm14AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm14AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.3.1.2 com2pm14AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm14AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.3.1.3 com2pm14AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm14AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.4 com2pm14AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.4.1 com2pm14AOEntry OBJECT-TYPE SYNTAX Com2pm14AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14AOIndex } ::= { com2pm14AOTable 1 } Com2pm14AOEntry ::= SEQUENCE { com2pm14AOIndex Integer32, com2pm14AOName OCTET STRING, com2pm14AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.4.1.1 com2pm14AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm14AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.4.1.2 com2pm14AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm14AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.3.4.1.3 com2pm14AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm14AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.4 com2pm14HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm14HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm14 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.4.1 com2pm14HarmonicEntry OBJECT-TYPE SYNTAX Com2pm14HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm14HarmonicSubmeterIndex } ::= { com2pm14HarmonicTable 1 } Com2pm14HarmonicEntry ::= SEQUENCE { com2pm14HarmonicSubmeterIndex Integer32, com2pm14HarmonicSelector Integer32, com2pm14HarmonicVTHD Opaque, com2pm14HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.4.1.1 com2pm14HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm14HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.4.1.2 com2pm14HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm14HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.4.1.3 com2pm14HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm14HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.14.4.1.4 com2pm14HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm14HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15 com2pm15 OBJECT IDENTIFIER ::= { com2pm 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1 com2pm15BasicInfo OBJECT IDENTIFIER ::= { com2pm15 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.1 com2pm15Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm15BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.2 com2pm15Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm15BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.3 com2pm15ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm15BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.4 com2pm15Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm15BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.5 com2pm15PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.5.1 com2pm15PtEntry OBJECT-TYPE SYNTAX Com2pm15PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15PtIndex } ::= { com2pm15PtTable 1 } Com2pm15PtEntry ::= SEQUENCE { com2pm15PtIndex Integer32, com2pm15PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.5.1.1 com2pm15PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm15PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.5.1.2 com2pm15PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm15PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.6 com2pm15CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.6.1 com2pm15CtEntry OBJECT-TYPE SYNTAX Com2pm15CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15CtIndex } ::= { com2pm15CtTable 1 } Com2pm15CtEntry ::= SEQUENCE { com2pm15CtIndex Integer32, com2pm15CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.6.1.1 com2pm15CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm15CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.6.1.2 com2pm15CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm15CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.9 com2pm15DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm15BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.10 com2pm15DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm15BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.11 com2pm15AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm15BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.12 com2pm15AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm15BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.13 com2pm15PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm15BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.14 com2pm15RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm15BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.15 com2pm15ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm15BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.1.16 com2pm15StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm15BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2 com2pm15ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1 com2pm15ChEntry OBJECT-TYPE SYNTAX Com2pm15ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15ChSubmeterIndex } ::= { com2pm15ChTable 1 } Com2pm15ChEntry ::= SEQUENCE { com2pm15ChSubmeterIndex Integer32, com2pm15ChName OCTET STRING, com2pm15ChVoltage Opaque, com2pm15ChCurrent Opaque, com2pm15ChKW Opaque, com2pm15ChKvar Opaque, com2pm15ChKVA Opaque, com2pm15ChPF Opaque, com2pm15ChKWh Opaque, com2pm15ChKvarh Opaque, com2pm15ChKVAh Opaque, com2pm15ChActualDemand Opaque, com2pm15ChForecastDemand Opaque, com2pm15ChMaxDemandH Opaque, com2pm15ChMaxDemandD Opaque, com2pm15ChMaxDemandM Opaque, com2pm15ChElectricityD Opaque, com2pm15ChElectricityM Opaque, com2pm15ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.0 com2pm15ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm15ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.1 com2pm15ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm15ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.2 com2pm15ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm15ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.3 com2pm15ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm15ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.4 com2pm15ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm15ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.5 com2pm15ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm15ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.6 com2pm15ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm15ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.7 com2pm15ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm15ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.8 com2pm15ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm15ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.9 com2pm15ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm15ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.10 com2pm15ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm15ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.11 com2pm15ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm15ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.12 com2pm15ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm15ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.13 com2pm15ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm15ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.14 com2pm15ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm15ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.15 com2pm15ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm15ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.16 com2pm15ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm15ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.17 com2pm15ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm15ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.2.1.18 com2pm15ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm15ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3 com2pm15IOinfo OBJECT IDENTIFIER ::= { com2pm15 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.1 com2pm15DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.1.1 com2pm15DIEntry OBJECT-TYPE SYNTAX Com2pm15DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15DIIndex } ::= { com2pm15DITable 1 } Com2pm15DIEntry ::= SEQUENCE { com2pm15DIIndex Integer32, com2pm15DIName OCTET STRING, com2pm15DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.1.1.1 com2pm15DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm15DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.1.1.2 com2pm15DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm15DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.1.1.3 com2pm15DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm15DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.2 com2pm15DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.2.1 com2pm15DOEntry OBJECT-TYPE SYNTAX Com2pm15DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15DOIndex } ::= { com2pm15DOTable 1 } Com2pm15DOEntry ::= SEQUENCE { com2pm15DOIndex Integer32, com2pm15DOName OCTET STRING, com2pm15DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.2.1.1 com2pm15DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm15DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.2.1.2 com2pm15DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm15DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.2.1.3 com2pm15DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm15DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.3 com2pm15AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.3.1 com2pm15AIEntry OBJECT-TYPE SYNTAX Com2pm15AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15AIIndex } ::= { com2pm15AITable 1 } Com2pm15AIEntry ::= SEQUENCE { com2pm15AIIndex Integer32, com2pm15AIName OCTET STRING, com2pm15AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.3.1.1 com2pm15AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm15AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.3.1.2 com2pm15AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm15AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.3.1.3 com2pm15AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm15AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.4 com2pm15AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.4.1 com2pm15AOEntry OBJECT-TYPE SYNTAX Com2pm15AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15AOIndex } ::= { com2pm15AOTable 1 } Com2pm15AOEntry ::= SEQUENCE { com2pm15AOIndex Integer32, com2pm15AOName OCTET STRING, com2pm15AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.4.1.1 com2pm15AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm15AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.4.1.2 com2pm15AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm15AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.3.4.1.3 com2pm15AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm15AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.4 com2pm15HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm15HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm15 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.4.1 com2pm15HarmonicEntry OBJECT-TYPE SYNTAX Com2pm15HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm15HarmonicSubmeterIndex } ::= { com2pm15HarmonicTable 1 } Com2pm15HarmonicEntry ::= SEQUENCE { com2pm15HarmonicSubmeterIndex Integer32, com2pm15HarmonicSelector Integer32, com2pm15HarmonicVTHD Opaque, com2pm15HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.4.1.1 com2pm15HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm15HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.4.1.2 com2pm15HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm15HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.4.1.3 com2pm15HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm15HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.15.4.1.4 com2pm15HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm15HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16 com2pm16 OBJECT IDENTIFIER ::= { com2pm 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1 com2pm16BasicInfo OBJECT IDENTIFIER ::= { com2pm16 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.1 com2pm16Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { com2pm16BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.2 com2pm16Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { com2pm16BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.3 com2pm16ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { com2pm16BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.4 com2pm16Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { com2pm16BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.5 com2pm16PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.5.1 com2pm16PtEntry OBJECT-TYPE SYNTAX Com2pm16PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16PtIndex } ::= { com2pm16PtTable 1 } Com2pm16PtEntry ::= SEQUENCE { com2pm16PtIndex Integer32, com2pm16PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.5.1.1 com2pm16PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { com2pm16PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.5.1.2 com2pm16PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { com2pm16PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.6 com2pm16CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.6.1 com2pm16CtEntry OBJECT-TYPE SYNTAX Com2pm16CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16CtIndex } ::= { com2pm16CtTable 1 } Com2pm16CtEntry ::= SEQUENCE { com2pm16CtIndex Integer32, com2pm16CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.6.1.1 com2pm16CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { com2pm16CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.6.1.2 com2pm16CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { com2pm16CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.9 com2pm16DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { com2pm16BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.10 com2pm16DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { com2pm16BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.11 com2pm16AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { com2pm16BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.12 com2pm16AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { com2pm16BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.13 com2pm16PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { com2pm16BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.14 com2pm16RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { com2pm16BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.15 com2pm16ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { com2pm16BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.1.16 com2pm16StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { com2pm16BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2 com2pm16ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1 com2pm16ChEntry OBJECT-TYPE SYNTAX Com2pm16ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16ChSubmeterIndex } ::= { com2pm16ChTable 1 } Com2pm16ChEntry ::= SEQUENCE { com2pm16ChSubmeterIndex Integer32, com2pm16ChName OCTET STRING, com2pm16ChVoltage Opaque, com2pm16ChCurrent Opaque, com2pm16ChKW Opaque, com2pm16ChKvar Opaque, com2pm16ChKVA Opaque, com2pm16ChPF Opaque, com2pm16ChKWh Opaque, com2pm16ChKvarh Opaque, com2pm16ChKVAh Opaque, com2pm16ChActualDemand Opaque, com2pm16ChForecastDemand Opaque, com2pm16ChMaxDemandH Opaque, com2pm16ChMaxDemandD Opaque, com2pm16ChMaxDemandM Opaque, com2pm16ChElectricityD Opaque, com2pm16ChElectricityM Opaque, com2pm16ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.0 com2pm16ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm16ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.1 com2pm16ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { com2pm16ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.2 com2pm16ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { com2pm16ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.3 com2pm16ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { com2pm16ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.4 com2pm16ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { com2pm16ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.5 com2pm16ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { com2pm16ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.6 com2pm16ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { com2pm16ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.7 com2pm16ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { com2pm16ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.8 com2pm16ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { com2pm16ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.9 com2pm16ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { com2pm16ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.10 com2pm16ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { com2pm16ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.11 com2pm16ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { com2pm16ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.12 com2pm16ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { com2pm16ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.13 com2pm16ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { com2pm16ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.14 com2pm16ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { com2pm16ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.15 com2pm16ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { com2pm16ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.16 com2pm16ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { com2pm16ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.17 com2pm16ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { com2pm16ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.2.1.18 com2pm16ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { com2pm16ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3 com2pm16IOinfo OBJECT IDENTIFIER ::= { com2pm16 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.1 com2pm16DITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.1.1 com2pm16DIEntry OBJECT-TYPE SYNTAX Com2pm16DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16DIIndex } ::= { com2pm16DITable 1 } Com2pm16DIEntry ::= SEQUENCE { com2pm16DIIndex Integer32, com2pm16DIName OCTET STRING, com2pm16DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.1.1.1 com2pm16DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { com2pm16DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.1.1.2 com2pm16DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { com2pm16DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.1.1.3 com2pm16DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { com2pm16DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.2 com2pm16DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.2.1 com2pm16DOEntry OBJECT-TYPE SYNTAX Com2pm16DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16DOIndex } ::= { com2pm16DOTable 1 } Com2pm16DOEntry ::= SEQUENCE { com2pm16DOIndex Integer32, com2pm16DOName OCTET STRING, com2pm16DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.2.1.1 com2pm16DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { com2pm16DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.2.1.2 com2pm16DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { com2pm16DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.2.1.3 com2pm16DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { com2pm16DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.3 com2pm16AITable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.3.1 com2pm16AIEntry OBJECT-TYPE SYNTAX Com2pm16AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16AIIndex } ::= { com2pm16AITable 1 } Com2pm16AIEntry ::= SEQUENCE { com2pm16AIIndex Integer32, com2pm16AIName OCTET STRING, com2pm16AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.3.1.1 com2pm16AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { com2pm16AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.3.1.2 com2pm16AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { com2pm16AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.3.1.3 com2pm16AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { com2pm16AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.4 com2pm16AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.4.1 com2pm16AOEntry OBJECT-TYPE SYNTAX Com2pm16AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16AOIndex } ::= { com2pm16AOTable 1 } Com2pm16AOEntry ::= SEQUENCE { com2pm16AOIndex Integer32, com2pm16AOName OCTET STRING, com2pm16AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.4.1.1 com2pm16AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { com2pm16AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.4.1.2 com2pm16AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { com2pm16AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.3.4.1.3 com2pm16AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { com2pm16AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.4 com2pm16HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2pm16HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2pm16 4 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.4.1 com2pm16HarmonicEntry OBJECT-TYPE SYNTAX Com2pm16HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2pm16HarmonicSubmeterIndex } ::= { com2pm16HarmonicTable 1 } Com2pm16HarmonicEntry ::= SEQUENCE { com2pm16HarmonicSubmeterIndex Integer32, com2pm16HarmonicSelector Integer32, com2pm16HarmonicVTHD Opaque, com2pm16HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.4.1.1 com2pm16HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { com2pm16HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.4.1.2 com2pm16HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { com2pm16HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.4.1.3 com2pm16HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { com2pm16HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.2.16.4.1.4 com2pm16HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { com2pm16HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3 lanpm OBJECT IDENTIFIER ::= { powerMeterInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1 lanpm1 OBJECT IDENTIFIER ::= { lanpm 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1 lanpm1BasicInfo OBJECT IDENTIFIER ::= { lanpm1 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.1 lanpm1Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm1BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.2 lanpm1Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm1BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.3 lanpm1ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm1BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.4 lanpm1Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm1BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.5 lanpm1PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.5.1 lanpm1PtEntry OBJECT-TYPE SYNTAX Lanpm1PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1PtIndex } ::= { lanpm1PtTable 1 } Lanpm1PtEntry ::= SEQUENCE { lanpm1PtIndex Integer32, lanpm1PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.5.1.1 lanpm1PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm1PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.5.1.2 lanpm1PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm1PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.6 lanpm1CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.6.1 lanpm1CtEntry OBJECT-TYPE SYNTAX Lanpm1CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1CtIndex } ::= { lanpm1CtTable 1 } Lanpm1CtEntry ::= SEQUENCE { lanpm1CtIndex Integer32, lanpm1CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.6.1.1 lanpm1CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm1CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.6.1.2 lanpm1CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm1CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.9 lanpm1DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm1BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.10 lanpm1DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm1BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.11 lanpm1AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm1BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.12 lanpm1AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm1BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.13 lanpm1PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm1BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.14 lanpm1RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm1BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.15 lanpm1ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm1BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.1.16 lanpm1StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm1BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2 lanpm1ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1 lanpm1ChEntry OBJECT-TYPE SYNTAX Lanpm1ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1ChSubmeterIndex } ::= { lanpm1ChTable 1 } Lanpm1ChEntry ::= SEQUENCE { lanpm1ChSubmeterIndex Integer32, lanpm1ChName OCTET STRING, lanpm1ChVoltage Opaque, lanpm1ChCurrent Opaque, lanpm1ChKW Opaque, lanpm1ChKvar Opaque, lanpm1ChKVA Opaque, lanpm1ChPF Opaque, lanpm1ChKWh Opaque, lanpm1ChKvarh Opaque, lanpm1ChKVAh Opaque, lanpm1ChActualDemand Opaque, lanpm1ChForecastDemand Opaque, lanpm1ChMaxDemandH Opaque, lanpm1ChMaxDemandD Opaque, lanpm1ChMaxDemandM Opaque, lanpm1ChElectricityD Opaque, lanpm1ChElectricityM Opaque, lanpm1ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.0 lanpm1ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm1ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.1 lanpm1ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm1ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.2 lanpm1ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm1ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.3 lanpm1ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm1ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.4 lanpm1ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm1ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.5 lanpm1ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm1ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.6 lanpm1ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm1ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.7 lanpm1ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm1ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.8 lanpm1ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm1ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.9 lanpm1ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm1ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.10 lanpm1ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm1ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.11 lanpm1ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm1ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.12 lanpm1ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm1ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.13 lanpm1ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm1ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.14 lanpm1ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm1ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.15 lanpm1ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm1ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.16 lanpm1ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm1ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.17 lanpm1ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm1ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.2.1.18 lanpm1ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm1ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3 lanpm1IOinfo OBJECT IDENTIFIER ::= { lanpm1 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.1 lanpm1DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.1.1 lanpm1DIEntry OBJECT-TYPE SYNTAX Lanpm1DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1DIIndex } ::= { lanpm1DITable 1 } Lanpm1DIEntry ::= SEQUENCE { lanpm1DIIndex Integer32, lanpm1DIName OCTET STRING, lanpm1DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.1.1.1 lanpm1DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm1DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.1.1.2 lanpm1DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm1DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.1.1.3 lanpm1DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm1DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.2 lanpm1DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.2.1 lanpm1DOEntry OBJECT-TYPE SYNTAX Lanpm1DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1DOIndex } ::= { lanpm1DOTable 1 } Lanpm1DOEntry ::= SEQUENCE { lanpm1DOIndex Integer32, lanpm1DOName OCTET STRING, lanpm1DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.2.1.1 lanpm1DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm1DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.2.1.2 lanpm1DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm1DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.2.1.3 lanpm1DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm1DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.3 lanpm1AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.3.1 lanpm1AIEntry OBJECT-TYPE SYNTAX Lanpm1AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1AIIndex } ::= { lanpm1AITable 1 } Lanpm1AIEntry ::= SEQUENCE { lanpm1AIIndex Integer32, lanpm1AIName OCTET STRING, lanpm1AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.3.1.1 lanpm1AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm1AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.3.1.2 lanpm1AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm1AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.3.1.3 lanpm1AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm1AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.4 lanpm1AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.4.1 lanpm1AOEntry OBJECT-TYPE SYNTAX Lanpm1AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1AOIndex } ::= { lanpm1AOTable 1 } Lanpm1AOEntry ::= SEQUENCE { lanpm1AOIndex Integer32, lanpm1AOName OCTET STRING, lanpm1AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.4.1.1 lanpm1AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm1AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.4.1.2 lanpm1AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm1AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.3.4.1.3 lanpm1AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm1AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.4 lanpm1HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm1HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm1 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.4.1 lanpm1HarmonicEntry OBJECT-TYPE SYNTAX Lanpm1HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm1HarmonicSubmeterIndex } ::= { lanpm1HarmonicTable 1 } Lanpm1HarmonicEntry ::= SEQUENCE { lanpm1HarmonicSubmeterIndex Integer32, lanpm1HarmonicSelector Integer32, lanpm1HarmonicVTHD Opaque, lanpm1HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.4.1.1 lanpm1HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm1HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.4.1.2 lanpm1HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm1HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.4.1.3 lanpm1HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm1HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.1.4.1.4 lanpm1HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm1HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2 lanpm2 OBJECT IDENTIFIER ::= { lanpm 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1 lanpm2BasicInfo OBJECT IDENTIFIER ::= { lanpm2 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.1 lanpm2Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm2BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.2 lanpm2Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm2BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.3 lanpm2ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm2BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.4 lanpm2Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm2BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.5 lanpm2PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.5.1 lanpm2PtEntry OBJECT-TYPE SYNTAX Lanpm2PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2PtIndex } ::= { lanpm2PtTable 1 } Lanpm2PtEntry ::= SEQUENCE { lanpm2PtIndex Integer32, lanpm2PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.5.1.1 lanpm2PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm2PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.5.1.2 lanpm2PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm2PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.6 lanpm2CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.6.1 lanpm2CtEntry OBJECT-TYPE SYNTAX Lanpm2CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2CtIndex } ::= { lanpm2CtTable 1 } Lanpm2CtEntry ::= SEQUENCE { lanpm2CtIndex Integer32, lanpm2CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.6.1.1 lanpm2CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm2CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.6.1.2 lanpm2CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm2CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.9 lanpm2DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm2BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.10 lanpm2DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm2BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.11 lanpm2AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm2BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.12 lanpm2AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm2BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.13 lanpm2PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm2BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.14 lanpm2RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm2BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.15 lanpm2ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm2BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.1.16 lanpm2StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm2BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2 lanpm2ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1 lanpm2ChEntry OBJECT-TYPE SYNTAX Lanpm2ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2ChSubmeterIndex } ::= { lanpm2ChTable 1 } Lanpm2ChEntry ::= SEQUENCE { lanpm2ChSubmeterIndex Integer32, lanpm2ChName OCTET STRING, lanpm2ChVoltage Opaque, lanpm2ChCurrent Opaque, lanpm2ChKW Opaque, lanpm2ChKvar Opaque, lanpm2ChKVA Opaque, lanpm2ChPF Opaque, lanpm2ChKWh Opaque, lanpm2ChKvarh Opaque, lanpm2ChKVAh Opaque, lanpm2ChActualDemand Opaque, lanpm2ChForecastDemand Opaque, lanpm2ChMaxDemandH Opaque, lanpm2ChMaxDemandD Opaque, lanpm2ChMaxDemandM Opaque, lanpm2ChElectricityD Opaque, lanpm2ChElectricityM Opaque, lanpm2ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.0 lanpm2ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm2ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.1 lanpm2ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm2ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.2 lanpm2ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm2ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.3 lanpm2ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm2ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.4 lanpm2ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm2ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.5 lanpm2ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm2ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.6 lanpm2ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm2ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.7 lanpm2ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm2ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.8 lanpm2ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm2ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.9 lanpm2ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm2ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.10 lanpm2ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm2ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.11 lanpm2ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm2ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.12 lanpm2ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm2ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.13 lanpm2ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm2ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.14 lanpm2ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm2ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.15 lanpm2ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm2ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.16 lanpm2ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm2ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.17 lanpm2ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm2ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.2.1.18 lanpm2ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm2ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3 lanpm2IOinfo OBJECT IDENTIFIER ::= { lanpm2 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.1 lanpm2DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.1.1 lanpm2DIEntry OBJECT-TYPE SYNTAX Lanpm2DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2DIIndex } ::= { lanpm2DITable 1 } Lanpm2DIEntry ::= SEQUENCE { lanpm2DIIndex Integer32, lanpm2DIName OCTET STRING, lanpm2DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.1.1.1 lanpm2DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm2DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.1.1.2 lanpm2DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm2DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.1.1.3 lanpm2DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm2DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.2 lanpm2DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.2.1 lanpm2DOEntry OBJECT-TYPE SYNTAX Lanpm2DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2DOIndex } ::= { lanpm2DOTable 1 } Lanpm2DOEntry ::= SEQUENCE { lanpm2DOIndex Integer32, lanpm2DOName OCTET STRING, lanpm2DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.2.1.1 lanpm2DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm2DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.2.1.2 lanpm2DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm2DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.2.1.3 lanpm2DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm2DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.3 lanpm2AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.3.1 lanpm2AIEntry OBJECT-TYPE SYNTAX Lanpm2AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2AIIndex } ::= { lanpm2AITable 1 } Lanpm2AIEntry ::= SEQUENCE { lanpm2AIIndex Integer32, lanpm2AIName OCTET STRING, lanpm2AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.3.1.1 lanpm2AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm2AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.3.1.2 lanpm2AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm2AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.3.1.3 lanpm2AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm2AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.4 lanpm2AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.4.1 lanpm2AOEntry OBJECT-TYPE SYNTAX Lanpm2AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2AOIndex } ::= { lanpm2AOTable 1 } Lanpm2AOEntry ::= SEQUENCE { lanpm2AOIndex Integer32, lanpm2AOName OCTET STRING, lanpm2AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.4.1.1 lanpm2AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm2AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.4.1.2 lanpm2AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm2AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.3.4.1.3 lanpm2AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm2AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.4 lanpm2HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm2HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm2 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.4.1 lanpm2HarmonicEntry OBJECT-TYPE SYNTAX Lanpm2HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm2HarmonicSubmeterIndex } ::= { lanpm2HarmonicTable 1 } Lanpm2HarmonicEntry ::= SEQUENCE { lanpm2HarmonicSubmeterIndex Integer32, lanpm2HarmonicSelector Integer32, lanpm2HarmonicVTHD Opaque, lanpm2HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.4.1.1 lanpm2HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm2HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.4.1.2 lanpm2HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm2HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.4.1.3 lanpm2HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm2HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.2.4.1.4 lanpm2HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm2HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3 lanpm3 OBJECT IDENTIFIER ::= { lanpm 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1 lanpm3BasicInfo OBJECT IDENTIFIER ::= { lanpm3 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.1 lanpm3Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm3BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.2 lanpm3Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm3BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.3 lanpm3ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm3BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.4 lanpm3Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm3BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.5 lanpm3PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.5.1 lanpm3PtEntry OBJECT-TYPE SYNTAX Lanpm3PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3PtIndex } ::= { lanpm3PtTable 1 } Lanpm3PtEntry ::= SEQUENCE { lanpm3PtIndex Integer32, lanpm3PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.5.1.1 lanpm3PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm3PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.5.1.2 lanpm3PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm3PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.6 lanpm3CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.6.1 lanpm3CtEntry OBJECT-TYPE SYNTAX Lanpm3CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3CtIndex } ::= { lanpm3CtTable 1 } Lanpm3CtEntry ::= SEQUENCE { lanpm3CtIndex Integer32, lanpm3CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.6.1.1 lanpm3CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm3CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.6.1.2 lanpm3CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm3CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.9 lanpm3DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm3BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.10 lanpm3DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm3BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.11 lanpm3AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm3BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.12 lanpm3AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm3BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.13 lanpm3PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm3BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.14 lanpm3RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm3BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.15 lanpm3ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm3BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.1.16 lanpm3StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm3BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2 lanpm3ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1 lanpm3ChEntry OBJECT-TYPE SYNTAX Lanpm3ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3ChSubmeterIndex } ::= { lanpm3ChTable 1 } Lanpm3ChEntry ::= SEQUENCE { lanpm3ChSubmeterIndex Integer32, lanpm3ChName OCTET STRING, lanpm3ChVoltage Opaque, lanpm3ChCurrent Opaque, lanpm3ChKW Opaque, lanpm3ChKvar Opaque, lanpm3ChKVA Opaque, lanpm3ChPF Opaque, lanpm3ChKWh Opaque, lanpm3ChKvarh Opaque, lanpm3ChKVAh Opaque, lanpm3ChActualDemand Opaque, lanpm3ChForecastDemand Opaque, lanpm3ChMaxDemandH Opaque, lanpm3ChMaxDemandD Opaque, lanpm3ChMaxDemandM Opaque, lanpm3ChElectricityD Opaque, lanpm3ChElectricityM Opaque, lanpm3ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.0 lanpm3ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm3ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.1 lanpm3ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm3ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.2 lanpm3ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm3ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.3 lanpm3ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm3ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.4 lanpm3ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm3ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.5 lanpm3ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm3ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.6 lanpm3ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm3ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.7 lanpm3ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm3ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.8 lanpm3ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm3ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.9 lanpm3ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm3ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.10 lanpm3ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm3ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.11 lanpm3ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm3ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.12 lanpm3ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm3ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.13 lanpm3ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm3ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.14 lanpm3ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm3ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.15 lanpm3ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm3ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.16 lanpm3ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm3ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.17 lanpm3ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm3ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.2.1.18 lanpm3ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm3ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3 lanpm3IOinfo OBJECT IDENTIFIER ::= { lanpm3 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.1 lanpm3DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.1.1 lanpm3DIEntry OBJECT-TYPE SYNTAX Lanpm3DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3DIIndex } ::= { lanpm3DITable 1 } Lanpm3DIEntry ::= SEQUENCE { lanpm3DIIndex Integer32, lanpm3DIName OCTET STRING, lanpm3DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.1.1.1 lanpm3DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm3DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.1.1.2 lanpm3DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm3DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.1.1.3 lanpm3DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm3DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.2 lanpm3DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.2.1 lanpm3DOEntry OBJECT-TYPE SYNTAX Lanpm3DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3DOIndex } ::= { lanpm3DOTable 1 } Lanpm3DOEntry ::= SEQUENCE { lanpm3DOIndex Integer32, lanpm3DOName OCTET STRING, lanpm3DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.2.1.1 lanpm3DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm3DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.2.1.2 lanpm3DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm3DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.2.1.3 lanpm3DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm3DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.3 lanpm3AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.3.1 lanpm3AIEntry OBJECT-TYPE SYNTAX Lanpm3AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3AIIndex } ::= { lanpm3AITable 1 } Lanpm3AIEntry ::= SEQUENCE { lanpm3AIIndex Integer32, lanpm3AIName OCTET STRING, lanpm3AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.3.1.1 lanpm3AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm3AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.3.1.2 lanpm3AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm3AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.3.1.3 lanpm3AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm3AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.4 lanpm3AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.4.1 lanpm3AOEntry OBJECT-TYPE SYNTAX Lanpm3AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3AOIndex } ::= { lanpm3AOTable 1 } Lanpm3AOEntry ::= SEQUENCE { lanpm3AOIndex Integer32, lanpm3AOName OCTET STRING, lanpm3AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.4.1.1 lanpm3AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm3AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.4.1.2 lanpm3AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm3AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.3.4.1.3 lanpm3AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm3AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.4 lanpm3HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm3HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm3 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.4.1 lanpm3HarmonicEntry OBJECT-TYPE SYNTAX Lanpm3HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm3HarmonicSubmeterIndex } ::= { lanpm3HarmonicTable 1 } Lanpm3HarmonicEntry ::= SEQUENCE { lanpm3HarmonicSubmeterIndex Integer32, lanpm3HarmonicSelector Integer32, lanpm3HarmonicVTHD Opaque, lanpm3HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.4.1.1 lanpm3HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm3HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.4.1.2 lanpm3HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm3HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.4.1.3 lanpm3HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm3HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.3.4.1.4 lanpm3HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm3HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4 lanpm4 OBJECT IDENTIFIER ::= { lanpm 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1 lanpm4BasicInfo OBJECT IDENTIFIER ::= { lanpm4 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.1 lanpm4Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm4BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.2 lanpm4Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm4BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.3 lanpm4ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm4BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.4 lanpm4Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm4BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.5 lanpm4PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.5.1 lanpm4PtEntry OBJECT-TYPE SYNTAX Lanpm4PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4PtIndex } ::= { lanpm4PtTable 1 } Lanpm4PtEntry ::= SEQUENCE { lanpm4PtIndex Integer32, lanpm4PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.5.1.1 lanpm4PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm4PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.5.1.2 lanpm4PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm4PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.6 lanpm4CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.6.1 lanpm4CtEntry OBJECT-TYPE SYNTAX Lanpm4CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4CtIndex } ::= { lanpm4CtTable 1 } Lanpm4CtEntry ::= SEQUENCE { lanpm4CtIndex Integer32, lanpm4CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.6.1.1 lanpm4CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm4CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.6.1.2 lanpm4CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm4CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.9 lanpm4DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm4BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.10 lanpm4DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm4BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.11 lanpm4AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm4BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.12 lanpm4AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm4BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.13 lanpm4PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm4BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.14 lanpm4RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm4BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.15 lanpm4ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm4BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.1.16 lanpm4StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm4BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2 lanpm4ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1 lanpm4ChEntry OBJECT-TYPE SYNTAX Lanpm4ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4ChSubmeterIndex } ::= { lanpm4ChTable 1 } Lanpm4ChEntry ::= SEQUENCE { lanpm4ChSubmeterIndex Integer32, lanpm4ChName OCTET STRING, lanpm4ChVoltage Opaque, lanpm4ChCurrent Opaque, lanpm4ChKW Opaque, lanpm4ChKvar Opaque, lanpm4ChKVA Opaque, lanpm4ChPF Opaque, lanpm4ChKWh Opaque, lanpm4ChKvarh Opaque, lanpm4ChKVAh Opaque, lanpm4ChActualDemand Opaque, lanpm4ChForecastDemand Opaque, lanpm4ChMaxDemandH Opaque, lanpm4ChMaxDemandD Opaque, lanpm4ChMaxDemandM Opaque, lanpm4ChElectricityD Opaque, lanpm4ChElectricityM Opaque, lanpm4ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.0 lanpm4ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm4ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.1 lanpm4ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm4ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.2 lanpm4ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm4ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.3 lanpm4ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm4ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.4 lanpm4ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm4ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.5 lanpm4ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm4ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.6 lanpm4ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm4ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.7 lanpm4ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm4ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.8 lanpm4ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm4ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.9 lanpm4ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm4ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.10 lanpm4ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm4ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.11 lanpm4ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm4ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.12 lanpm4ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm4ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.13 lanpm4ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm4ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.14 lanpm4ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm4ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.15 lanpm4ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm4ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.16 lanpm4ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm4ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.17 lanpm4ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm4ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.2.1.18 lanpm4ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm4ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3 lanpm4IOinfo OBJECT IDENTIFIER ::= { lanpm4 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.1 lanpm4DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.1.1 lanpm4DIEntry OBJECT-TYPE SYNTAX Lanpm4DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4DIIndex } ::= { lanpm4DITable 1 } Lanpm4DIEntry ::= SEQUENCE { lanpm4DIIndex Integer32, lanpm4DIName OCTET STRING, lanpm4DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.1.1.1 lanpm4DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm4DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.1.1.2 lanpm4DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm4DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.1.1.3 lanpm4DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm4DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.2 lanpm4DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.2.1 lanpm4DOEntry OBJECT-TYPE SYNTAX Lanpm4DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4DOIndex } ::= { lanpm4DOTable 1 } Lanpm4DOEntry ::= SEQUENCE { lanpm4DOIndex Integer32, lanpm4DOName OCTET STRING, lanpm4DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.2.1.1 lanpm4DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm4DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.2.1.2 lanpm4DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm4DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.2.1.3 lanpm4DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm4DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.3 lanpm4AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.3.1 lanpm4AIEntry OBJECT-TYPE SYNTAX Lanpm4AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4AIIndex } ::= { lanpm4AITable 1 } Lanpm4AIEntry ::= SEQUENCE { lanpm4AIIndex Integer32, lanpm4AIName OCTET STRING, lanpm4AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.3.1.1 lanpm4AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm4AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.3.1.2 lanpm4AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm4AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.3.1.3 lanpm4AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm4AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.4 lanpm4AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.4.1 lanpm4AOEntry OBJECT-TYPE SYNTAX Lanpm4AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4AOIndex } ::= { lanpm4AOTable 1 } Lanpm4AOEntry ::= SEQUENCE { lanpm4AOIndex Integer32, lanpm4AOName OCTET STRING, lanpm4AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.4.1.1 lanpm4AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm4AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.4.1.2 lanpm4AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm4AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.3.4.1.3 lanpm4AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm4AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.4 lanpm4HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm4HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm4 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.4.1 lanpm4HarmonicEntry OBJECT-TYPE SYNTAX Lanpm4HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm4HarmonicSubmeterIndex } ::= { lanpm4HarmonicTable 1 } Lanpm4HarmonicEntry ::= SEQUENCE { lanpm4HarmonicSubmeterIndex Integer32, lanpm4HarmonicSelector Integer32, lanpm4HarmonicVTHD Opaque, lanpm4HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.4.1.1 lanpm4HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm4HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.4.1.2 lanpm4HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm4HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.4.1.3 lanpm4HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm4HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.4.4.1.4 lanpm4HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm4HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5 lanpm5 OBJECT IDENTIFIER ::= { lanpm 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1 lanpm5BasicInfo OBJECT IDENTIFIER ::= { lanpm5 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.1 lanpm5Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm5BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.2 lanpm5Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm5BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.3 lanpm5ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm5BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.4 lanpm5Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm5BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.5 lanpm5PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.5.1 lanpm5PtEntry OBJECT-TYPE SYNTAX Lanpm5PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5PtIndex } ::= { lanpm5PtTable 1 } Lanpm5PtEntry ::= SEQUENCE { lanpm5PtIndex Integer32, lanpm5PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.5.1.1 lanpm5PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm5PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.5.1.2 lanpm5PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm5PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.6 lanpm5CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.6.1 lanpm5CtEntry OBJECT-TYPE SYNTAX Lanpm5CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5CtIndex } ::= { lanpm5CtTable 1 } Lanpm5CtEntry ::= SEQUENCE { lanpm5CtIndex Integer32, lanpm5CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.6.1.1 lanpm5CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm5CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.6.1.2 lanpm5CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm5CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.9 lanpm5DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm5BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.10 lanpm5DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm5BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.11 lanpm5AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm5BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.12 lanpm5AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm5BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.13 lanpm5PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm5BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.14 lanpm5RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm5BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.15 lanpm5ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm5BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.1.16 lanpm5StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm5BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2 lanpm5ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1 lanpm5ChEntry OBJECT-TYPE SYNTAX Lanpm5ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5ChSubmeterIndex } ::= { lanpm5ChTable 1 } Lanpm5ChEntry ::= SEQUENCE { lanpm5ChSubmeterIndex Integer32, lanpm5ChName OCTET STRING, lanpm5ChVoltage Opaque, lanpm5ChCurrent Opaque, lanpm5ChKW Opaque, lanpm5ChKvar Opaque, lanpm5ChKVA Opaque, lanpm5ChPF Opaque, lanpm5ChKWh Opaque, lanpm5ChKvarh Opaque, lanpm5ChKVAh Opaque, lanpm5ChActualDemand Opaque, lanpm5ChForecastDemand Opaque, lanpm5ChMaxDemandH Opaque, lanpm5ChMaxDemandD Opaque, lanpm5ChMaxDemandM Opaque, lanpm5ChElectricityD Opaque, lanpm5ChElectricityM Opaque, lanpm5ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.0 lanpm5ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm5ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.1 lanpm5ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm5ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.2 lanpm5ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm5ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.3 lanpm5ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm5ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.4 lanpm5ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm5ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.5 lanpm5ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm5ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.6 lanpm5ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm5ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.7 lanpm5ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm5ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.8 lanpm5ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm5ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.9 lanpm5ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm5ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.10 lanpm5ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm5ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.11 lanpm5ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm5ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.12 lanpm5ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm5ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.13 lanpm5ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm5ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.14 lanpm5ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm5ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.15 lanpm5ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm5ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.16 lanpm5ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm5ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.17 lanpm5ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm5ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.2.1.18 lanpm5ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm5ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3 lanpm5IOinfo OBJECT IDENTIFIER ::= { lanpm5 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.1 lanpm5DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.1.1 lanpm5DIEntry OBJECT-TYPE SYNTAX Lanpm5DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5DIIndex } ::= { lanpm5DITable 1 } Lanpm5DIEntry ::= SEQUENCE { lanpm5DIIndex Integer32, lanpm5DIName OCTET STRING, lanpm5DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.1.1.1 lanpm5DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm5DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.1.1.2 lanpm5DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm5DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.1.1.3 lanpm5DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm5DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.2 lanpm5DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.2.1 lanpm5DOEntry OBJECT-TYPE SYNTAX Lanpm5DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5DOIndex } ::= { lanpm5DOTable 1 } Lanpm5DOEntry ::= SEQUENCE { lanpm5DOIndex Integer32, lanpm5DOName OCTET STRING, lanpm5DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.2.1.1 lanpm5DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm5DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.2.1.2 lanpm5DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm5DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.2.1.3 lanpm5DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm5DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.3 lanpm5AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.3.1 lanpm5AIEntry OBJECT-TYPE SYNTAX Lanpm5AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5AIIndex } ::= { lanpm5AITable 1 } Lanpm5AIEntry ::= SEQUENCE { lanpm5AIIndex Integer32, lanpm5AIName OCTET STRING, lanpm5AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.3.1.1 lanpm5AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm5AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.3.1.2 lanpm5AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm5AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.3.1.3 lanpm5AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm5AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.4 lanpm5AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.4.1 lanpm5AOEntry OBJECT-TYPE SYNTAX Lanpm5AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5AOIndex } ::= { lanpm5AOTable 1 } Lanpm5AOEntry ::= SEQUENCE { lanpm5AOIndex Integer32, lanpm5AOName OCTET STRING, lanpm5AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.4.1.1 lanpm5AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm5AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.4.1.2 lanpm5AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm5AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.3.4.1.3 lanpm5AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm5AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.4 lanpm5HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm5HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm5 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.4.1 lanpm5HarmonicEntry OBJECT-TYPE SYNTAX Lanpm5HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm5HarmonicSubmeterIndex } ::= { lanpm5HarmonicTable 1 } Lanpm5HarmonicEntry ::= SEQUENCE { lanpm5HarmonicSubmeterIndex Integer32, lanpm5HarmonicSelector Integer32, lanpm5HarmonicVTHD Opaque, lanpm5HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.4.1.1 lanpm5HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm5HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.4.1.2 lanpm5HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm5HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.4.1.3 lanpm5HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm5HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.5.4.1.4 lanpm5HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm5HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6 lanpm6 OBJECT IDENTIFIER ::= { lanpm 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1 lanpm6BasicInfo OBJECT IDENTIFIER ::= { lanpm6 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.1 lanpm6Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm6BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.2 lanpm6Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm6BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.3 lanpm6ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm6BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.4 lanpm6Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm6BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.5 lanpm6PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.5.1 lanpm6PtEntry OBJECT-TYPE SYNTAX Lanpm6PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6PtIndex } ::= { lanpm6PtTable 1 } Lanpm6PtEntry ::= SEQUENCE { lanpm6PtIndex Integer32, lanpm6PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.5.1.1 lanpm6PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm6PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.5.1.2 lanpm6PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm6PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.6 lanpm6CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.6.1 lanpm6CtEntry OBJECT-TYPE SYNTAX Lanpm6CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6CtIndex } ::= { lanpm6CtTable 1 } Lanpm6CtEntry ::= SEQUENCE { lanpm6CtIndex Integer32, lanpm6CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.6.1.1 lanpm6CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm6CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.6.1.2 lanpm6CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm6CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.9 lanpm6DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm6BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.10 lanpm6DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm6BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.11 lanpm6AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm6BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.12 lanpm6AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm6BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.13 lanpm6PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm6BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.14 lanpm6RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm6BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.15 lanpm6ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm6BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.1.16 lanpm6StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm6BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2 lanpm6ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1 lanpm6ChEntry OBJECT-TYPE SYNTAX Lanpm6ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6ChSubmeterIndex } ::= { lanpm6ChTable 1 } Lanpm6ChEntry ::= SEQUENCE { lanpm6ChSubmeterIndex Integer32, lanpm6ChName OCTET STRING, lanpm6ChVoltage Opaque, lanpm6ChCurrent Opaque, lanpm6ChKW Opaque, lanpm6ChKvar Opaque, lanpm6ChKVA Opaque, lanpm6ChPF Opaque, lanpm6ChKWh Opaque, lanpm6ChKvarh Opaque, lanpm6ChKVAh Opaque, lanpm6ChActualDemand Opaque, lanpm6ChForecastDemand Opaque, lanpm6ChMaxDemandH Opaque, lanpm6ChMaxDemandD Opaque, lanpm6ChMaxDemandM Opaque, lanpm6ChElectricityD Opaque, lanpm6ChElectricityM Opaque, lanpm6ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.0 lanpm6ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm6ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.1 lanpm6ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm6ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.2 lanpm6ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm6ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.3 lanpm6ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm6ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.4 lanpm6ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm6ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.5 lanpm6ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm6ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.6 lanpm6ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm6ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.7 lanpm6ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm6ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.8 lanpm6ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm6ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.9 lanpm6ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm6ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.10 lanpm6ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm6ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.11 lanpm6ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm6ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.12 lanpm6ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm6ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.13 lanpm6ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm6ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.14 lanpm6ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm6ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.15 lanpm6ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm6ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.16 lanpm6ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm6ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.17 lanpm6ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm6ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.2.1.18 lanpm6ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm6ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3 lanpm6IOinfo OBJECT IDENTIFIER ::= { lanpm6 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.1 lanpm6DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.1.1 lanpm6DIEntry OBJECT-TYPE SYNTAX Lanpm6DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6DIIndex } ::= { lanpm6DITable 1 } Lanpm6DIEntry ::= SEQUENCE { lanpm6DIIndex Integer32, lanpm6DIName OCTET STRING, lanpm6DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.1.1.1 lanpm6DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm6DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.1.1.2 lanpm6DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm6DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.1.1.3 lanpm6DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm6DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.2 lanpm6DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.2.1 lanpm6DOEntry OBJECT-TYPE SYNTAX Lanpm6DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6DOIndex } ::= { lanpm6DOTable 1 } Lanpm6DOEntry ::= SEQUENCE { lanpm6DOIndex Integer32, lanpm6DOName OCTET STRING, lanpm6DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.2.1.1 lanpm6DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm6DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.2.1.2 lanpm6DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm6DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.2.1.3 lanpm6DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm6DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.3 lanpm6AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.3.1 lanpm6AIEntry OBJECT-TYPE SYNTAX Lanpm6AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6AIIndex } ::= { lanpm6AITable 1 } Lanpm6AIEntry ::= SEQUENCE { lanpm6AIIndex Integer32, lanpm6AIName OCTET STRING, lanpm6AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.3.1.1 lanpm6AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm6AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.3.1.2 lanpm6AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm6AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.3.1.3 lanpm6AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm6AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.4 lanpm6AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.4.1 lanpm6AOEntry OBJECT-TYPE SYNTAX Lanpm6AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6AOIndex } ::= { lanpm6AOTable 1 } Lanpm6AOEntry ::= SEQUENCE { lanpm6AOIndex Integer32, lanpm6AOName OCTET STRING, lanpm6AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.4.1.1 lanpm6AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm6AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.4.1.2 lanpm6AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm6AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.3.4.1.3 lanpm6AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm6AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.4 lanpm6HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm6HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm6 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.4.1 lanpm6HarmonicEntry OBJECT-TYPE SYNTAX Lanpm6HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm6HarmonicSubmeterIndex } ::= { lanpm6HarmonicTable 1 } Lanpm6HarmonicEntry ::= SEQUENCE { lanpm6HarmonicSubmeterIndex Integer32, lanpm6HarmonicSelector Integer32, lanpm6HarmonicVTHD Opaque, lanpm6HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.4.1.1 lanpm6HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm6HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.4.1.2 lanpm6HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm6HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.4.1.3 lanpm6HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm6HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.6.4.1.4 lanpm6HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm6HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7 lanpm7 OBJECT IDENTIFIER ::= { lanpm 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1 lanpm7BasicInfo OBJECT IDENTIFIER ::= { lanpm7 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.1 lanpm7Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm7BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.2 lanpm7Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm7BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.3 lanpm7ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm7BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.4 lanpm7Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm7BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.5 lanpm7PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.5.1 lanpm7PtEntry OBJECT-TYPE SYNTAX Lanpm7PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7PtIndex } ::= { lanpm7PtTable 1 } Lanpm7PtEntry ::= SEQUENCE { lanpm7PtIndex Integer32, lanpm7PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.5.1.1 lanpm7PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm7PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.5.1.2 lanpm7PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm7PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.6 lanpm7CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.6.1 lanpm7CtEntry OBJECT-TYPE SYNTAX Lanpm7CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7CtIndex } ::= { lanpm7CtTable 1 } Lanpm7CtEntry ::= SEQUENCE { lanpm7CtIndex Integer32, lanpm7CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.6.1.1 lanpm7CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm7CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.6.1.2 lanpm7CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm7CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.9 lanpm7DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm7BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.10 lanpm7DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm7BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.11 lanpm7AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm7BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.12 lanpm7AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm7BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.13 lanpm7PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm7BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.14 lanpm7RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm7BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.15 lanpm7ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm7BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.1.16 lanpm7StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm7BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2 lanpm7ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1 lanpm7ChEntry OBJECT-TYPE SYNTAX Lanpm7ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7ChSubmeterIndex } ::= { lanpm7ChTable 1 } Lanpm7ChEntry ::= SEQUENCE { lanpm7ChSubmeterIndex Integer32, lanpm7ChName OCTET STRING, lanpm7ChVoltage Opaque, lanpm7ChCurrent Opaque, lanpm7ChKW Opaque, lanpm7ChKvar Opaque, lanpm7ChKVA Opaque, lanpm7ChPF Opaque, lanpm7ChKWh Opaque, lanpm7ChKvarh Opaque, lanpm7ChKVAh Opaque, lanpm7ChActualDemand Opaque, lanpm7ChForecastDemand Opaque, lanpm7ChMaxDemandH Opaque, lanpm7ChMaxDemandD Opaque, lanpm7ChMaxDemandM Opaque, lanpm7ChElectricityD Opaque, lanpm7ChElectricityM Opaque, lanpm7ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.0 lanpm7ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm7ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.1 lanpm7ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm7ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.2 lanpm7ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm7ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.3 lanpm7ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm7ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.4 lanpm7ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm7ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.5 lanpm7ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm7ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.6 lanpm7ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm7ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.7 lanpm7ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm7ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.8 lanpm7ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm7ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.9 lanpm7ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm7ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.10 lanpm7ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm7ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.11 lanpm7ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm7ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.12 lanpm7ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm7ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.13 lanpm7ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm7ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.14 lanpm7ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm7ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.15 lanpm7ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm7ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.16 lanpm7ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm7ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.17 lanpm7ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm7ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.2.1.18 lanpm7ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm7ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3 lanpm7IOinfo OBJECT IDENTIFIER ::= { lanpm7 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.1 lanpm7DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.1.1 lanpm7DIEntry OBJECT-TYPE SYNTAX Lanpm7DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7DIIndex } ::= { lanpm7DITable 1 } Lanpm7DIEntry ::= SEQUENCE { lanpm7DIIndex Integer32, lanpm7DIName OCTET STRING, lanpm7DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.1.1.1 lanpm7DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm7DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.1.1.2 lanpm7DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm7DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.1.1.3 lanpm7DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm7DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.2 lanpm7DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.2.1 lanpm7DOEntry OBJECT-TYPE SYNTAX Lanpm7DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7DOIndex } ::= { lanpm7DOTable 1 } Lanpm7DOEntry ::= SEQUENCE { lanpm7DOIndex Integer32, lanpm7DOName OCTET STRING, lanpm7DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.2.1.1 lanpm7DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm7DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.2.1.2 lanpm7DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm7DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.2.1.3 lanpm7DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm7DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.3 lanpm7AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.3.1 lanpm7AIEntry OBJECT-TYPE SYNTAX Lanpm7AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7AIIndex } ::= { lanpm7AITable 1 } Lanpm7AIEntry ::= SEQUENCE { lanpm7AIIndex Integer32, lanpm7AIName OCTET STRING, lanpm7AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.3.1.1 lanpm7AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm7AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.3.1.2 lanpm7AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm7AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.3.1.3 lanpm7AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm7AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.4 lanpm7AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.4.1 lanpm7AOEntry OBJECT-TYPE SYNTAX Lanpm7AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7AOIndex } ::= { lanpm7AOTable 1 } Lanpm7AOEntry ::= SEQUENCE { lanpm7AOIndex Integer32, lanpm7AOName OCTET STRING, lanpm7AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.4.1.1 lanpm7AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm7AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.4.1.2 lanpm7AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm7AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.3.4.1.3 lanpm7AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm7AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.4 lanpm7HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm7HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm7 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.4.1 lanpm7HarmonicEntry OBJECT-TYPE SYNTAX Lanpm7HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm7HarmonicSubmeterIndex } ::= { lanpm7HarmonicTable 1 } Lanpm7HarmonicEntry ::= SEQUENCE { lanpm7HarmonicSubmeterIndex Integer32, lanpm7HarmonicSelector Integer32, lanpm7HarmonicVTHD Opaque, lanpm7HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.4.1.1 lanpm7HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm7HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.4.1.2 lanpm7HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm7HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.4.1.3 lanpm7HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm7HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.7.4.1.4 lanpm7HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm7HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8 lanpm8 OBJECT IDENTIFIER ::= { lanpm 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1 lanpm8BasicInfo OBJECT IDENTIFIER ::= { lanpm8 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.1 lanpm8Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm8BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.2 lanpm8Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm8BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.3 lanpm8ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm8BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.4 lanpm8Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm8BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.5 lanpm8PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.5.1 lanpm8PtEntry OBJECT-TYPE SYNTAX Lanpm8PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8PtIndex } ::= { lanpm8PtTable 1 } Lanpm8PtEntry ::= SEQUENCE { lanpm8PtIndex Integer32, lanpm8PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.5.1.1 lanpm8PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm8PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.5.1.2 lanpm8PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm8PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.6 lanpm8CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.6.1 lanpm8CtEntry OBJECT-TYPE SYNTAX Lanpm8CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8CtIndex } ::= { lanpm8CtTable 1 } Lanpm8CtEntry ::= SEQUENCE { lanpm8CtIndex Integer32, lanpm8CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.6.1.1 lanpm8CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm8CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.6.1.2 lanpm8CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm8CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.9 lanpm8DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm8BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.10 lanpm8DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm8BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.11 lanpm8AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm8BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.12 lanpm8AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm8BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.13 lanpm8PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm8BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.14 lanpm8RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm8BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.15 lanpm8ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm8BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.1.16 lanpm8StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm8BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2 lanpm8ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1 lanpm8ChEntry OBJECT-TYPE SYNTAX Lanpm8ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8ChSubmeterIndex } ::= { lanpm8ChTable 1 } Lanpm8ChEntry ::= SEQUENCE { lanpm8ChSubmeterIndex Integer32, lanpm8ChName OCTET STRING, lanpm8ChVoltage Opaque, lanpm8ChCurrent Opaque, lanpm8ChKW Opaque, lanpm8ChKvar Opaque, lanpm8ChKVA Opaque, lanpm8ChPF Opaque, lanpm8ChKWh Opaque, lanpm8ChKvarh Opaque, lanpm8ChKVAh Opaque, lanpm8ChActualDemand Opaque, lanpm8ChForecastDemand Opaque, lanpm8ChMaxDemandH Opaque, lanpm8ChMaxDemandD Opaque, lanpm8ChMaxDemandM Opaque, lanpm8ChElectricityD Opaque, lanpm8ChElectricityM Opaque, lanpm8ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.0 lanpm8ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm8ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.1 lanpm8ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm8ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.2 lanpm8ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm8ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.3 lanpm8ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm8ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.4 lanpm8ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm8ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.5 lanpm8ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm8ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.6 lanpm8ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm8ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.7 lanpm8ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm8ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.8 lanpm8ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm8ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.9 lanpm8ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm8ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.10 lanpm8ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm8ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.11 lanpm8ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm8ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.12 lanpm8ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm8ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.13 lanpm8ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm8ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.14 lanpm8ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm8ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.15 lanpm8ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm8ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.16 lanpm8ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm8ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.17 lanpm8ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm8ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.2.1.18 lanpm8ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm8ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3 lanpm8IOinfo OBJECT IDENTIFIER ::= { lanpm8 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.1 lanpm8DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.1.1 lanpm8DIEntry OBJECT-TYPE SYNTAX Lanpm8DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8DIIndex } ::= { lanpm8DITable 1 } Lanpm8DIEntry ::= SEQUENCE { lanpm8DIIndex Integer32, lanpm8DIName OCTET STRING, lanpm8DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.1.1.1 lanpm8DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm8DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.1.1.2 lanpm8DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm8DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.1.1.3 lanpm8DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm8DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.2 lanpm8DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.2.1 lanpm8DOEntry OBJECT-TYPE SYNTAX Lanpm8DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8DOIndex } ::= { lanpm8DOTable 1 } Lanpm8DOEntry ::= SEQUENCE { lanpm8DOIndex Integer32, lanpm8DOName OCTET STRING, lanpm8DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.2.1.1 lanpm8DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm8DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.2.1.2 lanpm8DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm8DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.2.1.3 lanpm8DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm8DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.3 lanpm8AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.3.1 lanpm8AIEntry OBJECT-TYPE SYNTAX Lanpm8AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8AIIndex } ::= { lanpm8AITable 1 } Lanpm8AIEntry ::= SEQUENCE { lanpm8AIIndex Integer32, lanpm8AIName OCTET STRING, lanpm8AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.3.1.1 lanpm8AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm8AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.3.1.2 lanpm8AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm8AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.3.1.3 lanpm8AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm8AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.4 lanpm8AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.4.1 lanpm8AOEntry OBJECT-TYPE SYNTAX Lanpm8AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8AOIndex } ::= { lanpm8AOTable 1 } Lanpm8AOEntry ::= SEQUENCE { lanpm8AOIndex Integer32, lanpm8AOName OCTET STRING, lanpm8AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.4.1.1 lanpm8AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm8AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.4.1.2 lanpm8AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm8AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.3.4.1.3 lanpm8AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm8AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.4 lanpm8HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm8HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm8 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.4.1 lanpm8HarmonicEntry OBJECT-TYPE SYNTAX Lanpm8HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm8HarmonicSubmeterIndex } ::= { lanpm8HarmonicTable 1 } Lanpm8HarmonicEntry ::= SEQUENCE { lanpm8HarmonicSubmeterIndex Integer32, lanpm8HarmonicSelector Integer32, lanpm8HarmonicVTHD Opaque, lanpm8HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.4.1.1 lanpm8HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm8HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.4.1.2 lanpm8HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm8HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.4.1.3 lanpm8HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm8HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.8.4.1.4 lanpm8HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm8HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9 lanpm9 OBJECT IDENTIFIER ::= { lanpm 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1 lanpm9BasicInfo OBJECT IDENTIFIER ::= { lanpm9 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.1 lanpm9Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm9BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.2 lanpm9Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm9BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.3 lanpm9ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm9BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.4 lanpm9Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm9BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.5 lanpm9PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.5.1 lanpm9PtEntry OBJECT-TYPE SYNTAX Lanpm9PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9PtIndex } ::= { lanpm9PtTable 1 } Lanpm9PtEntry ::= SEQUENCE { lanpm9PtIndex Integer32, lanpm9PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.5.1.1 lanpm9PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm9PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.5.1.2 lanpm9PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm9PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.6 lanpm9CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.6.1 lanpm9CtEntry OBJECT-TYPE SYNTAX Lanpm9CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9CtIndex } ::= { lanpm9CtTable 1 } Lanpm9CtEntry ::= SEQUENCE { lanpm9CtIndex Integer32, lanpm9CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.6.1.1 lanpm9CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm9CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.6.1.2 lanpm9CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm9CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.9 lanpm9DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm9BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.10 lanpm9DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm9BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.11 lanpm9AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm9BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.12 lanpm9AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm9BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.13 lanpm9PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm9BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.14 lanpm9RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm9BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.15 lanpm9ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm9BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.1.16 lanpm9StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm9BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2 lanpm9ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1 lanpm9ChEntry OBJECT-TYPE SYNTAX Lanpm9ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9ChSubmeterIndex } ::= { lanpm9ChTable 1 } Lanpm9ChEntry ::= SEQUENCE { lanpm9ChSubmeterIndex Integer32, lanpm9ChName OCTET STRING, lanpm9ChVoltage Opaque, lanpm9ChCurrent Opaque, lanpm9ChKW Opaque, lanpm9ChKvar Opaque, lanpm9ChKVA Opaque, lanpm9ChPF Opaque, lanpm9ChKWh Opaque, lanpm9ChKvarh Opaque, lanpm9ChKVAh Opaque, lanpm9ChActualDemand Opaque, lanpm9ChForecastDemand Opaque, lanpm9ChMaxDemandH Opaque, lanpm9ChMaxDemandD Opaque, lanpm9ChMaxDemandM Opaque, lanpm9ChElectricityD Opaque, lanpm9ChElectricityM Opaque, lanpm9ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.0 lanpm9ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm9ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.1 lanpm9ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm9ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.2 lanpm9ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm9ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.3 lanpm9ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm9ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.4 lanpm9ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm9ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.5 lanpm9ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm9ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.6 lanpm9ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm9ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.7 lanpm9ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm9ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.8 lanpm9ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm9ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.9 lanpm9ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm9ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.10 lanpm9ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm9ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.11 lanpm9ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm9ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.12 lanpm9ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm9ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.13 lanpm9ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm9ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.14 lanpm9ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm9ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.15 lanpm9ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm9ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.16 lanpm9ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm9ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.17 lanpm9ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm9ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.2.1.18 lanpm9ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm9ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3 lanpm9IOinfo OBJECT IDENTIFIER ::= { lanpm9 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.1 lanpm9DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.1.1 lanpm9DIEntry OBJECT-TYPE SYNTAX Lanpm9DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9DIIndex } ::= { lanpm9DITable 1 } Lanpm9DIEntry ::= SEQUENCE { lanpm9DIIndex Integer32, lanpm9DIName OCTET STRING, lanpm9DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.1.1.1 lanpm9DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm9DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.1.1.2 lanpm9DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm9DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.1.1.3 lanpm9DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm9DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.2 lanpm9DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.2.1 lanpm9DOEntry OBJECT-TYPE SYNTAX Lanpm9DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9DOIndex } ::= { lanpm9DOTable 1 } Lanpm9DOEntry ::= SEQUENCE { lanpm9DOIndex Integer32, lanpm9DOName OCTET STRING, lanpm9DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.2.1.1 lanpm9DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm9DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.2.1.2 lanpm9DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm9DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.2.1.3 lanpm9DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm9DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.3 lanpm9AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.3.1 lanpm9AIEntry OBJECT-TYPE SYNTAX Lanpm9AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9AIIndex } ::= { lanpm9AITable 1 } Lanpm9AIEntry ::= SEQUENCE { lanpm9AIIndex Integer32, lanpm9AIName OCTET STRING, lanpm9AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.3.1.1 lanpm9AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm9AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.3.1.2 lanpm9AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm9AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.3.1.3 lanpm9AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm9AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.4 lanpm9AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.4.1 lanpm9AOEntry OBJECT-TYPE SYNTAX Lanpm9AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9AOIndex } ::= { lanpm9AOTable 1 } Lanpm9AOEntry ::= SEQUENCE { lanpm9AOIndex Integer32, lanpm9AOName OCTET STRING, lanpm9AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.4.1.1 lanpm9AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm9AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.4.1.2 lanpm9AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm9AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.3.4.1.3 lanpm9AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm9AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.4 lanpm9HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm9HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm9 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.4.1 lanpm9HarmonicEntry OBJECT-TYPE SYNTAX Lanpm9HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm9HarmonicSubmeterIndex } ::= { lanpm9HarmonicTable 1 } Lanpm9HarmonicEntry ::= SEQUENCE { lanpm9HarmonicSubmeterIndex Integer32, lanpm9HarmonicSelector Integer32, lanpm9HarmonicVTHD Opaque, lanpm9HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.4.1.1 lanpm9HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm9HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.4.1.2 lanpm9HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm9HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.4.1.3 lanpm9HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm9HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.9.4.1.4 lanpm9HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm9HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10 lanpm10 OBJECT IDENTIFIER ::= { lanpm 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1 lanpm10BasicInfo OBJECT IDENTIFIER ::= { lanpm10 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.1 lanpm10Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm10BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.2 lanpm10Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm10BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.3 lanpm10ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm10BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.4 lanpm10Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm10BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.5 lanpm10PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.5.1 lanpm10PtEntry OBJECT-TYPE SYNTAX Lanpm10PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10PtIndex } ::= { lanpm10PtTable 1 } Lanpm10PtEntry ::= SEQUENCE { lanpm10PtIndex Integer32, lanpm10PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.5.1.1 lanpm10PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm10PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.5.1.2 lanpm10PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm10PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.6 lanpm10CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.6.1 lanpm10CtEntry OBJECT-TYPE SYNTAX Lanpm10CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10CtIndex } ::= { lanpm10CtTable 1 } Lanpm10CtEntry ::= SEQUENCE { lanpm10CtIndex Integer32, lanpm10CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.6.1.1 lanpm10CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm10CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.6.1.2 lanpm10CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm10CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.9 lanpm10DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm10BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.10 lanpm10DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm10BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.11 lanpm10AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm10BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.12 lanpm10AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm10BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.13 lanpm10PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm10BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.14 lanpm10RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm10BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.15 lanpm10ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm10BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.1.16 lanpm10StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm10BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2 lanpm10ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1 lanpm10ChEntry OBJECT-TYPE SYNTAX Lanpm10ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10ChSubmeterIndex } ::= { lanpm10ChTable 1 } Lanpm10ChEntry ::= SEQUENCE { lanpm10ChSubmeterIndex Integer32, lanpm10ChName OCTET STRING, lanpm10ChVoltage Opaque, lanpm10ChCurrent Opaque, lanpm10ChKW Opaque, lanpm10ChKvar Opaque, lanpm10ChKVA Opaque, lanpm10ChPF Opaque, lanpm10ChKWh Opaque, lanpm10ChKvarh Opaque, lanpm10ChKVAh Opaque, lanpm10ChActualDemand Opaque, lanpm10ChForecastDemand Opaque, lanpm10ChMaxDemandH Opaque, lanpm10ChMaxDemandD Opaque, lanpm10ChMaxDemandM Opaque, lanpm10ChElectricityD Opaque, lanpm10ChElectricityM Opaque, lanpm10ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.0 lanpm10ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm10ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.1 lanpm10ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm10ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.2 lanpm10ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm10ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.3 lanpm10ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm10ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.4 lanpm10ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm10ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.5 lanpm10ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm10ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.6 lanpm10ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm10ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.7 lanpm10ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm10ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.8 lanpm10ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm10ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.9 lanpm10ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm10ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.10 lanpm10ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm10ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.11 lanpm10ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm10ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.12 lanpm10ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm10ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.13 lanpm10ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm10ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.14 lanpm10ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm10ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.15 lanpm10ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm10ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.16 lanpm10ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm10ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.17 lanpm10ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm10ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.2.1.18 lanpm10ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm10ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3 lanpm10IOinfo OBJECT IDENTIFIER ::= { lanpm10 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.1 lanpm10DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.1.1 lanpm10DIEntry OBJECT-TYPE SYNTAX Lanpm10DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10DIIndex } ::= { lanpm10DITable 1 } Lanpm10DIEntry ::= SEQUENCE { lanpm10DIIndex Integer32, lanpm10DIName OCTET STRING, lanpm10DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.1.1.1 lanpm10DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm10DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.1.1.2 lanpm10DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm10DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.1.1.3 lanpm10DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm10DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.2 lanpm10DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.2.1 lanpm10DOEntry OBJECT-TYPE SYNTAX Lanpm10DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10DOIndex } ::= { lanpm10DOTable 1 } Lanpm10DOEntry ::= SEQUENCE { lanpm10DOIndex Integer32, lanpm10DOName OCTET STRING, lanpm10DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.2.1.1 lanpm10DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm10DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.2.1.2 lanpm10DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm10DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.2.1.3 lanpm10DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm10DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.3 lanpm10AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.3.1 lanpm10AIEntry OBJECT-TYPE SYNTAX Lanpm10AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10AIIndex } ::= { lanpm10AITable 1 } Lanpm10AIEntry ::= SEQUENCE { lanpm10AIIndex Integer32, lanpm10AIName OCTET STRING, lanpm10AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.3.1.1 lanpm10AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm10AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.3.1.2 lanpm10AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm10AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.3.1.3 lanpm10AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm10AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.4 lanpm10AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.4.1 lanpm10AOEntry OBJECT-TYPE SYNTAX Lanpm10AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10AOIndex } ::= { lanpm10AOTable 1 } Lanpm10AOEntry ::= SEQUENCE { lanpm10AOIndex Integer32, lanpm10AOName OCTET STRING, lanpm10AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.4.1.1 lanpm10AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm10AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.4.1.2 lanpm10AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm10AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.3.4.1.3 lanpm10AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm10AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.4 lanpm10HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm10HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm10 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.4.1 lanpm10HarmonicEntry OBJECT-TYPE SYNTAX Lanpm10HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm10HarmonicSubmeterIndex } ::= { lanpm10HarmonicTable 1 } Lanpm10HarmonicEntry ::= SEQUENCE { lanpm10HarmonicSubmeterIndex Integer32, lanpm10HarmonicSelector Integer32, lanpm10HarmonicVTHD Opaque, lanpm10HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.4.1.1 lanpm10HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm10HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.4.1.2 lanpm10HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm10HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.4.1.3 lanpm10HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm10HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.10.4.1.4 lanpm10HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm10HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11 lanpm11 OBJECT IDENTIFIER ::= { lanpm 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1 lanpm11BasicInfo OBJECT IDENTIFIER ::= { lanpm11 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.1 lanpm11Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm11BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.2 lanpm11Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm11BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.3 lanpm11ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm11BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.4 lanpm11Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm11BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.5 lanpm11PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.5.1 lanpm11PtEntry OBJECT-TYPE SYNTAX Lanpm11PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11PtIndex } ::= { lanpm11PtTable 1 } Lanpm11PtEntry ::= SEQUENCE { lanpm11PtIndex Integer32, lanpm11PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.5.1.1 lanpm11PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm11PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.5.1.2 lanpm11PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm11PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.6 lanpm11CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.6.1 lanpm11CtEntry OBJECT-TYPE SYNTAX Lanpm11CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11CtIndex } ::= { lanpm11CtTable 1 } Lanpm11CtEntry ::= SEQUENCE { lanpm11CtIndex Integer32, lanpm11CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.6.1.1 lanpm11CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm11CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.6.1.2 lanpm11CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm11CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.9 lanpm11DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm11BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.10 lanpm11DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm11BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.11 lanpm11AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm11BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.12 lanpm11AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm11BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.13 lanpm11PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm11BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.14 lanpm11RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm11BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.15 lanpm11ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm11BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.1.16 lanpm11StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm11BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2 lanpm11ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1 lanpm11ChEntry OBJECT-TYPE SYNTAX Lanpm11ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11ChSubmeterIndex } ::= { lanpm11ChTable 1 } Lanpm11ChEntry ::= SEQUENCE { lanpm11ChSubmeterIndex Integer32, lanpm11ChName OCTET STRING, lanpm11ChVoltage Opaque, lanpm11ChCurrent Opaque, lanpm11ChKW Opaque, lanpm11ChKvar Opaque, lanpm11ChKVA Opaque, lanpm11ChPF Opaque, lanpm11ChKWh Opaque, lanpm11ChKvarh Opaque, lanpm11ChKVAh Opaque, lanpm11ChActualDemand Opaque, lanpm11ChForecastDemand Opaque, lanpm11ChMaxDemandH Opaque, lanpm11ChMaxDemandD Opaque, lanpm11ChMaxDemandM Opaque, lanpm11ChElectricityD Opaque, lanpm11ChElectricityM Opaque, lanpm11ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.0 lanpm11ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm11ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.1 lanpm11ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm11ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.2 lanpm11ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm11ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.3 lanpm11ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm11ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.4 lanpm11ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm11ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.5 lanpm11ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm11ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.6 lanpm11ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm11ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.7 lanpm11ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm11ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.8 lanpm11ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm11ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.9 lanpm11ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm11ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.10 lanpm11ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm11ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.11 lanpm11ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm11ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.12 lanpm11ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm11ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.13 lanpm11ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm11ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.14 lanpm11ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm11ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.15 lanpm11ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm11ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.16 lanpm11ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm11ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.17 lanpm11ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm11ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.2.1.18 lanpm11ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm11ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3 lanpm11IOinfo OBJECT IDENTIFIER ::= { lanpm11 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.1 lanpm11DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.1.1 lanpm11DIEntry OBJECT-TYPE SYNTAX Lanpm11DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11DIIndex } ::= { lanpm11DITable 1 } Lanpm11DIEntry ::= SEQUENCE { lanpm11DIIndex Integer32, lanpm11DIName OCTET STRING, lanpm11DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.1.1.1 lanpm11DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm11DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.1.1.2 lanpm11DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm11DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.1.1.3 lanpm11DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm11DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.2 lanpm11DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.2.1 lanpm11DOEntry OBJECT-TYPE SYNTAX Lanpm11DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11DOIndex } ::= { lanpm11DOTable 1 } Lanpm11DOEntry ::= SEQUENCE { lanpm11DOIndex Integer32, lanpm11DOName OCTET STRING, lanpm11DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.2.1.1 lanpm11DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm11DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.2.1.2 lanpm11DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm11DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.2.1.3 lanpm11DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm11DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.3 lanpm11AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.3.1 lanpm11AIEntry OBJECT-TYPE SYNTAX Lanpm11AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11AIIndex } ::= { lanpm11AITable 1 } Lanpm11AIEntry ::= SEQUENCE { lanpm11AIIndex Integer32, lanpm11AIName OCTET STRING, lanpm11AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.3.1.1 lanpm11AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm11AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.3.1.2 lanpm11AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm11AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.3.1.3 lanpm11AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm11AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.4 lanpm11AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.4.1 lanpm11AOEntry OBJECT-TYPE SYNTAX Lanpm11AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11AOIndex } ::= { lanpm11AOTable 1 } Lanpm11AOEntry ::= SEQUENCE { lanpm11AOIndex Integer32, lanpm11AOName OCTET STRING, lanpm11AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.4.1.1 lanpm11AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm11AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.4.1.2 lanpm11AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm11AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.3.4.1.3 lanpm11AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm11AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.4 lanpm11HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm11HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm11 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.4.1 lanpm11HarmonicEntry OBJECT-TYPE SYNTAX Lanpm11HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm11HarmonicSubmeterIndex } ::= { lanpm11HarmonicTable 1 } Lanpm11HarmonicEntry ::= SEQUENCE { lanpm11HarmonicSubmeterIndex Integer32, lanpm11HarmonicSelector Integer32, lanpm11HarmonicVTHD Opaque, lanpm11HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.4.1.1 lanpm11HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm11HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.4.1.2 lanpm11HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm11HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.4.1.3 lanpm11HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm11HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.11.4.1.4 lanpm11HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm11HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12 lanpm12 OBJECT IDENTIFIER ::= { lanpm 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1 lanpm12BasicInfo OBJECT IDENTIFIER ::= { lanpm12 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.1 lanpm12Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm12BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.2 lanpm12Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm12BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.3 lanpm12ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm12BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.4 lanpm12Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm12BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.5 lanpm12PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.5.1 lanpm12PtEntry OBJECT-TYPE SYNTAX Lanpm12PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12PtIndex } ::= { lanpm12PtTable 1 } Lanpm12PtEntry ::= SEQUENCE { lanpm12PtIndex Integer32, lanpm12PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.5.1.1 lanpm12PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm12PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.5.1.2 lanpm12PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm12PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.6 lanpm12CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.6.1 lanpm12CtEntry OBJECT-TYPE SYNTAX Lanpm12CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12CtIndex } ::= { lanpm12CtTable 1 } Lanpm12CtEntry ::= SEQUENCE { lanpm12CtIndex Integer32, lanpm12CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.6.1.1 lanpm12CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm12CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.6.1.2 lanpm12CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm12CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.9 lanpm12DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm12BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.10 lanpm12DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm12BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.11 lanpm12AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm12BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.12 lanpm12AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm12BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.13 lanpm12PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm12BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.14 lanpm12RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm12BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.15 lanpm12ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm12BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.1.16 lanpm12StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm12BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2 lanpm12ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1 lanpm12ChEntry OBJECT-TYPE SYNTAX Lanpm12ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12ChSubmeterIndex } ::= { lanpm12ChTable 1 } Lanpm12ChEntry ::= SEQUENCE { lanpm12ChSubmeterIndex Integer32, lanpm12ChName OCTET STRING, lanpm12ChVoltage Opaque, lanpm12ChCurrent Opaque, lanpm12ChKW Opaque, lanpm12ChKvar Opaque, lanpm12ChKVA Opaque, lanpm12ChPF Opaque, lanpm12ChKWh Opaque, lanpm12ChKvarh Opaque, lanpm12ChKVAh Opaque, lanpm12ChActualDemand Opaque, lanpm12ChForecastDemand Opaque, lanpm12ChMaxDemandH Opaque, lanpm12ChMaxDemandD Opaque, lanpm12ChMaxDemandM Opaque, lanpm12ChElectricityD Opaque, lanpm12ChElectricityM Opaque, lanpm12ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.0 lanpm12ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm12ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.1 lanpm12ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm12ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.2 lanpm12ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm12ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.3 lanpm12ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm12ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.4 lanpm12ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm12ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.5 lanpm12ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm12ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.6 lanpm12ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm12ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.7 lanpm12ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm12ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.8 lanpm12ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm12ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.9 lanpm12ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm12ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.10 lanpm12ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm12ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.11 lanpm12ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm12ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.12 lanpm12ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm12ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.13 lanpm12ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm12ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.14 lanpm12ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm12ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.15 lanpm12ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm12ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.16 lanpm12ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm12ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.17 lanpm12ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm12ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.2.1.18 lanpm12ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm12ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3 lanpm12IOinfo OBJECT IDENTIFIER ::= { lanpm12 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.1 lanpm12DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.1.1 lanpm12DIEntry OBJECT-TYPE SYNTAX Lanpm12DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12DIIndex } ::= { lanpm12DITable 1 } Lanpm12DIEntry ::= SEQUENCE { lanpm12DIIndex Integer32, lanpm12DIName OCTET STRING, lanpm12DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.1.1.1 lanpm12DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm12DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.1.1.2 lanpm12DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm12DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.1.1.3 lanpm12DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm12DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.2 lanpm12DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.2.1 lanpm12DOEntry OBJECT-TYPE SYNTAX Lanpm12DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12DOIndex } ::= { lanpm12DOTable 1 } Lanpm12DOEntry ::= SEQUENCE { lanpm12DOIndex Integer32, lanpm12DOName OCTET STRING, lanpm12DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.2.1.1 lanpm12DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm12DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.2.1.2 lanpm12DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm12DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.2.1.3 lanpm12DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm12DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.3 lanpm12AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.3.1 lanpm12AIEntry OBJECT-TYPE SYNTAX Lanpm12AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12AIIndex } ::= { lanpm12AITable 1 } Lanpm12AIEntry ::= SEQUENCE { lanpm12AIIndex Integer32, lanpm12AIName OCTET STRING, lanpm12AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.3.1.1 lanpm12AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm12AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.3.1.2 lanpm12AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm12AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.3.1.3 lanpm12AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm12AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.4 lanpm12AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.4.1 lanpm12AOEntry OBJECT-TYPE SYNTAX Lanpm12AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12AOIndex } ::= { lanpm12AOTable 1 } Lanpm12AOEntry ::= SEQUENCE { lanpm12AOIndex Integer32, lanpm12AOName OCTET STRING, lanpm12AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.4.1.1 lanpm12AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm12AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.4.1.2 lanpm12AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm12AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.3.4.1.3 lanpm12AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm12AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.4 lanpm12HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm12HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm12 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.4.1 lanpm12HarmonicEntry OBJECT-TYPE SYNTAX Lanpm12HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm12HarmonicSubmeterIndex } ::= { lanpm12HarmonicTable 1 } Lanpm12HarmonicEntry ::= SEQUENCE { lanpm12HarmonicSubmeterIndex Integer32, lanpm12HarmonicSelector Integer32, lanpm12HarmonicVTHD Opaque, lanpm12HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.4.1.1 lanpm12HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm12HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.4.1.2 lanpm12HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm12HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.4.1.3 lanpm12HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm12HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.12.4.1.4 lanpm12HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm12HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13 lanpm13 OBJECT IDENTIFIER ::= { lanpm 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1 lanpm13BasicInfo OBJECT IDENTIFIER ::= { lanpm13 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.1 lanpm13Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm13BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.2 lanpm13Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm13BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.3 lanpm13ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm13BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.4 lanpm13Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm13BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.5 lanpm13PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.5.1 lanpm13PtEntry OBJECT-TYPE SYNTAX Lanpm13PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13PtIndex } ::= { lanpm13PtTable 1 } Lanpm13PtEntry ::= SEQUENCE { lanpm13PtIndex Integer32, lanpm13PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.5.1.1 lanpm13PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm13PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.5.1.2 lanpm13PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm13PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.6 lanpm13CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.6.1 lanpm13CtEntry OBJECT-TYPE SYNTAX Lanpm13CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13CtIndex } ::= { lanpm13CtTable 1 } Lanpm13CtEntry ::= SEQUENCE { lanpm13CtIndex Integer32, lanpm13CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.6.1.1 lanpm13CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm13CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.6.1.2 lanpm13CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm13CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.9 lanpm13DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm13BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.10 lanpm13DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm13BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.11 lanpm13AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm13BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.12 lanpm13AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm13BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.13 lanpm13PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm13BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.14 lanpm13RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm13BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.15 lanpm13ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm13BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.1.16 lanpm13StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm13BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2 lanpm13ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1 lanpm13ChEntry OBJECT-TYPE SYNTAX Lanpm13ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13ChSubmeterIndex } ::= { lanpm13ChTable 1 } Lanpm13ChEntry ::= SEQUENCE { lanpm13ChSubmeterIndex Integer32, lanpm13ChName OCTET STRING, lanpm13ChVoltage Opaque, lanpm13ChCurrent Opaque, lanpm13ChKW Opaque, lanpm13ChKvar Opaque, lanpm13ChKVA Opaque, lanpm13ChPF Opaque, lanpm13ChKWh Opaque, lanpm13ChKvarh Opaque, lanpm13ChKVAh Opaque, lanpm13ChActualDemand Opaque, lanpm13ChForecastDemand Opaque, lanpm13ChMaxDemandH Opaque, lanpm13ChMaxDemandD Opaque, lanpm13ChMaxDemandM Opaque, lanpm13ChElectricityD Opaque, lanpm13ChElectricityM Opaque, lanpm13ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.0 lanpm13ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm13ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.1 lanpm13ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm13ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.2 lanpm13ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm13ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.3 lanpm13ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm13ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.4 lanpm13ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm13ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.5 lanpm13ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm13ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.6 lanpm13ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm13ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.7 lanpm13ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm13ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.8 lanpm13ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm13ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.9 lanpm13ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm13ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.10 lanpm13ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm13ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.11 lanpm13ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm13ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.12 lanpm13ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm13ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.13 lanpm13ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm13ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.14 lanpm13ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm13ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.15 lanpm13ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm13ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.16 lanpm13ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm13ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.17 lanpm13ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm13ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.2.1.18 lanpm13ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm13ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3 lanpm13IOinfo OBJECT IDENTIFIER ::= { lanpm13 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.1 lanpm13DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.1.1 lanpm13DIEntry OBJECT-TYPE SYNTAX Lanpm13DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13DIIndex } ::= { lanpm13DITable 1 } Lanpm13DIEntry ::= SEQUENCE { lanpm13DIIndex Integer32, lanpm13DIName OCTET STRING, lanpm13DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.1.1.1 lanpm13DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm13DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.1.1.2 lanpm13DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm13DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.1.1.3 lanpm13DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm13DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.2 lanpm13DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.2.1 lanpm13DOEntry OBJECT-TYPE SYNTAX Lanpm13DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13DOIndex } ::= { lanpm13DOTable 1 } Lanpm13DOEntry ::= SEQUENCE { lanpm13DOIndex Integer32, lanpm13DOName OCTET STRING, lanpm13DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.2.1.1 lanpm13DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm13DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.2.1.2 lanpm13DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm13DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.2.1.3 lanpm13DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm13DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.3 lanpm13AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.3.1 lanpm13AIEntry OBJECT-TYPE SYNTAX Lanpm13AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13AIIndex } ::= { lanpm13AITable 1 } Lanpm13AIEntry ::= SEQUENCE { lanpm13AIIndex Integer32, lanpm13AIName OCTET STRING, lanpm13AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.3.1.1 lanpm13AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm13AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.3.1.2 lanpm13AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm13AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.3.1.3 lanpm13AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm13AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.4 lanpm13AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.4.1 lanpm13AOEntry OBJECT-TYPE SYNTAX Lanpm13AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13AOIndex } ::= { lanpm13AOTable 1 } Lanpm13AOEntry ::= SEQUENCE { lanpm13AOIndex Integer32, lanpm13AOName OCTET STRING, lanpm13AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.4.1.1 lanpm13AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm13AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.4.1.2 lanpm13AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm13AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.3.4.1.3 lanpm13AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm13AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.4 lanpm13HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm13HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm13 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.4.1 lanpm13HarmonicEntry OBJECT-TYPE SYNTAX Lanpm13HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm13HarmonicSubmeterIndex } ::= { lanpm13HarmonicTable 1 } Lanpm13HarmonicEntry ::= SEQUENCE { lanpm13HarmonicSubmeterIndex Integer32, lanpm13HarmonicSelector Integer32, lanpm13HarmonicVTHD Opaque, lanpm13HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.4.1.1 lanpm13HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm13HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.4.1.2 lanpm13HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm13HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.4.1.3 lanpm13HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm13HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.13.4.1.4 lanpm13HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm13HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14 lanpm14 OBJECT IDENTIFIER ::= { lanpm 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1 lanpm14BasicInfo OBJECT IDENTIFIER ::= { lanpm14 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.1 lanpm14Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm14BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.2 lanpm14Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm14BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.3 lanpm14ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm14BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.4 lanpm14Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm14BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.5 lanpm14PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.5.1 lanpm14PtEntry OBJECT-TYPE SYNTAX Lanpm14PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14PtIndex } ::= { lanpm14PtTable 1 } Lanpm14PtEntry ::= SEQUENCE { lanpm14PtIndex Integer32, lanpm14PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.5.1.1 lanpm14PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm14PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.5.1.2 lanpm14PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm14PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.6 lanpm14CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.6.1 lanpm14CtEntry OBJECT-TYPE SYNTAX Lanpm14CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14CtIndex } ::= { lanpm14CtTable 1 } Lanpm14CtEntry ::= SEQUENCE { lanpm14CtIndex Integer32, lanpm14CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.6.1.1 lanpm14CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm14CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.6.1.2 lanpm14CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm14CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.9 lanpm14DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm14BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.10 lanpm14DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm14BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.11 lanpm14AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm14BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.12 lanpm14AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm14BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.13 lanpm14PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm14BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.14 lanpm14RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm14BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.15 lanpm14ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm14BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.1.16 lanpm14StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm14BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2 lanpm14ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1 lanpm14ChEntry OBJECT-TYPE SYNTAX Lanpm14ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14ChSubmeterIndex } ::= { lanpm14ChTable 1 } Lanpm14ChEntry ::= SEQUENCE { lanpm14ChSubmeterIndex Integer32, lanpm14ChName OCTET STRING, lanpm14ChVoltage Opaque, lanpm14ChCurrent Opaque, lanpm14ChKW Opaque, lanpm14ChKvar Opaque, lanpm14ChKVA Opaque, lanpm14ChPF Opaque, lanpm14ChKWh Opaque, lanpm14ChKvarh Opaque, lanpm14ChKVAh Opaque, lanpm14ChActualDemand Opaque, lanpm14ChForecastDemand Opaque, lanpm14ChMaxDemandH Opaque, lanpm14ChMaxDemandD Opaque, lanpm14ChMaxDemandM Opaque, lanpm14ChElectricityD Opaque, lanpm14ChElectricityM Opaque, lanpm14ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.0 lanpm14ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm14ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.1 lanpm14ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm14ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.2 lanpm14ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm14ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.3 lanpm14ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm14ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.4 lanpm14ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm14ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.5 lanpm14ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm14ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.6 lanpm14ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm14ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.7 lanpm14ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm14ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.8 lanpm14ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm14ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.9 lanpm14ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm14ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.10 lanpm14ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm14ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.11 lanpm14ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm14ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.12 lanpm14ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm14ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.13 lanpm14ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm14ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.14 lanpm14ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm14ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.15 lanpm14ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm14ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.16 lanpm14ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm14ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.17 lanpm14ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm14ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.2.1.18 lanpm14ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm14ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3 lanpm14IOinfo OBJECT IDENTIFIER ::= { lanpm14 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.1 lanpm14DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.1.1 lanpm14DIEntry OBJECT-TYPE SYNTAX Lanpm14DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14DIIndex } ::= { lanpm14DITable 1 } Lanpm14DIEntry ::= SEQUENCE { lanpm14DIIndex Integer32, lanpm14DIName OCTET STRING, lanpm14DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.1.1.1 lanpm14DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm14DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.1.1.2 lanpm14DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm14DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.1.1.3 lanpm14DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm14DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.2 lanpm14DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.2.1 lanpm14DOEntry OBJECT-TYPE SYNTAX Lanpm14DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14DOIndex } ::= { lanpm14DOTable 1 } Lanpm14DOEntry ::= SEQUENCE { lanpm14DOIndex Integer32, lanpm14DOName OCTET STRING, lanpm14DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.2.1.1 lanpm14DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm14DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.2.1.2 lanpm14DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm14DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.2.1.3 lanpm14DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm14DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.3 lanpm14AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.3.1 lanpm14AIEntry OBJECT-TYPE SYNTAX Lanpm14AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14AIIndex } ::= { lanpm14AITable 1 } Lanpm14AIEntry ::= SEQUENCE { lanpm14AIIndex Integer32, lanpm14AIName OCTET STRING, lanpm14AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.3.1.1 lanpm14AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm14AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.3.1.2 lanpm14AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm14AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.3.1.3 lanpm14AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm14AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.4 lanpm14AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.4.1 lanpm14AOEntry OBJECT-TYPE SYNTAX Lanpm14AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14AOIndex } ::= { lanpm14AOTable 1 } Lanpm14AOEntry ::= SEQUENCE { lanpm14AOIndex Integer32, lanpm14AOName OCTET STRING, lanpm14AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.4.1.1 lanpm14AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm14AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.4.1.2 lanpm14AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm14AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.3.4.1.3 lanpm14AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm14AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.4 lanpm14HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm14HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm14 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.4.1 lanpm14HarmonicEntry OBJECT-TYPE SYNTAX Lanpm14HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm14HarmonicSubmeterIndex } ::= { lanpm14HarmonicTable 1 } Lanpm14HarmonicEntry ::= SEQUENCE { lanpm14HarmonicSubmeterIndex Integer32, lanpm14HarmonicSelector Integer32, lanpm14HarmonicVTHD Opaque, lanpm14HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.4.1.1 lanpm14HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm14HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.4.1.2 lanpm14HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm14HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.4.1.3 lanpm14HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm14HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.14.4.1.4 lanpm14HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm14HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15 lanpm15 OBJECT IDENTIFIER ::= { lanpm 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1 lanpm15BasicInfo OBJECT IDENTIFIER ::= { lanpm15 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.1 lanpm15Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm15BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.2 lanpm15Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm15BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.3 lanpm15ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm15BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.4 lanpm15Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm15BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.5 lanpm15PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.5.1 lanpm15PtEntry OBJECT-TYPE SYNTAX Lanpm15PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15PtIndex } ::= { lanpm15PtTable 1 } Lanpm15PtEntry ::= SEQUENCE { lanpm15PtIndex Integer32, lanpm15PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.5.1.1 lanpm15PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm15PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.5.1.2 lanpm15PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm15PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.6 lanpm15CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.6.1 lanpm15CtEntry OBJECT-TYPE SYNTAX Lanpm15CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15CtIndex } ::= { lanpm15CtTable 1 } Lanpm15CtEntry ::= SEQUENCE { lanpm15CtIndex Integer32, lanpm15CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.6.1.1 lanpm15CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm15CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.6.1.2 lanpm15CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm15CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.9 lanpm15DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm15BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.10 lanpm15DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm15BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.11 lanpm15AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm15BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.12 lanpm15AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm15BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.13 lanpm15PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm15BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.14 lanpm15RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm15BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.15 lanpm15ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm15BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.1.16 lanpm15StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm15BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2 lanpm15ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1 lanpm15ChEntry OBJECT-TYPE SYNTAX Lanpm15ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15ChSubmeterIndex } ::= { lanpm15ChTable 1 } Lanpm15ChEntry ::= SEQUENCE { lanpm15ChSubmeterIndex Integer32, lanpm15ChName OCTET STRING, lanpm15ChVoltage Opaque, lanpm15ChCurrent Opaque, lanpm15ChKW Opaque, lanpm15ChKvar Opaque, lanpm15ChKVA Opaque, lanpm15ChPF Opaque, lanpm15ChKWh Opaque, lanpm15ChKvarh Opaque, lanpm15ChKVAh Opaque, lanpm15ChActualDemand Opaque, lanpm15ChForecastDemand Opaque, lanpm15ChMaxDemandH Opaque, lanpm15ChMaxDemandD Opaque, lanpm15ChMaxDemandM Opaque, lanpm15ChElectricityD Opaque, lanpm15ChElectricityM Opaque, lanpm15ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.0 lanpm15ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm15ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.1 lanpm15ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm15ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.2 lanpm15ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm15ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.3 lanpm15ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm15ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.4 lanpm15ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm15ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.5 lanpm15ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm15ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.6 lanpm15ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm15ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.7 lanpm15ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm15ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.8 lanpm15ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm15ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.9 lanpm15ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm15ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.10 lanpm15ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm15ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.11 lanpm15ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm15ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.12 lanpm15ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm15ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.13 lanpm15ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm15ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.14 lanpm15ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm15ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.15 lanpm15ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm15ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.16 lanpm15ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm15ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.17 lanpm15ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm15ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.2.1.18 lanpm15ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm15ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3 lanpm15IOinfo OBJECT IDENTIFIER ::= { lanpm15 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.1 lanpm15DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.1.1 lanpm15DIEntry OBJECT-TYPE SYNTAX Lanpm15DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15DIIndex } ::= { lanpm15DITable 1 } Lanpm15DIEntry ::= SEQUENCE { lanpm15DIIndex Integer32, lanpm15DIName OCTET STRING, lanpm15DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.1.1.1 lanpm15DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm15DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.1.1.2 lanpm15DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm15DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.1.1.3 lanpm15DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm15DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.2 lanpm15DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.2.1 lanpm15DOEntry OBJECT-TYPE SYNTAX Lanpm15DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15DOIndex } ::= { lanpm15DOTable 1 } Lanpm15DOEntry ::= SEQUENCE { lanpm15DOIndex Integer32, lanpm15DOName OCTET STRING, lanpm15DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.2.1.1 lanpm15DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm15DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.2.1.2 lanpm15DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm15DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.2.1.3 lanpm15DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm15DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.3 lanpm15AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.3.1 lanpm15AIEntry OBJECT-TYPE SYNTAX Lanpm15AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15AIIndex } ::= { lanpm15AITable 1 } Lanpm15AIEntry ::= SEQUENCE { lanpm15AIIndex Integer32, lanpm15AIName OCTET STRING, lanpm15AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.3.1.1 lanpm15AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm15AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.3.1.2 lanpm15AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm15AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.3.1.3 lanpm15AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm15AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.4 lanpm15AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.4.1 lanpm15AOEntry OBJECT-TYPE SYNTAX Lanpm15AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15AOIndex } ::= { lanpm15AOTable 1 } Lanpm15AOEntry ::= SEQUENCE { lanpm15AOIndex Integer32, lanpm15AOName OCTET STRING, lanpm15AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.4.1.1 lanpm15AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm15AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.4.1.2 lanpm15AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm15AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.3.4.1.3 lanpm15AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm15AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.4 lanpm15HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm15HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm15 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.4.1 lanpm15HarmonicEntry OBJECT-TYPE SYNTAX Lanpm15HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm15HarmonicSubmeterIndex } ::= { lanpm15HarmonicTable 1 } Lanpm15HarmonicEntry ::= SEQUENCE { lanpm15HarmonicSubmeterIndex Integer32, lanpm15HarmonicSelector Integer32, lanpm15HarmonicVTHD Opaque, lanpm15HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.4.1.1 lanpm15HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm15HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.4.1.2 lanpm15HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm15HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.4.1.3 lanpm15HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm15HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.15.4.1.4 lanpm15HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm15HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16 lanpm16 OBJECT IDENTIFIER ::= { lanpm 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1 lanpm16BasicInfo OBJECT IDENTIFIER ::= { lanpm16 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.1 lanpm16Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter." ::= { lanpm16BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.2 lanpm16Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the power meter ( Com1 / Com2 / IP:Port )." ::= { lanpm16BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.3 lanpm16ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the power meter." ::= { lanpm16BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.4 lanpm16Name OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter. Format : module name(nickname) " ::= { lanpm16BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.5 lanpm16PtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.5.1 lanpm16PtEntry OBJECT-TYPE SYNTAX Lanpm16PtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16PtIndex } ::= { lanpm16PtTable 1 } Lanpm16PtEntry ::= SEQUENCE { lanpm16PtIndex Integer32, lanpm16PtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.5.1.1 lanpm16PtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PT Value." ::= { lanpm16PtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.5.1.2 lanpm16PtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PT value of the power meter." ::= { lanpm16PtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.6 lanpm16CtTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.6.1 lanpm16CtEntry OBJECT-TYPE SYNTAX Lanpm16CtEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16CtIndex } ::= { lanpm16CtTable 1 } Lanpm16CtEntry ::= SEQUENCE { lanpm16CtIndex Integer32, lanpm16CtValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.6.1.1 lanpm16CtIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the CT Value." ::= { lanpm16CtEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.6.1.2 lanpm16CtValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The CT value of the power meter." ::= { lanpm16CtEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.9 lanpm16DIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DI channel of the power meter." ::= { lanpm16BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.10 lanpm16DOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the DO channel of the power meter." ::= { lanpm16BasicInfo 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.11 lanpm16AIAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AI channel of the power meter." ::= { lanpm16BasicInfo 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.12 lanpm16AOAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the AO channel of the power meter." ::= { lanpm16BasicInfo 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.13 lanpm16PollingTimeout OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Polling Timeout' indicates the time interval for PMC to send command to the power meter and wait for the response. The unit is millisecond." ::= { lanpm16BasicInfo 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.14 lanpm16RetryInterval OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The 'Retry Interval' indicates the time interval for PMC to resend command to the power meter when it¡¦s in the timeout status. The unit is second." ::= { lanpm16BasicInfo 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.15 lanpm16ScanRate OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The time interval for PMC to periodically retrieve the power data. The unit is second." ::= { lanpm16BasicInfo 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.1.16 lanpm16StatusCode OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The status code of the power meter. (-1=Initializing, 0=Failed, 1=Success) " ::= { lanpm16BasicInfo 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2 lanpm16ChTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1 lanpm16ChEntry OBJECT-TYPE SYNTAX Lanpm16ChEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16ChSubmeterIndex } ::= { lanpm16ChTable 1 } Lanpm16ChEntry ::= SEQUENCE { lanpm16ChSubmeterIndex Integer32, lanpm16ChName OCTET STRING, lanpm16ChVoltage Opaque, lanpm16ChCurrent Opaque, lanpm16ChKW Opaque, lanpm16ChKvar Opaque, lanpm16ChKVA Opaque, lanpm16ChPF Opaque, lanpm16ChKWh Opaque, lanpm16ChKvarh Opaque, lanpm16ChKVAh Opaque, lanpm16ChActualDemand Opaque, lanpm16ChForecastDemand Opaque, lanpm16ChMaxDemandH Opaque, lanpm16ChMaxDemandD Opaque, lanpm16ChMaxDemandM Opaque, lanpm16ChElectricityD Opaque, lanpm16ChElectricityM Opaque, lanpm16ChElectricityY Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.0 lanpm16ChSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm16ChEntry 0 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.1 lanpm16ChName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The user-defined name of the Loop/Phase." ::= { lanpm16ChEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.2 lanpm16ChVoltage OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The voltage value of the Loop/Phase." ::= { lanpm16ChEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.3 lanpm16ChCurrent OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The current value of the Loop/Phase." ::= { lanpm16ChEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.4 lanpm16ChKW OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KW value of the Loop/Phase." ::= { lanpm16ChEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.5 lanpm16ChKvar OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvar value of the Loop/Phase." ::= { lanpm16ChEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.6 lanpm16ChKVA OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVA value of the Loop/Phase." ::= { lanpm16ChEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.7 lanpm16ChPF OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The PF value of the Loop/Phase." ::= { lanpm16ChEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.8 lanpm16ChKWh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KWh value of the Loop/Phase." ::= { lanpm16ChEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.9 lanpm16ChKvarh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Kvarh value of the Loop/Phase." ::= { lanpm16ChEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.10 lanpm16ChKVAh OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The KVAh value of the Loop/Phase." ::= { lanpm16ChEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.11 lanpm16ChActualDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The actual demand of the Loop/Phase." ::= { lanpm16ChEntry 11 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.12 lanpm16ChForecastDemand OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The forecast demand of the Loop/Phase." ::= { lanpm16ChEntry 12 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.13 lanpm16ChMaxDemandH OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The hourly max. demand of the Loop/Phase." ::= { lanpm16ChEntry 13 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.14 lanpm16ChMaxDemandD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily max. demand of the Loop/Phase." ::= { lanpm16ChEntry 14 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.15 lanpm16ChMaxDemandM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly max. demand of the Loop/Phase." ::= { lanpm16ChEntry 15 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.16 lanpm16ChElectricityD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The daily accumulated electricity of the Loop/Phase." ::= { lanpm16ChEntry 16 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.17 lanpm16ChElectricityM OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The monthly accumulated electricity of the Loop/Phase." ::= { lanpm16ChEntry 17 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.2.1.18 lanpm16ChElectricityY OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The yearly accumulated electricity of the Loop/Phase." ::= { lanpm16ChEntry 18 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3 lanpm16IOinfo OBJECT IDENTIFIER ::= { lanpm16 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.1 lanpm16DITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16IOinfo 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.1.1 lanpm16DIEntry OBJECT-TYPE SYNTAX Lanpm16DIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16DIIndex } ::= { lanpm16DITable 1 } Lanpm16DIEntry ::= SEQUENCE { lanpm16DIIndex Integer32, lanpm16DIName OCTET STRING, lanpm16DIValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.1.1.1 lanpm16DIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DI channel." ::= { lanpm16DIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.1.1.2 lanpm16DIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DI channel." ::= { lanpm16DIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.1.1.3 lanpm16DIValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter DI channel." ::= { lanpm16DIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.2 lanpm16DOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16IOinfo 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.2.1 lanpm16DOEntry OBJECT-TYPE SYNTAX Lanpm16DOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16DOIndex } ::= { lanpm16DOTable 1 } Lanpm16DOEntry ::= SEQUENCE { lanpm16DOIndex Integer32, lanpm16DOName OCTET STRING, lanpm16DOValue Integer32 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.2.1.1 lanpm16DOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter DO channel." ::= { lanpm16DOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.2.1.2 lanpm16DOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter DO channel." ::= { lanpm16DOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.2.1.3 lanpm16DOValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter DO channel." ::= { lanpm16DOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.3 lanpm16AITable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16IOinfo 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.3.1 lanpm16AIEntry OBJECT-TYPE SYNTAX Lanpm16AIEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16AIIndex } ::= { lanpm16AITable 1 } Lanpm16AIEntry ::= SEQUENCE { lanpm16AIIndex Integer32, lanpm16AIName OCTET STRING, lanpm16AIValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.3.1.1 lanpm16AIIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AI channel." ::= { lanpm16AIEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.3.1.2 lanpm16AIName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AI channel." ::= { lanpm16AIEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.3.1.3 lanpm16AIValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the power meter AI channel." ::= { lanpm16AIEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.4 lanpm16AOTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16IOinfo 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.4.1 lanpm16AOEntry OBJECT-TYPE SYNTAX Lanpm16AOEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16AOIndex } ::= { lanpm16AOTable 1 } Lanpm16AOEntry ::= SEQUENCE { lanpm16AOIndex Integer32, lanpm16AOName OCTET STRING, lanpm16AOValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.4.1.1 lanpm16AOIndex OBJECT-TYPE SYNTAX Integer32 (0..3) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the power meter AO channel." ::= { lanpm16AOEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.4.1.2 lanpm16AOName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the power meter AO channel." ::= { lanpm16AOEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.3.4.1.3 lanpm16AOValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the power meter AO channel." ::= { lanpm16AOEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.4 lanpm16HarmonicTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanpm16HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanpm16 4 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.4.1 lanpm16HarmonicEntry OBJECT-TYPE SYNTAX Lanpm16HarmonicEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanpm16HarmonicSubmeterIndex } ::= { lanpm16HarmonicTable 1 } Lanpm16HarmonicEntry ::= SEQUENCE { lanpm16HarmonicSubmeterIndex Integer32, lanpm16HarmonicSelector Integer32, lanpm16HarmonicVTHD Opaque, lanpm16HarmonicITHD Opaque } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.4.1.1 lanpm16HarmonicSubmeterIndex OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Submeter." ::= { lanpm16HarmonicEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.4.1.2 lanpm16HarmonicSelector OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Harmonic Selector: 0: Disable 1: Phase A / Specific CT 2: Phase B / Specific CT 3: Phase C / Specific CT " ::= { lanpm16HarmonicEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.4.1.3 lanpm16HarmonicVTHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - VTHD Value" ::= { lanpm16HarmonicEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.2.3.16.4.1.4 lanpm16HarmonicITHD OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "Harmonic - ITHD Value" ::= { lanpm16HarmonicEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3 ioModuleInfo OBJECT IDENTIFIER ::= { pmd4206 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1 com1io OBJECT IDENTIFIER ::= { ioModuleInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1 com1io1 OBJECT IDENTIFIER ::= { com1io 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1 com1io1BasicInfo OBJECT IDENTIFIER ::= { com1io1 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.1 com1io1Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io1BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.2 com1io1Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io1BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.3 com1io1ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io1BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.4 com1io1ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io1BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.5 com1io1ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io1BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.6 com1io1DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io1BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.7 com1io1CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io1BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.8 com1io1InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io1BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.1.9 com1io1HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io1BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2 com1io1DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io1DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io1 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1 com1io1DiscInputEntry OBJECT-TYPE SYNTAX Com1io1DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io1DiscInputIndex } ::= { com1io1DiscInputTable 1 } Com1io1DiscInputEntry ::= SEQUENCE { com1io1DiscInputIndex Integer32, com1io1DiscInputName OCTET STRING, com1io1DiscInputValue Integer32, com1io1DiscInputModbusAdd Integer32, com1io1DiscInputCounterValue Counter32, com1io1DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1.1 com1io1DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io1DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1.2 com1io1DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io1DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1.3 com1io1DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io1DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1.4 com1io1DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io1DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1.5 com1io1DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io1DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.2.1.6 com1io1DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io1DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3 com1io1CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io1CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io1 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3.1 com1io1CoilOutputEntry OBJECT-TYPE SYNTAX Com1io1CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io1CoilOutputIndex } ::= { com1io1CoilOutputTable 1 } Com1io1CoilOutputEntry ::= SEQUENCE { com1io1CoilOutputIndex Integer32, com1io1CoilOutputName OCTET STRING, com1io1CoilOutputValue Integer32, com1io1CoilOutputModbusAdd Integer32, com1io1CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3.1.1 com1io1CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io1CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3.1.2 com1io1CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io1CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3.1.3 com1io1CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io1CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3.1.4 com1io1CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io1CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.3.1.5 com1io1CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io1CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4 com1io1InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io1InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io1 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1 com1io1InputRegEntry OBJECT-TYPE SYNTAX Com1io1InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io1InputRegIndex } ::= { com1io1InputRegTable 1 } Com1io1InputRegEntry ::= SEQUENCE { com1io1InputRegIndex Integer32, com1io1InputRegName OCTET STRING, com1io1InputRegValue Opaque, com1io1InputRegModbusAdd Integer32, com1io1InputRegType OCTET STRING, com1io1InputRegScaleRatio Opaque, com1io1InputRegOffset Opaque, com1io1InputRegDeadband Opaque, com1io1InputRegScaleMin Opaque, com1io1InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.1 com1io1InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io1InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.2 com1io1InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io1InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.3 com1io1InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io1InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.4 com1io1InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io1InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.5 com1io1InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io1InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.6 com1io1InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io1InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.7 com1io1InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io1InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.8 com1io1InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io1InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.9 com1io1InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io1InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.4.1.10 com1io1InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io1InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5 com1io1HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io1HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io1 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1 com1io1HoldingRegEntry OBJECT-TYPE SYNTAX Com1io1HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io1HoldingRegIndex } ::= { com1io1HoldingRegTable 1 } Com1io1HoldingRegEntry ::= SEQUENCE { com1io1HoldingRegIndex Integer32, com1io1HoldingRegName OCTET STRING, com1io1HoldingRegValue Opaque, com1io1HoldingRegModbusAdd Integer32, com1io1HoldingRegType OCTET STRING, com1io1HoldingRegScaleRatio Opaque, com1io1HoldingRegOffset Opaque, com1io1HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.1 com1io1HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io1HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.2 com1io1HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io1HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.3 com1io1HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io1HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.4 com1io1HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io1HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.5 com1io1HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io1HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.6 com1io1HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io1HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.7 com1io1HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io1HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.1.5.1.8 com1io1HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io1HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2 com1io2 OBJECT IDENTIFIER ::= { com1io 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1 com1io2BasicInfo OBJECT IDENTIFIER ::= { com1io2 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.1 com1io2Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io2BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.2 com1io2Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io2BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.3 com1io2ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io2BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.4 com1io2ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io2BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.5 com1io2ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io2BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.6 com1io2DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io2BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.7 com1io2CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io2BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.8 com1io2InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io2BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.1.9 com1io2HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io2BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2 com1io2DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io2DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io2 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1 com1io2DiscInputEntry OBJECT-TYPE SYNTAX Com1io2DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io2DiscInputIndex } ::= { com1io2DiscInputTable 1 } Com1io2DiscInputEntry ::= SEQUENCE { com1io2DiscInputIndex Integer32, com1io2DiscInputName OCTET STRING, com1io2DiscInputValue Integer32, com1io2DiscInputModbusAdd Integer32, com1io2DiscInputCounterValue Counter32, com1io2DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1.1 com1io2DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io2DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1.2 com1io2DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io2DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1.3 com1io2DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io2DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1.4 com1io2DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io2DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1.5 com1io2DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io2DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.2.1.6 com1io2DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io2DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3 com1io2CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io2CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io2 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3.1 com1io2CoilOutputEntry OBJECT-TYPE SYNTAX Com1io2CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io2CoilOutputIndex } ::= { com1io2CoilOutputTable 1 } Com1io2CoilOutputEntry ::= SEQUENCE { com1io2CoilOutputIndex Integer32, com1io2CoilOutputName OCTET STRING, com1io2CoilOutputValue Integer32, com1io2CoilOutputModbusAdd Integer32, com1io2CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3.1.1 com1io2CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io2CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3.1.2 com1io2CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io2CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3.1.3 com1io2CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io2CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3.1.4 com1io2CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io2CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.3.1.5 com1io2CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io2CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4 com1io2InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io2InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io2 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1 com1io2InputRegEntry OBJECT-TYPE SYNTAX Com1io2InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io2InputRegIndex } ::= { com1io2InputRegTable 1 } Com1io2InputRegEntry ::= SEQUENCE { com1io2InputRegIndex Integer32, com1io2InputRegName OCTET STRING, com1io2InputRegValue Opaque, com1io2InputRegModbusAdd Integer32, com1io2InputRegType OCTET STRING, com1io2InputRegScaleRatio Opaque, com1io2InputRegOffset Opaque, com1io2InputRegDeadband Opaque, com1io2InputRegScaleMin Opaque, com1io2InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.1 com1io2InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io2InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.2 com1io2InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io2InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.3 com1io2InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io2InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.4 com1io2InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io2InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.5 com1io2InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io2InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.6 com1io2InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io2InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.7 com1io2InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io2InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.8 com1io2InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io2InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.9 com1io2InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io2InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.4.1.10 com1io2InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io2InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5 com1io2HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io2HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io2 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1 com1io2HoldingRegEntry OBJECT-TYPE SYNTAX Com1io2HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io2HoldingRegIndex } ::= { com1io2HoldingRegTable 1 } Com1io2HoldingRegEntry ::= SEQUENCE { com1io2HoldingRegIndex Integer32, com1io2HoldingRegName OCTET STRING, com1io2HoldingRegValue Opaque, com1io2HoldingRegModbusAdd Integer32, com1io2HoldingRegType OCTET STRING, com1io2HoldingRegScaleRatio Opaque, com1io2HoldingRegOffset Opaque, com1io2HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.1 com1io2HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io2HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.2 com1io2HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io2HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.3 com1io2HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io2HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.4 com1io2HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io2HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.5 com1io2HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io2HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.6 com1io2HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io2HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.7 com1io2HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io2HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.2.5.1.8 com1io2HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io2HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3 com1io3 OBJECT IDENTIFIER ::= { com1io 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1 com1io3BasicInfo OBJECT IDENTIFIER ::= { com1io3 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.1 com1io3Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io3BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.2 com1io3Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io3BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.3 com1io3ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io3BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.4 com1io3ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io3BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.5 com1io3ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io3BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.6 com1io3DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io3BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.7 com1io3CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io3BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.8 com1io3InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io3BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.1.9 com1io3HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io3BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2 com1io3DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io3DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io3 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1 com1io3DiscInputEntry OBJECT-TYPE SYNTAX Com1io3DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io3DiscInputIndex } ::= { com1io3DiscInputTable 1 } Com1io3DiscInputEntry ::= SEQUENCE { com1io3DiscInputIndex Integer32, com1io3DiscInputName OCTET STRING, com1io3DiscInputValue Integer32, com1io3DiscInputModbusAdd Integer32, com1io3DiscInputCounterValue Counter32, com1io3DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1.1 com1io3DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io3DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1.2 com1io3DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io3DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1.3 com1io3DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io3DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1.4 com1io3DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io3DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1.5 com1io3DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io3DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.2.1.6 com1io3DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io3DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3 com1io3CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io3CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io3 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3.1 com1io3CoilOutputEntry OBJECT-TYPE SYNTAX Com1io3CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io3CoilOutputIndex } ::= { com1io3CoilOutputTable 1 } Com1io3CoilOutputEntry ::= SEQUENCE { com1io3CoilOutputIndex Integer32, com1io3CoilOutputName OCTET STRING, com1io3CoilOutputValue Integer32, com1io3CoilOutputModbusAdd Integer32, com1io3CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3.1.1 com1io3CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io3CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3.1.2 com1io3CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io3CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3.1.3 com1io3CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io3CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3.1.4 com1io3CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io3CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.3.1.5 com1io3CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io3CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4 com1io3InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io3InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io3 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1 com1io3InputRegEntry OBJECT-TYPE SYNTAX Com1io3InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io3InputRegIndex } ::= { com1io3InputRegTable 1 } Com1io3InputRegEntry ::= SEQUENCE { com1io3InputRegIndex Integer32, com1io3InputRegName OCTET STRING, com1io3InputRegValue Opaque, com1io3InputRegModbusAdd Integer32, com1io3InputRegType OCTET STRING, com1io3InputRegScaleRatio Opaque, com1io3InputRegOffset Opaque, com1io3InputRegDeadband Opaque, com1io3InputRegScaleMin Opaque, com1io3InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.1 com1io3InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io3InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.2 com1io3InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io3InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.3 com1io3InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io3InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.4 com1io3InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io3InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.5 com1io3InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io3InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.6 com1io3InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io3InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.7 com1io3InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io3InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.8 com1io3InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io3InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.9 com1io3InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io3InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.4.1.10 com1io3InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io3InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5 com1io3HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io3HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io3 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1 com1io3HoldingRegEntry OBJECT-TYPE SYNTAX Com1io3HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io3HoldingRegIndex } ::= { com1io3HoldingRegTable 1 } Com1io3HoldingRegEntry ::= SEQUENCE { com1io3HoldingRegIndex Integer32, com1io3HoldingRegName OCTET STRING, com1io3HoldingRegValue Opaque, com1io3HoldingRegModbusAdd Integer32, com1io3HoldingRegType OCTET STRING, com1io3HoldingRegScaleRatio Opaque, com1io3HoldingRegOffset Opaque, com1io3HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.1 com1io3HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io3HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.2 com1io3HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io3HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.3 com1io3HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io3HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.4 com1io3HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io3HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.5 com1io3HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io3HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.6 com1io3HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io3HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.7 com1io3HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io3HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.3.5.1.8 com1io3HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io3HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4 com1io4 OBJECT IDENTIFIER ::= { com1io 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1 com1io4BasicInfo OBJECT IDENTIFIER ::= { com1io4 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.1 com1io4Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io4BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.2 com1io4Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io4BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.3 com1io4ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io4BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.4 com1io4ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io4BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.5 com1io4ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io4BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.6 com1io4DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io4BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.7 com1io4CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io4BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.8 com1io4InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io4BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.1.9 com1io4HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io4BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2 com1io4DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io4DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io4 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1 com1io4DiscInputEntry OBJECT-TYPE SYNTAX Com1io4DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io4DiscInputIndex } ::= { com1io4DiscInputTable 1 } Com1io4DiscInputEntry ::= SEQUENCE { com1io4DiscInputIndex Integer32, com1io4DiscInputName OCTET STRING, com1io4DiscInputValue Integer32, com1io4DiscInputModbusAdd Integer32, com1io4DiscInputCounterValue Counter32, com1io4DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1.1 com1io4DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io4DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1.2 com1io4DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io4DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1.3 com1io4DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io4DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1.4 com1io4DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io4DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1.5 com1io4DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io4DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.2.1.6 com1io4DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io4DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3 com1io4CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io4CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io4 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3.1 com1io4CoilOutputEntry OBJECT-TYPE SYNTAX Com1io4CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io4CoilOutputIndex } ::= { com1io4CoilOutputTable 1 } Com1io4CoilOutputEntry ::= SEQUENCE { com1io4CoilOutputIndex Integer32, com1io4CoilOutputName OCTET STRING, com1io4CoilOutputValue Integer32, com1io4CoilOutputModbusAdd Integer32, com1io4CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3.1.1 com1io4CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io4CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3.1.2 com1io4CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io4CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3.1.3 com1io4CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io4CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3.1.4 com1io4CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io4CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.3.1.5 com1io4CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io4CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4 com1io4InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io4InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io4 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1 com1io4InputRegEntry OBJECT-TYPE SYNTAX Com1io4InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io4InputRegIndex } ::= { com1io4InputRegTable 1 } Com1io4InputRegEntry ::= SEQUENCE { com1io4InputRegIndex Integer32, com1io4InputRegName OCTET STRING, com1io4InputRegValue Opaque, com1io4InputRegModbusAdd Integer32, com1io4InputRegType OCTET STRING, com1io4InputRegScaleRatio Opaque, com1io4InputRegOffset Opaque, com1io4InputRegDeadband Opaque, com1io4InputRegScaleMin Opaque, com1io4InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.1 com1io4InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io4InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.2 com1io4InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io4InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.3 com1io4InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io4InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.4 com1io4InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io4InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.5 com1io4InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io4InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.6 com1io4InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io4InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.7 com1io4InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io4InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.8 com1io4InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io4InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.9 com1io4InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io4InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.4.1.10 com1io4InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io4InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5 com1io4HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io4HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io4 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1 com1io4HoldingRegEntry OBJECT-TYPE SYNTAX Com1io4HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io4HoldingRegIndex } ::= { com1io4HoldingRegTable 1 } Com1io4HoldingRegEntry ::= SEQUENCE { com1io4HoldingRegIndex Integer32, com1io4HoldingRegName OCTET STRING, com1io4HoldingRegValue Opaque, com1io4HoldingRegModbusAdd Integer32, com1io4HoldingRegType OCTET STRING, com1io4HoldingRegScaleRatio Opaque, com1io4HoldingRegOffset Opaque, com1io4HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.1 com1io4HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io4HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.2 com1io4HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io4HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.3 com1io4HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io4HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.4 com1io4HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io4HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.5 com1io4HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io4HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.6 com1io4HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io4HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.7 com1io4HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io4HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.4.5.1.8 com1io4HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io4HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5 com1io5 OBJECT IDENTIFIER ::= { com1io 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1 com1io5BasicInfo OBJECT IDENTIFIER ::= { com1io5 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.1 com1io5Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io5BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.2 com1io5Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io5BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.3 com1io5ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io5BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.4 com1io5ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io5BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.5 com1io5ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io5BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.6 com1io5DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io5BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.7 com1io5CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io5BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.8 com1io5InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io5BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.1.9 com1io5HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io5BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2 com1io5DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io5DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io5 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1 com1io5DiscInputEntry OBJECT-TYPE SYNTAX Com1io5DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io5DiscInputIndex } ::= { com1io5DiscInputTable 1 } Com1io5DiscInputEntry ::= SEQUENCE { com1io5DiscInputIndex Integer32, com1io5DiscInputName OCTET STRING, com1io5DiscInputValue Integer32, com1io5DiscInputModbusAdd Integer32, com1io5DiscInputCounterValue Counter32, com1io5DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1.1 com1io5DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io5DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1.2 com1io5DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io5DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1.3 com1io5DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io5DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1.4 com1io5DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io5DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1.5 com1io5DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io5DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.2.1.6 com1io5DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io5DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3 com1io5CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io5CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io5 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3.1 com1io5CoilOutputEntry OBJECT-TYPE SYNTAX Com1io5CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io5CoilOutputIndex } ::= { com1io5CoilOutputTable 1 } Com1io5CoilOutputEntry ::= SEQUENCE { com1io5CoilOutputIndex Integer32, com1io5CoilOutputName OCTET STRING, com1io5CoilOutputValue Integer32, com1io5CoilOutputModbusAdd Integer32, com1io5CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3.1.1 com1io5CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io5CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3.1.2 com1io5CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io5CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3.1.3 com1io5CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io5CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3.1.4 com1io5CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io5CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.3.1.5 com1io5CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io5CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4 com1io5InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io5InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io5 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1 com1io5InputRegEntry OBJECT-TYPE SYNTAX Com1io5InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io5InputRegIndex } ::= { com1io5InputRegTable 1 } Com1io5InputRegEntry ::= SEQUENCE { com1io5InputRegIndex Integer32, com1io5InputRegName OCTET STRING, com1io5InputRegValue Opaque, com1io5InputRegModbusAdd Integer32, com1io5InputRegType OCTET STRING, com1io5InputRegScaleRatio Opaque, com1io5InputRegOffset Opaque, com1io5InputRegDeadband Opaque, com1io5InputRegScaleMin Opaque, com1io5InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.1 com1io5InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io5InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.2 com1io5InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io5InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.3 com1io5InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io5InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.4 com1io5InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io5InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.5 com1io5InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io5InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.6 com1io5InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io5InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.7 com1io5InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io5InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.8 com1io5InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io5InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.9 com1io5InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io5InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.4.1.10 com1io5InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io5InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5 com1io5HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io5HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io5 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1 com1io5HoldingRegEntry OBJECT-TYPE SYNTAX Com1io5HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io5HoldingRegIndex } ::= { com1io5HoldingRegTable 1 } Com1io5HoldingRegEntry ::= SEQUENCE { com1io5HoldingRegIndex Integer32, com1io5HoldingRegName OCTET STRING, com1io5HoldingRegValue Opaque, com1io5HoldingRegModbusAdd Integer32, com1io5HoldingRegType OCTET STRING, com1io5HoldingRegScaleRatio Opaque, com1io5HoldingRegOffset Opaque, com1io5HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.1 com1io5HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io5HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.2 com1io5HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io5HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.3 com1io5HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io5HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.4 com1io5HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io5HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.5 com1io5HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io5HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.6 com1io5HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io5HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.7 com1io5HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io5HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.5.5.1.8 com1io5HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io5HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6 com1io6 OBJECT IDENTIFIER ::= { com1io 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1 com1io6BasicInfo OBJECT IDENTIFIER ::= { com1io6 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.1 com1io6Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io6BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.2 com1io6Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io6BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.3 com1io6ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io6BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.4 com1io6ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io6BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.5 com1io6ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io6BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.6 com1io6DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io6BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.7 com1io6CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io6BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.8 com1io6InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io6BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.1.9 com1io6HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io6BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2 com1io6DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io6DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io6 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1 com1io6DiscInputEntry OBJECT-TYPE SYNTAX Com1io6DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io6DiscInputIndex } ::= { com1io6DiscInputTable 1 } Com1io6DiscInputEntry ::= SEQUENCE { com1io6DiscInputIndex Integer32, com1io6DiscInputName OCTET STRING, com1io6DiscInputValue Integer32, com1io6DiscInputModbusAdd Integer32, com1io6DiscInputCounterValue Counter32, com1io6DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1.1 com1io6DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io6DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1.2 com1io6DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io6DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1.3 com1io6DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io6DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1.4 com1io6DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io6DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1.5 com1io6DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io6DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.2.1.6 com1io6DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io6DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3 com1io6CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io6CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io6 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3.1 com1io6CoilOutputEntry OBJECT-TYPE SYNTAX Com1io6CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io6CoilOutputIndex } ::= { com1io6CoilOutputTable 1 } Com1io6CoilOutputEntry ::= SEQUENCE { com1io6CoilOutputIndex Integer32, com1io6CoilOutputName OCTET STRING, com1io6CoilOutputValue Integer32, com1io6CoilOutputModbusAdd Integer32, com1io6CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3.1.1 com1io6CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io6CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3.1.2 com1io6CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io6CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3.1.3 com1io6CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io6CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3.1.4 com1io6CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io6CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.3.1.5 com1io6CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io6CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4 com1io6InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io6InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io6 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1 com1io6InputRegEntry OBJECT-TYPE SYNTAX Com1io6InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io6InputRegIndex } ::= { com1io6InputRegTable 1 } Com1io6InputRegEntry ::= SEQUENCE { com1io6InputRegIndex Integer32, com1io6InputRegName OCTET STRING, com1io6InputRegValue Opaque, com1io6InputRegModbusAdd Integer32, com1io6InputRegType OCTET STRING, com1io6InputRegScaleRatio Opaque, com1io6InputRegOffset Opaque, com1io6InputRegDeadband Opaque, com1io6InputRegScaleMin Opaque, com1io6InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.1 com1io6InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io6InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.2 com1io6InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io6InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.3 com1io6InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io6InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.4 com1io6InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io6InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.5 com1io6InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io6InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.6 com1io6InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io6InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.7 com1io6InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io6InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.8 com1io6InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io6InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.9 com1io6InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io6InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.4.1.10 com1io6InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io6InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5 com1io6HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io6HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io6 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1 com1io6HoldingRegEntry OBJECT-TYPE SYNTAX Com1io6HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io6HoldingRegIndex } ::= { com1io6HoldingRegTable 1 } Com1io6HoldingRegEntry ::= SEQUENCE { com1io6HoldingRegIndex Integer32, com1io6HoldingRegName OCTET STRING, com1io6HoldingRegValue Opaque, com1io6HoldingRegModbusAdd Integer32, com1io6HoldingRegType OCTET STRING, com1io6HoldingRegScaleRatio Opaque, com1io6HoldingRegOffset Opaque, com1io6HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.1 com1io6HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io6HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.2 com1io6HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io6HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.3 com1io6HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io6HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.4 com1io6HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io6HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.5 com1io6HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io6HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.6 com1io6HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io6HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.7 com1io6HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io6HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.6.5.1.8 com1io6HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io6HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7 com1io7 OBJECT IDENTIFIER ::= { com1io 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1 com1io7BasicInfo OBJECT IDENTIFIER ::= { com1io7 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.1 com1io7Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io7BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.2 com1io7Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io7BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.3 com1io7ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io7BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.4 com1io7ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io7BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.5 com1io7ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io7BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.6 com1io7DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io7BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.7 com1io7CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io7BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.8 com1io7InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io7BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.1.9 com1io7HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io7BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2 com1io7DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io7DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io7 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1 com1io7DiscInputEntry OBJECT-TYPE SYNTAX Com1io7DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io7DiscInputIndex } ::= { com1io7DiscInputTable 1 } Com1io7DiscInputEntry ::= SEQUENCE { com1io7DiscInputIndex Integer32, com1io7DiscInputName OCTET STRING, com1io7DiscInputValue Integer32, com1io7DiscInputModbusAdd Integer32, com1io7DiscInputCounterValue Counter32, com1io7DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1.1 com1io7DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io7DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1.2 com1io7DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io7DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1.3 com1io7DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io7DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1.4 com1io7DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io7DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1.5 com1io7DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io7DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.2.1.6 com1io7DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io7DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3 com1io7CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io7CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io7 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3.1 com1io7CoilOutputEntry OBJECT-TYPE SYNTAX Com1io7CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io7CoilOutputIndex } ::= { com1io7CoilOutputTable 1 } Com1io7CoilOutputEntry ::= SEQUENCE { com1io7CoilOutputIndex Integer32, com1io7CoilOutputName OCTET STRING, com1io7CoilOutputValue Integer32, com1io7CoilOutputModbusAdd Integer32, com1io7CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3.1.1 com1io7CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io7CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3.1.2 com1io7CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io7CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3.1.3 com1io7CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io7CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3.1.4 com1io7CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io7CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.3.1.5 com1io7CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io7CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4 com1io7InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io7InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io7 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1 com1io7InputRegEntry OBJECT-TYPE SYNTAX Com1io7InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io7InputRegIndex } ::= { com1io7InputRegTable 1 } Com1io7InputRegEntry ::= SEQUENCE { com1io7InputRegIndex Integer32, com1io7InputRegName OCTET STRING, com1io7InputRegValue Opaque, com1io7InputRegModbusAdd Integer32, com1io7InputRegType OCTET STRING, com1io7InputRegScaleRatio Opaque, com1io7InputRegOffset Opaque, com1io7InputRegDeadband Opaque, com1io7InputRegScaleMin Opaque, com1io7InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.1 com1io7InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io7InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.2 com1io7InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io7InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.3 com1io7InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io7InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.4 com1io7InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io7InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.5 com1io7InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io7InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.6 com1io7InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io7InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.7 com1io7InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io7InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.8 com1io7InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io7InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.9 com1io7InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io7InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.4.1.10 com1io7InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io7InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5 com1io7HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io7HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io7 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1 com1io7HoldingRegEntry OBJECT-TYPE SYNTAX Com1io7HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io7HoldingRegIndex } ::= { com1io7HoldingRegTable 1 } Com1io7HoldingRegEntry ::= SEQUENCE { com1io7HoldingRegIndex Integer32, com1io7HoldingRegName OCTET STRING, com1io7HoldingRegValue Opaque, com1io7HoldingRegModbusAdd Integer32, com1io7HoldingRegType OCTET STRING, com1io7HoldingRegScaleRatio Opaque, com1io7HoldingRegOffset Opaque, com1io7HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.1 com1io7HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io7HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.2 com1io7HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io7HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.3 com1io7HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io7HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.4 com1io7HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io7HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.5 com1io7HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io7HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.6 com1io7HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io7HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.7 com1io7HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io7HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.7.5.1.8 com1io7HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io7HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8 com1io8 OBJECT IDENTIFIER ::= { com1io 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1 com1io8BasicInfo OBJECT IDENTIFIER ::= { com1io8 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.1 com1io8Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io8BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.2 com1io8Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io8BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.3 com1io8ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io8BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.4 com1io8ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io8BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.5 com1io8ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io8BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.6 com1io8DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io8BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.7 com1io8CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io8BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.8 com1io8InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io8BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.1.9 com1io8HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io8BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2 com1io8DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io8DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io8 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1 com1io8DiscInputEntry OBJECT-TYPE SYNTAX Com1io8DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io8DiscInputIndex } ::= { com1io8DiscInputTable 1 } Com1io8DiscInputEntry ::= SEQUENCE { com1io8DiscInputIndex Integer32, com1io8DiscInputName OCTET STRING, com1io8DiscInputValue Integer32, com1io8DiscInputModbusAdd Integer32, com1io8DiscInputCounterValue Counter32, com1io8DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1.1 com1io8DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io8DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1.2 com1io8DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io8DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1.3 com1io8DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io8DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1.4 com1io8DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io8DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1.5 com1io8DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io8DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.2.1.6 com1io8DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io8DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3 com1io8CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io8CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io8 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3.1 com1io8CoilOutputEntry OBJECT-TYPE SYNTAX Com1io8CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io8CoilOutputIndex } ::= { com1io8CoilOutputTable 1 } Com1io8CoilOutputEntry ::= SEQUENCE { com1io8CoilOutputIndex Integer32, com1io8CoilOutputName OCTET STRING, com1io8CoilOutputValue Integer32, com1io8CoilOutputModbusAdd Integer32, com1io8CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3.1.1 com1io8CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io8CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3.1.2 com1io8CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io8CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3.1.3 com1io8CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io8CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3.1.4 com1io8CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io8CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.3.1.5 com1io8CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io8CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4 com1io8InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io8InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io8 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1 com1io8InputRegEntry OBJECT-TYPE SYNTAX Com1io8InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io8InputRegIndex } ::= { com1io8InputRegTable 1 } Com1io8InputRegEntry ::= SEQUENCE { com1io8InputRegIndex Integer32, com1io8InputRegName OCTET STRING, com1io8InputRegValue Opaque, com1io8InputRegModbusAdd Integer32, com1io8InputRegType OCTET STRING, com1io8InputRegScaleRatio Opaque, com1io8InputRegOffset Opaque, com1io8InputRegDeadband Opaque, com1io8InputRegScaleMin Opaque, com1io8InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.1 com1io8InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io8InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.2 com1io8InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io8InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.3 com1io8InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io8InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.4 com1io8InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io8InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.5 com1io8InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io8InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.6 com1io8InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io8InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.7 com1io8InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io8InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.8 com1io8InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io8InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.9 com1io8InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io8InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.4.1.10 com1io8InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io8InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5 com1io8HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io8HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io8 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1 com1io8HoldingRegEntry OBJECT-TYPE SYNTAX Com1io8HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io8HoldingRegIndex } ::= { com1io8HoldingRegTable 1 } Com1io8HoldingRegEntry ::= SEQUENCE { com1io8HoldingRegIndex Integer32, com1io8HoldingRegName OCTET STRING, com1io8HoldingRegValue Opaque, com1io8HoldingRegModbusAdd Integer32, com1io8HoldingRegType OCTET STRING, com1io8HoldingRegScaleRatio Opaque, com1io8HoldingRegOffset Opaque, com1io8HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.1 com1io8HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io8HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.2 com1io8HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io8HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.3 com1io8HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io8HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.4 com1io8HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io8HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.5 com1io8HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io8HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.6 com1io8HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io8HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.7 com1io8HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io8HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.8.5.1.8 com1io8HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io8HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9 com1io9 OBJECT IDENTIFIER ::= { com1io 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1 com1io9BasicInfo OBJECT IDENTIFIER ::= { com1io9 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.1 com1io9Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io9BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.2 com1io9Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io9BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.3 com1io9ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io9BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.4 com1io9ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io9BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.5 com1io9ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io9BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.6 com1io9DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io9BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.7 com1io9CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io9BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.8 com1io9InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io9BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.1.9 com1io9HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io9BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2 com1io9DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io9DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io9 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1 com1io9DiscInputEntry OBJECT-TYPE SYNTAX Com1io9DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io9DiscInputIndex } ::= { com1io9DiscInputTable 1 } Com1io9DiscInputEntry ::= SEQUENCE { com1io9DiscInputIndex Integer32, com1io9DiscInputName OCTET STRING, com1io9DiscInputValue Integer32, com1io9DiscInputModbusAdd Integer32, com1io9DiscInputCounterValue Counter32, com1io9DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1.1 com1io9DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io9DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1.2 com1io9DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io9DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1.3 com1io9DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io9DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1.4 com1io9DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io9DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1.5 com1io9DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io9DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.2.1.6 com1io9DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io9DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3 com1io9CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io9CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io9 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3.1 com1io9CoilOutputEntry OBJECT-TYPE SYNTAX Com1io9CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io9CoilOutputIndex } ::= { com1io9CoilOutputTable 1 } Com1io9CoilOutputEntry ::= SEQUENCE { com1io9CoilOutputIndex Integer32, com1io9CoilOutputName OCTET STRING, com1io9CoilOutputValue Integer32, com1io9CoilOutputModbusAdd Integer32, com1io9CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3.1.1 com1io9CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io9CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3.1.2 com1io9CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io9CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3.1.3 com1io9CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io9CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3.1.4 com1io9CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io9CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.3.1.5 com1io9CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io9CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4 com1io9InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io9InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io9 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1 com1io9InputRegEntry OBJECT-TYPE SYNTAX Com1io9InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io9InputRegIndex } ::= { com1io9InputRegTable 1 } Com1io9InputRegEntry ::= SEQUENCE { com1io9InputRegIndex Integer32, com1io9InputRegName OCTET STRING, com1io9InputRegValue Opaque, com1io9InputRegModbusAdd Integer32, com1io9InputRegType OCTET STRING, com1io9InputRegScaleRatio Opaque, com1io9InputRegOffset Opaque, com1io9InputRegDeadband Opaque, com1io9InputRegScaleMin Opaque, com1io9InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.1 com1io9InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io9InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.2 com1io9InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io9InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.3 com1io9InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io9InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.4 com1io9InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io9InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.5 com1io9InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io9InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.6 com1io9InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io9InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.7 com1io9InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io9InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.8 com1io9InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io9InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.9 com1io9InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io9InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.4.1.10 com1io9InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io9InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5 com1io9HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io9HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io9 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1 com1io9HoldingRegEntry OBJECT-TYPE SYNTAX Com1io9HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io9HoldingRegIndex } ::= { com1io9HoldingRegTable 1 } Com1io9HoldingRegEntry ::= SEQUENCE { com1io9HoldingRegIndex Integer32, com1io9HoldingRegName OCTET STRING, com1io9HoldingRegValue Opaque, com1io9HoldingRegModbusAdd Integer32, com1io9HoldingRegType OCTET STRING, com1io9HoldingRegScaleRatio Opaque, com1io9HoldingRegOffset Opaque, com1io9HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.1 com1io9HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io9HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.2 com1io9HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io9HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.3 com1io9HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io9HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.4 com1io9HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io9HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.5 com1io9HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io9HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.6 com1io9HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io9HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.7 com1io9HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io9HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.9.5.1.8 com1io9HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io9HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10 com1io10 OBJECT IDENTIFIER ::= { com1io 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1 com1io10BasicInfo OBJECT IDENTIFIER ::= { com1io10 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.1 com1io10Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io10BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.2 com1io10Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io10BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.3 com1io10ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io10BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.4 com1io10ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io10BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.5 com1io10ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io10BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.6 com1io10DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io10BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.7 com1io10CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io10BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.8 com1io10InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io10BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.1.9 com1io10HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io10BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2 com1io10DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io10DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io10 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1 com1io10DiscInputEntry OBJECT-TYPE SYNTAX Com1io10DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io10DiscInputIndex } ::= { com1io10DiscInputTable 1 } Com1io10DiscInputEntry ::= SEQUENCE { com1io10DiscInputIndex Integer32, com1io10DiscInputName OCTET STRING, com1io10DiscInputValue Integer32, com1io10DiscInputModbusAdd Integer32, com1io10DiscInputCounterValue Counter32, com1io10DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1.1 com1io10DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io10DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1.2 com1io10DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io10DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1.3 com1io10DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io10DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1.4 com1io10DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io10DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1.5 com1io10DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io10DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.2.1.6 com1io10DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io10DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3 com1io10CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io10CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io10 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3.1 com1io10CoilOutputEntry OBJECT-TYPE SYNTAX Com1io10CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io10CoilOutputIndex } ::= { com1io10CoilOutputTable 1 } Com1io10CoilOutputEntry ::= SEQUENCE { com1io10CoilOutputIndex Integer32, com1io10CoilOutputName OCTET STRING, com1io10CoilOutputValue Integer32, com1io10CoilOutputModbusAdd Integer32, com1io10CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3.1.1 com1io10CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io10CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3.1.2 com1io10CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io10CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3.1.3 com1io10CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io10CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3.1.4 com1io10CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io10CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.3.1.5 com1io10CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io10CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4 com1io10InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io10InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io10 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1 com1io10InputRegEntry OBJECT-TYPE SYNTAX Com1io10InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io10InputRegIndex } ::= { com1io10InputRegTable 1 } Com1io10InputRegEntry ::= SEQUENCE { com1io10InputRegIndex Integer32, com1io10InputRegName OCTET STRING, com1io10InputRegValue Opaque, com1io10InputRegModbusAdd Integer32, com1io10InputRegType OCTET STRING, com1io10InputRegScaleRatio Opaque, com1io10InputRegOffset Opaque, com1io10InputRegDeadband Opaque, com1io10InputRegScaleMin Opaque, com1io10InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.1 com1io10InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io10InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.2 com1io10InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io10InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.3 com1io10InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io10InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.4 com1io10InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io10InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.5 com1io10InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io10InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.6 com1io10InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io10InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.7 com1io10InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io10InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.8 com1io10InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io10InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.9 com1io10InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io10InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.4.1.10 com1io10InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io10InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5 com1io10HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io10HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io10 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1 com1io10HoldingRegEntry OBJECT-TYPE SYNTAX Com1io10HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io10HoldingRegIndex } ::= { com1io10HoldingRegTable 1 } Com1io10HoldingRegEntry ::= SEQUENCE { com1io10HoldingRegIndex Integer32, com1io10HoldingRegName OCTET STRING, com1io10HoldingRegValue Opaque, com1io10HoldingRegModbusAdd Integer32, com1io10HoldingRegType OCTET STRING, com1io10HoldingRegScaleRatio Opaque, com1io10HoldingRegOffset Opaque, com1io10HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.1 com1io10HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io10HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.2 com1io10HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io10HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.3 com1io10HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io10HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.4 com1io10HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io10HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.5 com1io10HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io10HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.6 com1io10HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io10HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.7 com1io10HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io10HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.10.5.1.8 com1io10HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io10HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11 com1io11 OBJECT IDENTIFIER ::= { com1io 11 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1 com1io11BasicInfo OBJECT IDENTIFIER ::= { com1io11 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.1 com1io11Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io11BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.2 com1io11Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io11BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.3 com1io11ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io11BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.4 com1io11ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io11BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.5 com1io11ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io11BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.6 com1io11DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io11BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.7 com1io11CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io11BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.8 com1io11InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io11BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.1.9 com1io11HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io11BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2 com1io11DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io11DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io11 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1 com1io11DiscInputEntry OBJECT-TYPE SYNTAX Com1io11DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io11DiscInputIndex } ::= { com1io11DiscInputTable 1 } Com1io11DiscInputEntry ::= SEQUENCE { com1io11DiscInputIndex Integer32, com1io11DiscInputName OCTET STRING, com1io11DiscInputValue Integer32, com1io11DiscInputModbusAdd Integer32, com1io11DiscInputCounterValue Counter32, com1io11DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1.1 com1io11DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io11DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1.2 com1io11DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io11DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1.3 com1io11DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io11DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1.4 com1io11DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io11DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1.5 com1io11DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io11DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.2.1.6 com1io11DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io11DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3 com1io11CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io11CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io11 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3.1 com1io11CoilOutputEntry OBJECT-TYPE SYNTAX Com1io11CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io11CoilOutputIndex } ::= { com1io11CoilOutputTable 1 } Com1io11CoilOutputEntry ::= SEQUENCE { com1io11CoilOutputIndex Integer32, com1io11CoilOutputName OCTET STRING, com1io11CoilOutputValue Integer32, com1io11CoilOutputModbusAdd Integer32, com1io11CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3.1.1 com1io11CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io11CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3.1.2 com1io11CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io11CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3.1.3 com1io11CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io11CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3.1.4 com1io11CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io11CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.3.1.5 com1io11CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io11CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4 com1io11InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io11InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io11 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1 com1io11InputRegEntry OBJECT-TYPE SYNTAX Com1io11InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io11InputRegIndex } ::= { com1io11InputRegTable 1 } Com1io11InputRegEntry ::= SEQUENCE { com1io11InputRegIndex Integer32, com1io11InputRegName OCTET STRING, com1io11InputRegValue Opaque, com1io11InputRegModbusAdd Integer32, com1io11InputRegType OCTET STRING, com1io11InputRegScaleRatio Opaque, com1io11InputRegOffset Opaque, com1io11InputRegDeadband Opaque, com1io11InputRegScaleMin Opaque, com1io11InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.1 com1io11InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io11InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.2 com1io11InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io11InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.3 com1io11InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io11InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.4 com1io11InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io11InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.5 com1io11InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io11InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.6 com1io11InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io11InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.7 com1io11InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io11InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.8 com1io11InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io11InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.9 com1io11InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io11InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.4.1.10 com1io11InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io11InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5 com1io11HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io11HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io11 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1 com1io11HoldingRegEntry OBJECT-TYPE SYNTAX Com1io11HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io11HoldingRegIndex } ::= { com1io11HoldingRegTable 1 } Com1io11HoldingRegEntry ::= SEQUENCE { com1io11HoldingRegIndex Integer32, com1io11HoldingRegName OCTET STRING, com1io11HoldingRegValue Opaque, com1io11HoldingRegModbusAdd Integer32, com1io11HoldingRegType OCTET STRING, com1io11HoldingRegScaleRatio Opaque, com1io11HoldingRegOffset Opaque, com1io11HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.1 com1io11HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io11HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.2 com1io11HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io11HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.3 com1io11HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io11HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.4 com1io11HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io11HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.5 com1io11HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io11HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.6 com1io11HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io11HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.7 com1io11HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io11HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.11.5.1.8 com1io11HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io11HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12 com1io12 OBJECT IDENTIFIER ::= { com1io 12 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1 com1io12BasicInfo OBJECT IDENTIFIER ::= { com1io12 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.1 com1io12Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io12BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.2 com1io12Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io12BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.3 com1io12ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io12BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.4 com1io12ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io12BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.5 com1io12ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io12BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.6 com1io12DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io12BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.7 com1io12CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io12BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.8 com1io12InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io12BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.1.9 com1io12HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io12BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2 com1io12DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io12DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io12 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1 com1io12DiscInputEntry OBJECT-TYPE SYNTAX Com1io12DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io12DiscInputIndex } ::= { com1io12DiscInputTable 1 } Com1io12DiscInputEntry ::= SEQUENCE { com1io12DiscInputIndex Integer32, com1io12DiscInputName OCTET STRING, com1io12DiscInputValue Integer32, com1io12DiscInputModbusAdd Integer32, com1io12DiscInputCounterValue Counter32, com1io12DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1.1 com1io12DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io12DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1.2 com1io12DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io12DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1.3 com1io12DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io12DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1.4 com1io12DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io12DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1.5 com1io12DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io12DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.2.1.6 com1io12DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io12DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3 com1io12CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io12CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io12 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3.1 com1io12CoilOutputEntry OBJECT-TYPE SYNTAX Com1io12CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io12CoilOutputIndex } ::= { com1io12CoilOutputTable 1 } Com1io12CoilOutputEntry ::= SEQUENCE { com1io12CoilOutputIndex Integer32, com1io12CoilOutputName OCTET STRING, com1io12CoilOutputValue Integer32, com1io12CoilOutputModbusAdd Integer32, com1io12CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3.1.1 com1io12CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io12CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3.1.2 com1io12CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io12CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3.1.3 com1io12CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io12CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3.1.4 com1io12CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io12CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.3.1.5 com1io12CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io12CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4 com1io12InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io12InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io12 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1 com1io12InputRegEntry OBJECT-TYPE SYNTAX Com1io12InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io12InputRegIndex } ::= { com1io12InputRegTable 1 } Com1io12InputRegEntry ::= SEQUENCE { com1io12InputRegIndex Integer32, com1io12InputRegName OCTET STRING, com1io12InputRegValue Opaque, com1io12InputRegModbusAdd Integer32, com1io12InputRegType OCTET STRING, com1io12InputRegScaleRatio Opaque, com1io12InputRegOffset Opaque, com1io12InputRegDeadband Opaque, com1io12InputRegScaleMin Opaque, com1io12InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.1 com1io12InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io12InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.2 com1io12InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io12InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.3 com1io12InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io12InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.4 com1io12InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io12InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.5 com1io12InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io12InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.6 com1io12InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io12InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.7 com1io12InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io12InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.8 com1io12InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io12InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.9 com1io12InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io12InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.4.1.10 com1io12InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io12InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5 com1io12HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io12HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io12 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1 com1io12HoldingRegEntry OBJECT-TYPE SYNTAX Com1io12HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io12HoldingRegIndex } ::= { com1io12HoldingRegTable 1 } Com1io12HoldingRegEntry ::= SEQUENCE { com1io12HoldingRegIndex Integer32, com1io12HoldingRegName OCTET STRING, com1io12HoldingRegValue Opaque, com1io12HoldingRegModbusAdd Integer32, com1io12HoldingRegType OCTET STRING, com1io12HoldingRegScaleRatio Opaque, com1io12HoldingRegOffset Opaque, com1io12HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.1 com1io12HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io12HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.2 com1io12HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io12HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.3 com1io12HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io12HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.4 com1io12HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io12HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.5 com1io12HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io12HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.6 com1io12HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io12HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.7 com1io12HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io12HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.12.5.1.8 com1io12HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io12HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13 com1io13 OBJECT IDENTIFIER ::= { com1io 13 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1 com1io13BasicInfo OBJECT IDENTIFIER ::= { com1io13 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.1 com1io13Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io13BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.2 com1io13Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io13BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.3 com1io13ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io13BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.4 com1io13ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io13BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.5 com1io13ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io13BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.6 com1io13DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io13BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.7 com1io13CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io13BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.8 com1io13InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io13BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.1.9 com1io13HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io13BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2 com1io13DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io13DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io13 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1 com1io13DiscInputEntry OBJECT-TYPE SYNTAX Com1io13DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io13DiscInputIndex } ::= { com1io13DiscInputTable 1 } Com1io13DiscInputEntry ::= SEQUENCE { com1io13DiscInputIndex Integer32, com1io13DiscInputName OCTET STRING, com1io13DiscInputValue Integer32, com1io13DiscInputModbusAdd Integer32, com1io13DiscInputCounterValue Counter32, com1io13DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1.1 com1io13DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io13DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1.2 com1io13DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io13DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1.3 com1io13DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io13DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1.4 com1io13DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io13DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1.5 com1io13DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io13DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.2.1.6 com1io13DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io13DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3 com1io13CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io13CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io13 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3.1 com1io13CoilOutputEntry OBJECT-TYPE SYNTAX Com1io13CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io13CoilOutputIndex } ::= { com1io13CoilOutputTable 1 } Com1io13CoilOutputEntry ::= SEQUENCE { com1io13CoilOutputIndex Integer32, com1io13CoilOutputName OCTET STRING, com1io13CoilOutputValue Integer32, com1io13CoilOutputModbusAdd Integer32, com1io13CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3.1.1 com1io13CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io13CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3.1.2 com1io13CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io13CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3.1.3 com1io13CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io13CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3.1.4 com1io13CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io13CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.3.1.5 com1io13CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io13CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4 com1io13InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io13InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io13 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1 com1io13InputRegEntry OBJECT-TYPE SYNTAX Com1io13InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io13InputRegIndex } ::= { com1io13InputRegTable 1 } Com1io13InputRegEntry ::= SEQUENCE { com1io13InputRegIndex Integer32, com1io13InputRegName OCTET STRING, com1io13InputRegValue Opaque, com1io13InputRegModbusAdd Integer32, com1io13InputRegType OCTET STRING, com1io13InputRegScaleRatio Opaque, com1io13InputRegOffset Opaque, com1io13InputRegDeadband Opaque, com1io13InputRegScaleMin Opaque, com1io13InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.1 com1io13InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io13InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.2 com1io13InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io13InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.3 com1io13InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io13InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.4 com1io13InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io13InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.5 com1io13InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io13InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.6 com1io13InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io13InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.7 com1io13InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io13InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.8 com1io13InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io13InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.9 com1io13InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io13InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.4.1.10 com1io13InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io13InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5 com1io13HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io13HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io13 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1 com1io13HoldingRegEntry OBJECT-TYPE SYNTAX Com1io13HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io13HoldingRegIndex } ::= { com1io13HoldingRegTable 1 } Com1io13HoldingRegEntry ::= SEQUENCE { com1io13HoldingRegIndex Integer32, com1io13HoldingRegName OCTET STRING, com1io13HoldingRegValue Opaque, com1io13HoldingRegModbusAdd Integer32, com1io13HoldingRegType OCTET STRING, com1io13HoldingRegScaleRatio Opaque, com1io13HoldingRegOffset Opaque, com1io13HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.1 com1io13HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io13HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.2 com1io13HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io13HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.3 com1io13HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io13HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.4 com1io13HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io13HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.5 com1io13HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io13HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.6 com1io13HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io13HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.7 com1io13HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io13HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.13.5.1.8 com1io13HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io13HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14 com1io14 OBJECT IDENTIFIER ::= { com1io 14 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1 com1io14BasicInfo OBJECT IDENTIFIER ::= { com1io14 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.1 com1io14Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io14BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.2 com1io14Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io14BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.3 com1io14ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io14BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.4 com1io14ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io14BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.5 com1io14ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io14BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.6 com1io14DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io14BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.7 com1io14CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io14BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.8 com1io14InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io14BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.1.9 com1io14HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io14BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2 com1io14DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io14DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io14 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1 com1io14DiscInputEntry OBJECT-TYPE SYNTAX Com1io14DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io14DiscInputIndex } ::= { com1io14DiscInputTable 1 } Com1io14DiscInputEntry ::= SEQUENCE { com1io14DiscInputIndex Integer32, com1io14DiscInputName OCTET STRING, com1io14DiscInputValue Integer32, com1io14DiscInputModbusAdd Integer32, com1io14DiscInputCounterValue Counter32, com1io14DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1.1 com1io14DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io14DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1.2 com1io14DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io14DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1.3 com1io14DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io14DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1.4 com1io14DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io14DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1.5 com1io14DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io14DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.2.1.6 com1io14DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io14DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3 com1io14CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io14CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io14 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3.1 com1io14CoilOutputEntry OBJECT-TYPE SYNTAX Com1io14CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io14CoilOutputIndex } ::= { com1io14CoilOutputTable 1 } Com1io14CoilOutputEntry ::= SEQUENCE { com1io14CoilOutputIndex Integer32, com1io14CoilOutputName OCTET STRING, com1io14CoilOutputValue Integer32, com1io14CoilOutputModbusAdd Integer32, com1io14CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3.1.1 com1io14CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io14CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3.1.2 com1io14CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io14CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3.1.3 com1io14CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io14CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3.1.4 com1io14CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io14CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.3.1.5 com1io14CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io14CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4 com1io14InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io14InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io14 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1 com1io14InputRegEntry OBJECT-TYPE SYNTAX Com1io14InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io14InputRegIndex } ::= { com1io14InputRegTable 1 } Com1io14InputRegEntry ::= SEQUENCE { com1io14InputRegIndex Integer32, com1io14InputRegName OCTET STRING, com1io14InputRegValue Opaque, com1io14InputRegModbusAdd Integer32, com1io14InputRegType OCTET STRING, com1io14InputRegScaleRatio Opaque, com1io14InputRegOffset Opaque, com1io14InputRegDeadband Opaque, com1io14InputRegScaleMin Opaque, com1io14InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.1 com1io14InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io14InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.2 com1io14InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io14InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.3 com1io14InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io14InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.4 com1io14InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io14InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.5 com1io14InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io14InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.6 com1io14InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io14InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.7 com1io14InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io14InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.8 com1io14InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io14InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.9 com1io14InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io14InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.4.1.10 com1io14InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io14InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5 com1io14HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io14HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io14 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1 com1io14HoldingRegEntry OBJECT-TYPE SYNTAX Com1io14HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io14HoldingRegIndex } ::= { com1io14HoldingRegTable 1 } Com1io14HoldingRegEntry ::= SEQUENCE { com1io14HoldingRegIndex Integer32, com1io14HoldingRegName OCTET STRING, com1io14HoldingRegValue Opaque, com1io14HoldingRegModbusAdd Integer32, com1io14HoldingRegType OCTET STRING, com1io14HoldingRegScaleRatio Opaque, com1io14HoldingRegOffset Opaque, com1io14HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.1 com1io14HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io14HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.2 com1io14HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io14HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.3 com1io14HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io14HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.4 com1io14HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io14HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.5 com1io14HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io14HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.6 com1io14HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io14HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.7 com1io14HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io14HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.14.5.1.8 com1io14HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io14HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15 com1io15 OBJECT IDENTIFIER ::= { com1io 15 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1 com1io15BasicInfo OBJECT IDENTIFIER ::= { com1io15 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.1 com1io15Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io15BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.2 com1io15Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io15BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.3 com1io15ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io15BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.4 com1io15ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io15BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.5 com1io15ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io15BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.6 com1io15DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io15BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.7 com1io15CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io15BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.8 com1io15InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io15BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.1.9 com1io15HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io15BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2 com1io15DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io15DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io15 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1 com1io15DiscInputEntry OBJECT-TYPE SYNTAX Com1io15DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io15DiscInputIndex } ::= { com1io15DiscInputTable 1 } Com1io15DiscInputEntry ::= SEQUENCE { com1io15DiscInputIndex Integer32, com1io15DiscInputName OCTET STRING, com1io15DiscInputValue Integer32, com1io15DiscInputModbusAdd Integer32, com1io15DiscInputCounterValue Counter32, com1io15DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1.1 com1io15DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io15DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1.2 com1io15DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io15DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1.3 com1io15DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io15DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1.4 com1io15DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io15DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1.5 com1io15DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io15DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.2.1.6 com1io15DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io15DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3 com1io15CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io15CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io15 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3.1 com1io15CoilOutputEntry OBJECT-TYPE SYNTAX Com1io15CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io15CoilOutputIndex } ::= { com1io15CoilOutputTable 1 } Com1io15CoilOutputEntry ::= SEQUENCE { com1io15CoilOutputIndex Integer32, com1io15CoilOutputName OCTET STRING, com1io15CoilOutputValue Integer32, com1io15CoilOutputModbusAdd Integer32, com1io15CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3.1.1 com1io15CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io15CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3.1.2 com1io15CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io15CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3.1.3 com1io15CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io15CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3.1.4 com1io15CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io15CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.3.1.5 com1io15CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io15CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4 com1io15InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io15InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io15 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1 com1io15InputRegEntry OBJECT-TYPE SYNTAX Com1io15InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io15InputRegIndex } ::= { com1io15InputRegTable 1 } Com1io15InputRegEntry ::= SEQUENCE { com1io15InputRegIndex Integer32, com1io15InputRegName OCTET STRING, com1io15InputRegValue Opaque, com1io15InputRegModbusAdd Integer32, com1io15InputRegType OCTET STRING, com1io15InputRegScaleRatio Opaque, com1io15InputRegOffset Opaque, com1io15InputRegDeadband Opaque, com1io15InputRegScaleMin Opaque, com1io15InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.1 com1io15InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io15InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.2 com1io15InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io15InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.3 com1io15InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io15InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.4 com1io15InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io15InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.5 com1io15InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io15InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.6 com1io15InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io15InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.7 com1io15InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io15InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.8 com1io15InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io15InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.9 com1io15InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io15InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.4.1.10 com1io15InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io15InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5 com1io15HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io15HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io15 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1 com1io15HoldingRegEntry OBJECT-TYPE SYNTAX Com1io15HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io15HoldingRegIndex } ::= { com1io15HoldingRegTable 1 } Com1io15HoldingRegEntry ::= SEQUENCE { com1io15HoldingRegIndex Integer32, com1io15HoldingRegName OCTET STRING, com1io15HoldingRegValue Opaque, com1io15HoldingRegModbusAdd Integer32, com1io15HoldingRegType OCTET STRING, com1io15HoldingRegScaleRatio Opaque, com1io15HoldingRegOffset Opaque, com1io15HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.1 com1io15HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io15HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.2 com1io15HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io15HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.3 com1io15HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io15HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.4 com1io15HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io15HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.5 com1io15HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io15HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.6 com1io15HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io15HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.7 com1io15HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io15HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.15.5.1.8 com1io15HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io15HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16 com1io16 OBJECT IDENTIFIER ::= { com1io 16 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1 com1io16BasicInfo OBJECT IDENTIFIER ::= { com1io16 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.1 com1io16Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com1io16BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.2 com1io16Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com1io16BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.3 com1io16ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com1io16BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.4 com1io16ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com1io16BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.5 com1io16ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com1io16BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.6 com1io16DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com1io16BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.7 com1io16CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com1io16BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.8 com1io16InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com1io16BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.1.9 com1io16HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com1io16BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2 com1io16DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io16DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io16 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1 com1io16DiscInputEntry OBJECT-TYPE SYNTAX Com1io16DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com1io16DiscInputIndex } ::= { com1io16DiscInputTable 1 } Com1io16DiscInputEntry ::= SEQUENCE { com1io16DiscInputIndex Integer32, com1io16DiscInputName OCTET STRING, com1io16DiscInputValue Integer32, com1io16DiscInputModbusAdd Integer32, com1io16DiscInputCounterValue Counter32, com1io16DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1.1 com1io16DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com1io16DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1.2 com1io16DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com1io16DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1.3 com1io16DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com1io16DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1.4 com1io16DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com1io16DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1.5 com1io16DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com1io16DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.2.1.6 com1io16DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com1io16DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3 com1io16CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io16CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com1io16 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3.1 com1io16CoilOutputEntry OBJECT-TYPE SYNTAX Com1io16CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com1io16CoilOutputIndex } ::= { com1io16CoilOutputTable 1 } Com1io16CoilOutputEntry ::= SEQUENCE { com1io16CoilOutputIndex Integer32, com1io16CoilOutputName OCTET STRING, com1io16CoilOutputValue Integer32, com1io16CoilOutputModbusAdd Integer32, com1io16CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3.1.1 com1io16CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com1io16CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3.1.2 com1io16CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com1io16CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3.1.3 com1io16CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com1io16CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3.1.4 com1io16CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com1io16CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.3.1.5 com1io16CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com1io16CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4 com1io16InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io16InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com1io16 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1 com1io16InputRegEntry OBJECT-TYPE SYNTAX Com1io16InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io16InputRegIndex } ::= { com1io16InputRegTable 1 } Com1io16InputRegEntry ::= SEQUENCE { com1io16InputRegIndex Integer32, com1io16InputRegName OCTET STRING, com1io16InputRegValue Opaque, com1io16InputRegModbusAdd Integer32, com1io16InputRegType OCTET STRING, com1io16InputRegScaleRatio Opaque, com1io16InputRegOffset Opaque, com1io16InputRegDeadband Opaque, com1io16InputRegScaleMin Opaque, com1io16InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.1 com1io16InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com1io16InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.2 com1io16InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com1io16InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.3 com1io16InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com1io16InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.4 com1io16InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com1io16InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.5 com1io16InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com1io16InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.6 com1io16InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io16InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.7 com1io16InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com1io16InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.8 com1io16InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com1io16InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.9 com1io16InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io16InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.4.1.10 com1io16InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com1io16InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5 com1io16HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com1io16HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com1io16 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1 com1io16HoldingRegEntry OBJECT-TYPE SYNTAX Com1io16HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com1io16HoldingRegIndex } ::= { com1io16HoldingRegTable 1 } Com1io16HoldingRegEntry ::= SEQUENCE { com1io16HoldingRegIndex Integer32, com1io16HoldingRegName OCTET STRING, com1io16HoldingRegValue Opaque, com1io16HoldingRegModbusAdd Integer32, com1io16HoldingRegType OCTET STRING, com1io16HoldingRegScaleRatio Opaque, com1io16HoldingRegOffset Opaque, com1io16HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.1 com1io16HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com1io16HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.2 com1io16HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com1io16HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.3 com1io16HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com1io16HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.4 com1io16HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com1io16HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.5 com1io16HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com1io16HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.6 com1io16HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io16HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.7 com1io16HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com1io16HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.1.16.5.1.8 com1io16HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com1io16HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2 com2io OBJECT IDENTIFIER ::= { ioModuleInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1 com2io1 OBJECT IDENTIFIER ::= { com2io 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1 com2io1BasicInfo OBJECT IDENTIFIER ::= { com2io1 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.1 com2io1Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io1BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.2 com2io1Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io1BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.3 com2io1ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io1BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.4 com2io1ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io1BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.5 com2io1ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io1BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.6 com2io1DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io1BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.7 com2io1CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io1BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.8 com2io1InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io1BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.1.9 com2io1HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io1BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2 com2io1DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io1DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io1 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1 com2io1DiscInputEntry OBJECT-TYPE SYNTAX Com2io1DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io1DiscInputIndex } ::= { com2io1DiscInputTable 1 } Com2io1DiscInputEntry ::= SEQUENCE { com2io1DiscInputIndex Integer32, com2io1DiscInputName OCTET STRING, com2io1DiscInputValue Integer32, com2io1DiscInputModbusAdd Integer32, com2io1DiscInputCounterValue Counter32, com2io1DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1.1 com2io1DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io1DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1.2 com2io1DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io1DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1.3 com2io1DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io1DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1.4 com2io1DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io1DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1.5 com2io1DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io1DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.2.1.6 com2io1DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io1DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3 com2io1CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io1CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io1 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3.1 com2io1CoilOutputEntry OBJECT-TYPE SYNTAX Com2io1CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io1CoilOutputIndex } ::= { com2io1CoilOutputTable 1 } Com2io1CoilOutputEntry ::= SEQUENCE { com2io1CoilOutputIndex Integer32, com2io1CoilOutputName OCTET STRING, com2io1CoilOutputValue Integer32, com2io1CoilOutputModbusAdd Integer32, com2io1CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3.1.1 com2io1CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io1CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3.1.2 com2io1CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io1CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3.1.3 com2io1CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io1CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3.1.4 com2io1CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io1CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.3.1.5 com2io1CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io1CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4 com2io1InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io1InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io1 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1 com2io1InputRegEntry OBJECT-TYPE SYNTAX Com2io1InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io1InputRegIndex } ::= { com2io1InputRegTable 1 } Com2io1InputRegEntry ::= SEQUENCE { com2io1InputRegIndex Integer32, com2io1InputRegName OCTET STRING, com2io1InputRegValue Opaque, com2io1InputRegModbusAdd Integer32, com2io1InputRegType OCTET STRING, com2io1InputRegScaleRatio Opaque, com2io1InputRegOffset Opaque, com2io1InputRegDeadband Opaque, com2io1InputRegScaleMin Opaque, com2io1InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.1 com2io1InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io1InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.2 com2io1InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io1InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.3 com2io1InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io1InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.4 com2io1InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io1InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.5 com2io1InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io1InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.6 com2io1InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io1InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.7 com2io1InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io1InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.8 com2io1InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io1InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.9 com2io1InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io1InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.4.1.10 com2io1InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io1InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5 com2io1HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io1HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io1 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1 com2io1HoldingRegEntry OBJECT-TYPE SYNTAX Com2io1HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io1HoldingRegIndex } ::= { com2io1HoldingRegTable 1 } Com2io1HoldingRegEntry ::= SEQUENCE { com2io1HoldingRegIndex Integer32, com2io1HoldingRegName OCTET STRING, com2io1HoldingRegValue Opaque, com2io1HoldingRegModbusAdd Integer32, com2io1HoldingRegType OCTET STRING, com2io1HoldingRegScaleRatio Opaque, com2io1HoldingRegOffset Opaque, com2io1HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.1 com2io1HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io1HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.2 com2io1HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io1HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.3 com2io1HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io1HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.4 com2io1HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io1HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.5 com2io1HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io1HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.6 com2io1HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io1HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.7 com2io1HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io1HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.1.5.1.8 com2io1HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io1HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2 com2io2 OBJECT IDENTIFIER ::= { com2io 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1 com2io2BasicInfo OBJECT IDENTIFIER ::= { com2io2 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.1 com2io2Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io2BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.2 com2io2Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io2BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.3 com2io2ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io2BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.4 com2io2ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io2BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.5 com2io2ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io2BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.6 com2io2DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io2BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.7 com2io2CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io2BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.8 com2io2InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io2BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.1.9 com2io2HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io2BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2 com2io2DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io2DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io2 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1 com2io2DiscInputEntry OBJECT-TYPE SYNTAX Com2io2DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io2DiscInputIndex } ::= { com2io2DiscInputTable 1 } Com2io2DiscInputEntry ::= SEQUENCE { com2io2DiscInputIndex Integer32, com2io2DiscInputName OCTET STRING, com2io2DiscInputValue Integer32, com2io2DiscInputModbusAdd Integer32, com2io2DiscInputCounterValue Counter32, com2io2DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1.1 com2io2DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io2DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1.2 com2io2DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io2DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1.3 com2io2DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io2DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1.4 com2io2DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io2DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1.5 com2io2DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io2DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.2.1.6 com2io2DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io2DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3 com2io2CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io2CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io2 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3.1 com2io2CoilOutputEntry OBJECT-TYPE SYNTAX Com2io2CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io2CoilOutputIndex } ::= { com2io2CoilOutputTable 1 } Com2io2CoilOutputEntry ::= SEQUENCE { com2io2CoilOutputIndex Integer32, com2io2CoilOutputName OCTET STRING, com2io2CoilOutputValue Integer32, com2io2CoilOutputModbusAdd Integer32, com2io2CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3.1.1 com2io2CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io2CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3.1.2 com2io2CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io2CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3.1.3 com2io2CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io2CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3.1.4 com2io2CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io2CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.3.1.5 com2io2CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io2CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4 com2io2InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io2InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io2 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1 com2io2InputRegEntry OBJECT-TYPE SYNTAX Com2io2InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io2InputRegIndex } ::= { com2io2InputRegTable 1 } Com2io2InputRegEntry ::= SEQUENCE { com2io2InputRegIndex Integer32, com2io2InputRegName OCTET STRING, com2io2InputRegValue Opaque, com2io2InputRegModbusAdd Integer32, com2io2InputRegType OCTET STRING, com2io2InputRegScaleRatio Opaque, com2io2InputRegOffset Opaque, com2io2InputRegDeadband Opaque, com2io2InputRegScaleMin Opaque, com2io2InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.1 com2io2InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io2InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.2 com2io2InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io2InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.3 com2io2InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io2InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.4 com2io2InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io2InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.5 com2io2InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io2InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.6 com2io2InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io2InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.7 com2io2InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io2InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.8 com2io2InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io2InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.9 com2io2InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io2InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.4.1.10 com2io2InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io2InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5 com2io2HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io2HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io2 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1 com2io2HoldingRegEntry OBJECT-TYPE SYNTAX Com2io2HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io2HoldingRegIndex } ::= { com2io2HoldingRegTable 1 } Com2io2HoldingRegEntry ::= SEQUENCE { com2io2HoldingRegIndex Integer32, com2io2HoldingRegName OCTET STRING, com2io2HoldingRegValue Opaque, com2io2HoldingRegModbusAdd Integer32, com2io2HoldingRegType OCTET STRING, com2io2HoldingRegScaleRatio Opaque, com2io2HoldingRegOffset Opaque, com2io2HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.1 com2io2HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io2HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.2 com2io2HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io2HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.3 com2io2HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io2HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.4 com2io2HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io2HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.5 com2io2HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io2HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.6 com2io2HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io2HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.7 com2io2HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io2HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.2.5.1.8 com2io2HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io2HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3 com2io3 OBJECT IDENTIFIER ::= { com2io 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1 com2io3BasicInfo OBJECT IDENTIFIER ::= { com2io3 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.1 com2io3Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io3BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.2 com2io3Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io3BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.3 com2io3ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io3BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.4 com2io3ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io3BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.5 com2io3ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io3BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.6 com2io3DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io3BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.7 com2io3CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io3BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.8 com2io3InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io3BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.1.9 com2io3HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io3BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2 com2io3DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io3DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io3 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1 com2io3DiscInputEntry OBJECT-TYPE SYNTAX Com2io3DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io3DiscInputIndex } ::= { com2io3DiscInputTable 1 } Com2io3DiscInputEntry ::= SEQUENCE { com2io3DiscInputIndex Integer32, com2io3DiscInputName OCTET STRING, com2io3DiscInputValue Integer32, com2io3DiscInputModbusAdd Integer32, com2io3DiscInputCounterValue Counter32, com2io3DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1.1 com2io3DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io3DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1.2 com2io3DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io3DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1.3 com2io3DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io3DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1.4 com2io3DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io3DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1.5 com2io3DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io3DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.2.1.6 com2io3DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io3DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3 com2io3CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io3CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io3 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3.1 com2io3CoilOutputEntry OBJECT-TYPE SYNTAX Com2io3CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io3CoilOutputIndex } ::= { com2io3CoilOutputTable 1 } Com2io3CoilOutputEntry ::= SEQUENCE { com2io3CoilOutputIndex Integer32, com2io3CoilOutputName OCTET STRING, com2io3CoilOutputValue Integer32, com2io3CoilOutputModbusAdd Integer32, com2io3CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3.1.1 com2io3CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io3CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3.1.2 com2io3CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io3CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3.1.3 com2io3CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io3CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3.1.4 com2io3CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io3CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.3.1.5 com2io3CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io3CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4 com2io3InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io3InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io3 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1 com2io3InputRegEntry OBJECT-TYPE SYNTAX Com2io3InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io3InputRegIndex } ::= { com2io3InputRegTable 1 } Com2io3InputRegEntry ::= SEQUENCE { com2io3InputRegIndex Integer32, com2io3InputRegName OCTET STRING, com2io3InputRegValue Opaque, com2io3InputRegModbusAdd Integer32, com2io3InputRegType OCTET STRING, com2io3InputRegScaleRatio Opaque, com2io3InputRegOffset Opaque, com2io3InputRegDeadband Opaque, com2io3InputRegScaleMin Opaque, com2io3InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.1 com2io3InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io3InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.2 com2io3InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io3InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.3 com2io3InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io3InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.4 com2io3InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io3InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.5 com2io3InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io3InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.6 com2io3InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io3InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.7 com2io3InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io3InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.8 com2io3InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io3InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.9 com2io3InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io3InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.4.1.10 com2io3InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io3InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5 com2io3HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io3HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io3 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1 com2io3HoldingRegEntry OBJECT-TYPE SYNTAX Com2io3HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io3HoldingRegIndex } ::= { com2io3HoldingRegTable 1 } Com2io3HoldingRegEntry ::= SEQUENCE { com2io3HoldingRegIndex Integer32, com2io3HoldingRegName OCTET STRING, com2io3HoldingRegValue Opaque, com2io3HoldingRegModbusAdd Integer32, com2io3HoldingRegType OCTET STRING, com2io3HoldingRegScaleRatio Opaque, com2io3HoldingRegOffset Opaque, com2io3HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.1 com2io3HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io3HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.2 com2io3HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io3HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.3 com2io3HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io3HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.4 com2io3HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io3HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.5 com2io3HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io3HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.6 com2io3HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io3HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.7 com2io3HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io3HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.3.5.1.8 com2io3HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io3HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4 com2io4 OBJECT IDENTIFIER ::= { com2io 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1 com2io4BasicInfo OBJECT IDENTIFIER ::= { com2io4 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.1 com2io4Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io4BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.2 com2io4Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io4BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.3 com2io4ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io4BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.4 com2io4ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io4BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.5 com2io4ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io4BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.6 com2io4DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io4BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.7 com2io4CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io4BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.8 com2io4InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io4BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.1.9 com2io4HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io4BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2 com2io4DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io4DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io4 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1 com2io4DiscInputEntry OBJECT-TYPE SYNTAX Com2io4DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io4DiscInputIndex } ::= { com2io4DiscInputTable 1 } Com2io4DiscInputEntry ::= SEQUENCE { com2io4DiscInputIndex Integer32, com2io4DiscInputName OCTET STRING, com2io4DiscInputValue Integer32, com2io4DiscInputModbusAdd Integer32, com2io4DiscInputCounterValue Counter32, com2io4DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1.1 com2io4DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io4DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1.2 com2io4DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io4DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1.3 com2io4DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io4DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1.4 com2io4DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io4DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1.5 com2io4DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io4DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.2.1.6 com2io4DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io4DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3 com2io4CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io4CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io4 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3.1 com2io4CoilOutputEntry OBJECT-TYPE SYNTAX Com2io4CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io4CoilOutputIndex } ::= { com2io4CoilOutputTable 1 } Com2io4CoilOutputEntry ::= SEQUENCE { com2io4CoilOutputIndex Integer32, com2io4CoilOutputName OCTET STRING, com2io4CoilOutputValue Integer32, com2io4CoilOutputModbusAdd Integer32, com2io4CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3.1.1 com2io4CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io4CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3.1.2 com2io4CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io4CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3.1.3 com2io4CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io4CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3.1.4 com2io4CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io4CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.3.1.5 com2io4CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io4CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4 com2io4InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io4InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io4 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1 com2io4InputRegEntry OBJECT-TYPE SYNTAX Com2io4InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io4InputRegIndex } ::= { com2io4InputRegTable 1 } Com2io4InputRegEntry ::= SEQUENCE { com2io4InputRegIndex Integer32, com2io4InputRegName OCTET STRING, com2io4InputRegValue Opaque, com2io4InputRegModbusAdd Integer32, com2io4InputRegType OCTET STRING, com2io4InputRegScaleRatio Opaque, com2io4InputRegOffset Opaque, com2io4InputRegDeadband Opaque, com2io4InputRegScaleMin Opaque, com2io4InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.1 com2io4InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io4InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.2 com2io4InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io4InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.3 com2io4InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io4InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.4 com2io4InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io4InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.5 com2io4InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io4InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.6 com2io4InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io4InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.7 com2io4InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io4InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.8 com2io4InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io4InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.9 com2io4InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io4InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.4.1.10 com2io4InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io4InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5 com2io4HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io4HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io4 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1 com2io4HoldingRegEntry OBJECT-TYPE SYNTAX Com2io4HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io4HoldingRegIndex } ::= { com2io4HoldingRegTable 1 } Com2io4HoldingRegEntry ::= SEQUENCE { com2io4HoldingRegIndex Integer32, com2io4HoldingRegName OCTET STRING, com2io4HoldingRegValue Opaque, com2io4HoldingRegModbusAdd Integer32, com2io4HoldingRegType OCTET STRING, com2io4HoldingRegScaleRatio Opaque, com2io4HoldingRegOffset Opaque, com2io4HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.1 com2io4HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io4HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.2 com2io4HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io4HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.3 com2io4HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io4HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.4 com2io4HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io4HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.5 com2io4HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io4HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.6 com2io4HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io4HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.7 com2io4HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io4HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.4.5.1.8 com2io4HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io4HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5 com2io5 OBJECT IDENTIFIER ::= { com2io 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1 com2io5BasicInfo OBJECT IDENTIFIER ::= { com2io5 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.1 com2io5Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io5BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.2 com2io5Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io5BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.3 com2io5ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io5BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.4 com2io5ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io5BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.5 com2io5ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io5BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.6 com2io5DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io5BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.7 com2io5CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io5BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.8 com2io5InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io5BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.1.9 com2io5HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io5BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2 com2io5DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io5DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io5 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1 com2io5DiscInputEntry OBJECT-TYPE SYNTAX Com2io5DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io5DiscInputIndex } ::= { com2io5DiscInputTable 1 } Com2io5DiscInputEntry ::= SEQUENCE { com2io5DiscInputIndex Integer32, com2io5DiscInputName OCTET STRING, com2io5DiscInputValue Integer32, com2io5DiscInputModbusAdd Integer32, com2io5DiscInputCounterValue Counter32, com2io5DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1.1 com2io5DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io5DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1.2 com2io5DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io5DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1.3 com2io5DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io5DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1.4 com2io5DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io5DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1.5 com2io5DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io5DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.2.1.6 com2io5DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io5DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3 com2io5CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io5CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io5 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3.1 com2io5CoilOutputEntry OBJECT-TYPE SYNTAX Com2io5CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io5CoilOutputIndex } ::= { com2io5CoilOutputTable 1 } Com2io5CoilOutputEntry ::= SEQUENCE { com2io5CoilOutputIndex Integer32, com2io5CoilOutputName OCTET STRING, com2io5CoilOutputValue Integer32, com2io5CoilOutputModbusAdd Integer32, com2io5CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3.1.1 com2io5CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io5CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3.1.2 com2io5CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io5CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3.1.3 com2io5CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io5CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3.1.4 com2io5CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io5CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.3.1.5 com2io5CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io5CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4 com2io5InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io5InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io5 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1 com2io5InputRegEntry OBJECT-TYPE SYNTAX Com2io5InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io5InputRegIndex } ::= { com2io5InputRegTable 1 } Com2io5InputRegEntry ::= SEQUENCE { com2io5InputRegIndex Integer32, com2io5InputRegName OCTET STRING, com2io5InputRegValue Opaque, com2io5InputRegModbusAdd Integer32, com2io5InputRegType OCTET STRING, com2io5InputRegScaleRatio Opaque, com2io5InputRegOffset Opaque, com2io5InputRegDeadband Opaque, com2io5InputRegScaleMin Opaque, com2io5InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.1 com2io5InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io5InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.2 com2io5InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io5InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.3 com2io5InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io5InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.4 com2io5InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io5InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.5 com2io5InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io5InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.6 com2io5InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io5InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.7 com2io5InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io5InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.8 com2io5InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io5InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.9 com2io5InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io5InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.4.1.10 com2io5InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io5InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5 com2io5HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io5HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io5 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1 com2io5HoldingRegEntry OBJECT-TYPE SYNTAX Com2io5HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io5HoldingRegIndex } ::= { com2io5HoldingRegTable 1 } Com2io5HoldingRegEntry ::= SEQUENCE { com2io5HoldingRegIndex Integer32, com2io5HoldingRegName OCTET STRING, com2io5HoldingRegValue Opaque, com2io5HoldingRegModbusAdd Integer32, com2io5HoldingRegType OCTET STRING, com2io5HoldingRegScaleRatio Opaque, com2io5HoldingRegOffset Opaque, com2io5HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.1 com2io5HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io5HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.2 com2io5HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io5HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.3 com2io5HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io5HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.4 com2io5HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io5HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.5 com2io5HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io5HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.6 com2io5HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io5HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.7 com2io5HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io5HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.5.5.1.8 com2io5HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io5HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6 com2io6 OBJECT IDENTIFIER ::= { com2io 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1 com2io6BasicInfo OBJECT IDENTIFIER ::= { com2io6 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.1 com2io6Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io6BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.2 com2io6Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io6BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.3 com2io6ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io6BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.4 com2io6ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io6BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.5 com2io6ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io6BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.6 com2io6DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io6BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.7 com2io6CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io6BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.8 com2io6InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io6BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.1.9 com2io6HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io6BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2 com2io6DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io6DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io6 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1 com2io6DiscInputEntry OBJECT-TYPE SYNTAX Com2io6DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io6DiscInputIndex } ::= { com2io6DiscInputTable 1 } Com2io6DiscInputEntry ::= SEQUENCE { com2io6DiscInputIndex Integer32, com2io6DiscInputName OCTET STRING, com2io6DiscInputValue Integer32, com2io6DiscInputModbusAdd Integer32, com2io6DiscInputCounterValue Counter32, com2io6DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1.1 com2io6DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io6DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1.2 com2io6DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io6DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1.3 com2io6DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io6DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1.4 com2io6DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io6DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1.5 com2io6DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io6DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.2.1.6 com2io6DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io6DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3 com2io6CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io6CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io6 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3.1 com2io6CoilOutputEntry OBJECT-TYPE SYNTAX Com2io6CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io6CoilOutputIndex } ::= { com2io6CoilOutputTable 1 } Com2io6CoilOutputEntry ::= SEQUENCE { com2io6CoilOutputIndex Integer32, com2io6CoilOutputName OCTET STRING, com2io6CoilOutputValue Integer32, com2io6CoilOutputModbusAdd Integer32, com2io6CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3.1.1 com2io6CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io6CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3.1.2 com2io6CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io6CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3.1.3 com2io6CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io6CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3.1.4 com2io6CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io6CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.3.1.5 com2io6CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io6CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4 com2io6InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io6InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io6 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1 com2io6InputRegEntry OBJECT-TYPE SYNTAX Com2io6InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io6InputRegIndex } ::= { com2io6InputRegTable 1 } Com2io6InputRegEntry ::= SEQUENCE { com2io6InputRegIndex Integer32, com2io6InputRegName OCTET STRING, com2io6InputRegValue Opaque, com2io6InputRegModbusAdd Integer32, com2io6InputRegType OCTET STRING, com2io6InputRegScaleRatio Opaque, com2io6InputRegOffset Opaque, com2io6InputRegDeadband Opaque, com2io6InputRegScaleMin Opaque, com2io6InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.1 com2io6InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io6InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.2 com2io6InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io6InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.3 com2io6InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io6InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.4 com2io6InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io6InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.5 com2io6InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io6InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.6 com2io6InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io6InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.7 com2io6InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io6InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.8 com2io6InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io6InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.9 com2io6InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io6InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.4.1.10 com2io6InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io6InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5 com2io6HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io6HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io6 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1 com2io6HoldingRegEntry OBJECT-TYPE SYNTAX Com2io6HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io6HoldingRegIndex } ::= { com2io6HoldingRegTable 1 } Com2io6HoldingRegEntry ::= SEQUENCE { com2io6HoldingRegIndex Integer32, com2io6HoldingRegName OCTET STRING, com2io6HoldingRegValue Opaque, com2io6HoldingRegModbusAdd Integer32, com2io6HoldingRegType OCTET STRING, com2io6HoldingRegScaleRatio Opaque, com2io6HoldingRegOffset Opaque, com2io6HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.1 com2io6HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io6HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.2 com2io6HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io6HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.3 com2io6HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io6HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.4 com2io6HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io6HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.5 com2io6HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io6HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.6 com2io6HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io6HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.7 com2io6HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io6HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.6.5.1.8 com2io6HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io6HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7 com2io7 OBJECT IDENTIFIER ::= { com2io 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1 com2io7BasicInfo OBJECT IDENTIFIER ::= { com2io7 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.1 com2io7Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io7BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.2 com2io7Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io7BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.3 com2io7ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io7BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.4 com2io7ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io7BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.5 com2io7ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io7BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.6 com2io7DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io7BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.7 com2io7CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io7BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.8 com2io7InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io7BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.1.9 com2io7HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io7BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2 com2io7DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io7DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io7 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1 com2io7DiscInputEntry OBJECT-TYPE SYNTAX Com2io7DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io7DiscInputIndex } ::= { com2io7DiscInputTable 1 } Com2io7DiscInputEntry ::= SEQUENCE { com2io7DiscInputIndex Integer32, com2io7DiscInputName OCTET STRING, com2io7DiscInputValue Integer32, com2io7DiscInputModbusAdd Integer32, com2io7DiscInputCounterValue Counter32, com2io7DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1.1 com2io7DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io7DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1.2 com2io7DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io7DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1.3 com2io7DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io7DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1.4 com2io7DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io7DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1.5 com2io7DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io7DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.2.1.6 com2io7DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io7DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3 com2io7CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io7CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io7 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3.1 com2io7CoilOutputEntry OBJECT-TYPE SYNTAX Com2io7CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io7CoilOutputIndex } ::= { com2io7CoilOutputTable 1 } Com2io7CoilOutputEntry ::= SEQUENCE { com2io7CoilOutputIndex Integer32, com2io7CoilOutputName OCTET STRING, com2io7CoilOutputValue Integer32, com2io7CoilOutputModbusAdd Integer32, com2io7CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3.1.1 com2io7CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io7CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3.1.2 com2io7CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io7CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3.1.3 com2io7CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io7CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3.1.4 com2io7CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io7CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.3.1.5 com2io7CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io7CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4 com2io7InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io7InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io7 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1 com2io7InputRegEntry OBJECT-TYPE SYNTAX Com2io7InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io7InputRegIndex } ::= { com2io7InputRegTable 1 } Com2io7InputRegEntry ::= SEQUENCE { com2io7InputRegIndex Integer32, com2io7InputRegName OCTET STRING, com2io7InputRegValue Opaque, com2io7InputRegModbusAdd Integer32, com2io7InputRegType OCTET STRING, com2io7InputRegScaleRatio Opaque, com2io7InputRegOffset Opaque, com2io7InputRegDeadband Opaque, com2io7InputRegScaleMin Opaque, com2io7InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.1 com2io7InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io7InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.2 com2io7InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io7InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.3 com2io7InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io7InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.4 com2io7InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io7InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.5 com2io7InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io7InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.6 com2io7InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io7InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.7 com2io7InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io7InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.8 com2io7InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io7InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.9 com2io7InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io7InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.4.1.10 com2io7InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io7InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5 com2io7HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io7HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io7 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1 com2io7HoldingRegEntry OBJECT-TYPE SYNTAX Com2io7HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io7HoldingRegIndex } ::= { com2io7HoldingRegTable 1 } Com2io7HoldingRegEntry ::= SEQUENCE { com2io7HoldingRegIndex Integer32, com2io7HoldingRegName OCTET STRING, com2io7HoldingRegValue Opaque, com2io7HoldingRegModbusAdd Integer32, com2io7HoldingRegType OCTET STRING, com2io7HoldingRegScaleRatio Opaque, com2io7HoldingRegOffset Opaque, com2io7HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.1 com2io7HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io7HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.2 com2io7HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io7HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.3 com2io7HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io7HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.4 com2io7HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io7HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.5 com2io7HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io7HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.6 com2io7HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io7HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.7 com2io7HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io7HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.7.5.1.8 com2io7HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io7HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8 com2io8 OBJECT IDENTIFIER ::= { com2io 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1 com2io8BasicInfo OBJECT IDENTIFIER ::= { com2io8 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.1 com2io8Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io8BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.2 com2io8Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io8BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.3 com2io8ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io8BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.4 com2io8ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io8BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.5 com2io8ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io8BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.6 com2io8DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io8BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.7 com2io8CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io8BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.8 com2io8InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io8BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.1.9 com2io8HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io8BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2 com2io8DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io8DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io8 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1 com2io8DiscInputEntry OBJECT-TYPE SYNTAX Com2io8DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io8DiscInputIndex } ::= { com2io8DiscInputTable 1 } Com2io8DiscInputEntry ::= SEQUENCE { com2io8DiscInputIndex Integer32, com2io8DiscInputName OCTET STRING, com2io8DiscInputValue Integer32, com2io8DiscInputModbusAdd Integer32, com2io8DiscInputCounterValue Counter32, com2io8DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1.1 com2io8DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io8DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1.2 com2io8DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io8DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1.3 com2io8DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io8DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1.4 com2io8DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io8DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1.5 com2io8DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io8DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.2.1.6 com2io8DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io8DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3 com2io8CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io8CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io8 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3.1 com2io8CoilOutputEntry OBJECT-TYPE SYNTAX Com2io8CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io8CoilOutputIndex } ::= { com2io8CoilOutputTable 1 } Com2io8CoilOutputEntry ::= SEQUENCE { com2io8CoilOutputIndex Integer32, com2io8CoilOutputName OCTET STRING, com2io8CoilOutputValue Integer32, com2io8CoilOutputModbusAdd Integer32, com2io8CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3.1.1 com2io8CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io8CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3.1.2 com2io8CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io8CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3.1.3 com2io8CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io8CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3.1.4 com2io8CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io8CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.3.1.5 com2io8CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io8CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4 com2io8InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io8InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io8 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1 com2io8InputRegEntry OBJECT-TYPE SYNTAX Com2io8InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io8InputRegIndex } ::= { com2io8InputRegTable 1 } Com2io8InputRegEntry ::= SEQUENCE { com2io8InputRegIndex Integer32, com2io8InputRegName OCTET STRING, com2io8InputRegValue Opaque, com2io8InputRegModbusAdd Integer32, com2io8InputRegType OCTET STRING, com2io8InputRegScaleRatio Opaque, com2io8InputRegOffset Opaque, com2io8InputRegDeadband Opaque, com2io8InputRegScaleMin Opaque, com2io8InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.1 com2io8InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io8InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.2 com2io8InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io8InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.3 com2io8InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io8InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.4 com2io8InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io8InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.5 com2io8InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io8InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.6 com2io8InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io8InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.7 com2io8InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io8InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.8 com2io8InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io8InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.9 com2io8InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io8InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.4.1.10 com2io8InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io8InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5 com2io8HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io8HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io8 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1 com2io8HoldingRegEntry OBJECT-TYPE SYNTAX Com2io8HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io8HoldingRegIndex } ::= { com2io8HoldingRegTable 1 } Com2io8HoldingRegEntry ::= SEQUENCE { com2io8HoldingRegIndex Integer32, com2io8HoldingRegName OCTET STRING, com2io8HoldingRegValue Opaque, com2io8HoldingRegModbusAdd Integer32, com2io8HoldingRegType OCTET STRING, com2io8HoldingRegScaleRatio Opaque, com2io8HoldingRegOffset Opaque, com2io8HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.1 com2io8HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io8HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.2 com2io8HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io8HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.3 com2io8HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io8HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.4 com2io8HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io8HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.5 com2io8HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io8HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.6 com2io8HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io8HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.7 com2io8HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io8HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.8.5.1.8 com2io8HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io8HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9 com2io9 OBJECT IDENTIFIER ::= { com2io 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1 com2io9BasicInfo OBJECT IDENTIFIER ::= { com2io9 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.1 com2io9Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io9BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.2 com2io9Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io9BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.3 com2io9ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io9BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.4 com2io9ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io9BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.5 com2io9ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io9BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.6 com2io9DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io9BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.7 com2io9CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io9BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.8 com2io9InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io9BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.1.9 com2io9HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io9BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2 com2io9DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io9DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io9 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1 com2io9DiscInputEntry OBJECT-TYPE SYNTAX Com2io9DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io9DiscInputIndex } ::= { com2io9DiscInputTable 1 } Com2io9DiscInputEntry ::= SEQUENCE { com2io9DiscInputIndex Integer32, com2io9DiscInputName OCTET STRING, com2io9DiscInputValue Integer32, com2io9DiscInputModbusAdd Integer32, com2io9DiscInputCounterValue Counter32, com2io9DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1.1 com2io9DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io9DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1.2 com2io9DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io9DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1.3 com2io9DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io9DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1.4 com2io9DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io9DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1.5 com2io9DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io9DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.2.1.6 com2io9DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io9DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3 com2io9CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io9CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io9 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3.1 com2io9CoilOutputEntry OBJECT-TYPE SYNTAX Com2io9CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io9CoilOutputIndex } ::= { com2io9CoilOutputTable 1 } Com2io9CoilOutputEntry ::= SEQUENCE { com2io9CoilOutputIndex Integer32, com2io9CoilOutputName OCTET STRING, com2io9CoilOutputValue Integer32, com2io9CoilOutputModbusAdd Integer32, com2io9CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3.1.1 com2io9CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io9CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3.1.2 com2io9CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io9CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3.1.3 com2io9CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io9CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3.1.4 com2io9CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io9CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.3.1.5 com2io9CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io9CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4 com2io9InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io9InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io9 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1 com2io9InputRegEntry OBJECT-TYPE SYNTAX Com2io9InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io9InputRegIndex } ::= { com2io9InputRegTable 1 } Com2io9InputRegEntry ::= SEQUENCE { com2io9InputRegIndex Integer32, com2io9InputRegName OCTET STRING, com2io9InputRegValue Opaque, com2io9InputRegModbusAdd Integer32, com2io9InputRegType OCTET STRING, com2io9InputRegScaleRatio Opaque, com2io9InputRegOffset Opaque, com2io9InputRegDeadband Opaque, com2io9InputRegScaleMin Opaque, com2io9InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.1 com2io9InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io9InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.2 com2io9InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io9InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.3 com2io9InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io9InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.4 com2io9InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io9InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.5 com2io9InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io9InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.6 com2io9InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io9InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.7 com2io9InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io9InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.8 com2io9InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io9InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.9 com2io9InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io9InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.4.1.10 com2io9InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io9InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5 com2io9HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io9HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io9 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1 com2io9HoldingRegEntry OBJECT-TYPE SYNTAX Com2io9HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io9HoldingRegIndex } ::= { com2io9HoldingRegTable 1 } Com2io9HoldingRegEntry ::= SEQUENCE { com2io9HoldingRegIndex Integer32, com2io9HoldingRegName OCTET STRING, com2io9HoldingRegValue Opaque, com2io9HoldingRegModbusAdd Integer32, com2io9HoldingRegType OCTET STRING, com2io9HoldingRegScaleRatio Opaque, com2io9HoldingRegOffset Opaque, com2io9HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.1 com2io9HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io9HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.2 com2io9HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io9HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.3 com2io9HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io9HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.4 com2io9HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io9HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.5 com2io9HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io9HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.6 com2io9HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io9HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.7 com2io9HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io9HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.9.5.1.8 com2io9HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io9HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10 com2io10 OBJECT IDENTIFIER ::= { com2io 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1 com2io10BasicInfo OBJECT IDENTIFIER ::= { com2io10 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.1 com2io10Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io10BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.2 com2io10Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io10BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.3 com2io10ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io10BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.4 com2io10ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io10BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.5 com2io10ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io10BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.6 com2io10DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io10BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.7 com2io10CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io10BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.8 com2io10InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io10BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.1.9 com2io10HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io10BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2 com2io10DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io10DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io10 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1 com2io10DiscInputEntry OBJECT-TYPE SYNTAX Com2io10DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io10DiscInputIndex } ::= { com2io10DiscInputTable 1 } Com2io10DiscInputEntry ::= SEQUENCE { com2io10DiscInputIndex Integer32, com2io10DiscInputName OCTET STRING, com2io10DiscInputValue Integer32, com2io10DiscInputModbusAdd Integer32, com2io10DiscInputCounterValue Counter32, com2io10DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1.1 com2io10DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io10DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1.2 com2io10DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io10DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1.3 com2io10DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io10DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1.4 com2io10DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io10DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1.5 com2io10DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io10DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.2.1.6 com2io10DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io10DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3 com2io10CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io10CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io10 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3.1 com2io10CoilOutputEntry OBJECT-TYPE SYNTAX Com2io10CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io10CoilOutputIndex } ::= { com2io10CoilOutputTable 1 } Com2io10CoilOutputEntry ::= SEQUENCE { com2io10CoilOutputIndex Integer32, com2io10CoilOutputName OCTET STRING, com2io10CoilOutputValue Integer32, com2io10CoilOutputModbusAdd Integer32, com2io10CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3.1.1 com2io10CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io10CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3.1.2 com2io10CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io10CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3.1.3 com2io10CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io10CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3.1.4 com2io10CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io10CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.3.1.5 com2io10CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io10CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4 com2io10InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io10InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io10 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1 com2io10InputRegEntry OBJECT-TYPE SYNTAX Com2io10InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io10InputRegIndex } ::= { com2io10InputRegTable 1 } Com2io10InputRegEntry ::= SEQUENCE { com2io10InputRegIndex Integer32, com2io10InputRegName OCTET STRING, com2io10InputRegValue Opaque, com2io10InputRegModbusAdd Integer32, com2io10InputRegType OCTET STRING, com2io10InputRegScaleRatio Opaque, com2io10InputRegOffset Opaque, com2io10InputRegDeadband Opaque, com2io10InputRegScaleMin Opaque, com2io10InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.1 com2io10InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io10InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.2 com2io10InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io10InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.3 com2io10InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io10InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.4 com2io10InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io10InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.5 com2io10InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io10InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.6 com2io10InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io10InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.7 com2io10InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io10InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.8 com2io10InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io10InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.9 com2io10InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io10InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.4.1.10 com2io10InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io10InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5 com2io10HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io10HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io10 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1 com2io10HoldingRegEntry OBJECT-TYPE SYNTAX Com2io10HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io10HoldingRegIndex } ::= { com2io10HoldingRegTable 1 } Com2io10HoldingRegEntry ::= SEQUENCE { com2io10HoldingRegIndex Integer32, com2io10HoldingRegName OCTET STRING, com2io10HoldingRegValue Opaque, com2io10HoldingRegModbusAdd Integer32, com2io10HoldingRegType OCTET STRING, com2io10HoldingRegScaleRatio Opaque, com2io10HoldingRegOffset Opaque, com2io10HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.1 com2io10HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io10HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.2 com2io10HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io10HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.3 com2io10HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io10HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.4 com2io10HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io10HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.5 com2io10HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io10HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.6 com2io10HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io10HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.7 com2io10HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io10HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.10.5.1.8 com2io10HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io10HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11 com2io11 OBJECT IDENTIFIER ::= { com2io 11 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1 com2io11BasicInfo OBJECT IDENTIFIER ::= { com2io11 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.1 com2io11Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io11BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.2 com2io11Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io11BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.3 com2io11ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io11BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.4 com2io11ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io11BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.5 com2io11ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io11BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.6 com2io11DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io11BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.7 com2io11CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io11BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.8 com2io11InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io11BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.1.9 com2io11HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io11BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2 com2io11DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io11DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io11 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1 com2io11DiscInputEntry OBJECT-TYPE SYNTAX Com2io11DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io11DiscInputIndex } ::= { com2io11DiscInputTable 1 } Com2io11DiscInputEntry ::= SEQUENCE { com2io11DiscInputIndex Integer32, com2io11DiscInputName OCTET STRING, com2io11DiscInputValue Integer32, com2io11DiscInputModbusAdd Integer32, com2io11DiscInputCounterValue Counter32, com2io11DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1.1 com2io11DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io11DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1.2 com2io11DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io11DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1.3 com2io11DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io11DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1.4 com2io11DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io11DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1.5 com2io11DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io11DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.2.1.6 com2io11DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io11DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3 com2io11CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io11CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io11 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3.1 com2io11CoilOutputEntry OBJECT-TYPE SYNTAX Com2io11CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io11CoilOutputIndex } ::= { com2io11CoilOutputTable 1 } Com2io11CoilOutputEntry ::= SEQUENCE { com2io11CoilOutputIndex Integer32, com2io11CoilOutputName OCTET STRING, com2io11CoilOutputValue Integer32, com2io11CoilOutputModbusAdd Integer32, com2io11CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3.1.1 com2io11CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io11CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3.1.2 com2io11CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io11CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3.1.3 com2io11CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io11CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3.1.4 com2io11CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io11CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.3.1.5 com2io11CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io11CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4 com2io11InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io11InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io11 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1 com2io11InputRegEntry OBJECT-TYPE SYNTAX Com2io11InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io11InputRegIndex } ::= { com2io11InputRegTable 1 } Com2io11InputRegEntry ::= SEQUENCE { com2io11InputRegIndex Integer32, com2io11InputRegName OCTET STRING, com2io11InputRegValue Opaque, com2io11InputRegModbusAdd Integer32, com2io11InputRegType OCTET STRING, com2io11InputRegScaleRatio Opaque, com2io11InputRegOffset Opaque, com2io11InputRegDeadband Opaque, com2io11InputRegScaleMin Opaque, com2io11InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.1 com2io11InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io11InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.2 com2io11InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io11InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.3 com2io11InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io11InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.4 com2io11InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io11InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.5 com2io11InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io11InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.6 com2io11InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io11InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.7 com2io11InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io11InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.8 com2io11InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io11InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.9 com2io11InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io11InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.4.1.10 com2io11InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io11InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5 com2io11HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io11HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io11 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1 com2io11HoldingRegEntry OBJECT-TYPE SYNTAX Com2io11HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io11HoldingRegIndex } ::= { com2io11HoldingRegTable 1 } Com2io11HoldingRegEntry ::= SEQUENCE { com2io11HoldingRegIndex Integer32, com2io11HoldingRegName OCTET STRING, com2io11HoldingRegValue Opaque, com2io11HoldingRegModbusAdd Integer32, com2io11HoldingRegType OCTET STRING, com2io11HoldingRegScaleRatio Opaque, com2io11HoldingRegOffset Opaque, com2io11HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.1 com2io11HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io11HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.2 com2io11HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io11HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.3 com2io11HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io11HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.4 com2io11HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io11HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.5 com2io11HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io11HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.6 com2io11HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io11HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.7 com2io11HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io11HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.11.5.1.8 com2io11HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io11HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12 com2io12 OBJECT IDENTIFIER ::= { com2io 12 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1 com2io12BasicInfo OBJECT IDENTIFIER ::= { com2io12 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.1 com2io12Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io12BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.2 com2io12Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io12BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.3 com2io12ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io12BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.4 com2io12ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io12BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.5 com2io12ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io12BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.6 com2io12DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io12BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.7 com2io12CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io12BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.8 com2io12InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io12BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.1.9 com2io12HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io12BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2 com2io12DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io12DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io12 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1 com2io12DiscInputEntry OBJECT-TYPE SYNTAX Com2io12DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io12DiscInputIndex } ::= { com2io12DiscInputTable 1 } Com2io12DiscInputEntry ::= SEQUENCE { com2io12DiscInputIndex Integer32, com2io12DiscInputName OCTET STRING, com2io12DiscInputValue Integer32, com2io12DiscInputModbusAdd Integer32, com2io12DiscInputCounterValue Counter32, com2io12DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1.1 com2io12DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io12DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1.2 com2io12DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io12DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1.3 com2io12DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io12DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1.4 com2io12DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io12DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1.5 com2io12DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io12DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.2.1.6 com2io12DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io12DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3 com2io12CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io12CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io12 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3.1 com2io12CoilOutputEntry OBJECT-TYPE SYNTAX Com2io12CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io12CoilOutputIndex } ::= { com2io12CoilOutputTable 1 } Com2io12CoilOutputEntry ::= SEQUENCE { com2io12CoilOutputIndex Integer32, com2io12CoilOutputName OCTET STRING, com2io12CoilOutputValue Integer32, com2io12CoilOutputModbusAdd Integer32, com2io12CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3.1.1 com2io12CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io12CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3.1.2 com2io12CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io12CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3.1.3 com2io12CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io12CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3.1.4 com2io12CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io12CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.3.1.5 com2io12CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io12CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4 com2io12InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io12InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io12 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1 com2io12InputRegEntry OBJECT-TYPE SYNTAX Com2io12InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io12InputRegIndex } ::= { com2io12InputRegTable 1 } Com2io12InputRegEntry ::= SEQUENCE { com2io12InputRegIndex Integer32, com2io12InputRegName OCTET STRING, com2io12InputRegValue Opaque, com2io12InputRegModbusAdd Integer32, com2io12InputRegType OCTET STRING, com2io12InputRegScaleRatio Opaque, com2io12InputRegOffset Opaque, com2io12InputRegDeadband Opaque, com2io12InputRegScaleMin Opaque, com2io12InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.1 com2io12InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io12InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.2 com2io12InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io12InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.3 com2io12InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io12InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.4 com2io12InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io12InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.5 com2io12InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io12InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.6 com2io12InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io12InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.7 com2io12InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io12InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.8 com2io12InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io12InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.9 com2io12InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io12InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.4.1.10 com2io12InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io12InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5 com2io12HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io12HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io12 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1 com2io12HoldingRegEntry OBJECT-TYPE SYNTAX Com2io12HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io12HoldingRegIndex } ::= { com2io12HoldingRegTable 1 } Com2io12HoldingRegEntry ::= SEQUENCE { com2io12HoldingRegIndex Integer32, com2io12HoldingRegName OCTET STRING, com2io12HoldingRegValue Opaque, com2io12HoldingRegModbusAdd Integer32, com2io12HoldingRegType OCTET STRING, com2io12HoldingRegScaleRatio Opaque, com2io12HoldingRegOffset Opaque, com2io12HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.1 com2io12HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io12HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.2 com2io12HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io12HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.3 com2io12HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io12HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.4 com2io12HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io12HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.5 com2io12HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io12HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.6 com2io12HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io12HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.7 com2io12HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io12HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.12.5.1.8 com2io12HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io12HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13 com2io13 OBJECT IDENTIFIER ::= { com2io 13 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1 com2io13BasicInfo OBJECT IDENTIFIER ::= { com2io13 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.1 com2io13Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io13BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.2 com2io13Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io13BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.3 com2io13ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io13BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.4 com2io13ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io13BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.5 com2io13ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io13BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.6 com2io13DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io13BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.7 com2io13CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io13BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.8 com2io13InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io13BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.1.9 com2io13HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io13BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2 com2io13DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io13DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io13 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1 com2io13DiscInputEntry OBJECT-TYPE SYNTAX Com2io13DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io13DiscInputIndex } ::= { com2io13DiscInputTable 1 } Com2io13DiscInputEntry ::= SEQUENCE { com2io13DiscInputIndex Integer32, com2io13DiscInputName OCTET STRING, com2io13DiscInputValue Integer32, com2io13DiscInputModbusAdd Integer32, com2io13DiscInputCounterValue Counter32, com2io13DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1.1 com2io13DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io13DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1.2 com2io13DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io13DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1.3 com2io13DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io13DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1.4 com2io13DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io13DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1.5 com2io13DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io13DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.2.1.6 com2io13DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io13DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3 com2io13CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io13CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io13 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3.1 com2io13CoilOutputEntry OBJECT-TYPE SYNTAX Com2io13CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io13CoilOutputIndex } ::= { com2io13CoilOutputTable 1 } Com2io13CoilOutputEntry ::= SEQUENCE { com2io13CoilOutputIndex Integer32, com2io13CoilOutputName OCTET STRING, com2io13CoilOutputValue Integer32, com2io13CoilOutputModbusAdd Integer32, com2io13CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3.1.1 com2io13CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io13CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3.1.2 com2io13CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io13CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3.1.3 com2io13CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io13CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3.1.4 com2io13CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io13CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.3.1.5 com2io13CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io13CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4 com2io13InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io13InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io13 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1 com2io13InputRegEntry OBJECT-TYPE SYNTAX Com2io13InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io13InputRegIndex } ::= { com2io13InputRegTable 1 } Com2io13InputRegEntry ::= SEQUENCE { com2io13InputRegIndex Integer32, com2io13InputRegName OCTET STRING, com2io13InputRegValue Opaque, com2io13InputRegModbusAdd Integer32, com2io13InputRegType OCTET STRING, com2io13InputRegScaleRatio Opaque, com2io13InputRegOffset Opaque, com2io13InputRegDeadband Opaque, com2io13InputRegScaleMin Opaque, com2io13InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.1 com2io13InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io13InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.2 com2io13InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io13InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.3 com2io13InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io13InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.4 com2io13InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io13InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.5 com2io13InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io13InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.6 com2io13InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io13InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.7 com2io13InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io13InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.8 com2io13InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io13InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.9 com2io13InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io13InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.4.1.10 com2io13InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io13InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5 com2io13HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io13HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io13 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1 com2io13HoldingRegEntry OBJECT-TYPE SYNTAX Com2io13HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io13HoldingRegIndex } ::= { com2io13HoldingRegTable 1 } Com2io13HoldingRegEntry ::= SEQUENCE { com2io13HoldingRegIndex Integer32, com2io13HoldingRegName OCTET STRING, com2io13HoldingRegValue Opaque, com2io13HoldingRegModbusAdd Integer32, com2io13HoldingRegType OCTET STRING, com2io13HoldingRegScaleRatio Opaque, com2io13HoldingRegOffset Opaque, com2io13HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.1 com2io13HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io13HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.2 com2io13HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io13HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.3 com2io13HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io13HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.4 com2io13HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io13HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.5 com2io13HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io13HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.6 com2io13HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io13HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.7 com2io13HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io13HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.13.5.1.8 com2io13HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io13HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14 com2io14 OBJECT IDENTIFIER ::= { com2io 14 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1 com2io14BasicInfo OBJECT IDENTIFIER ::= { com2io14 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.1 com2io14Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io14BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.2 com2io14Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io14BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.3 com2io14ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io14BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.4 com2io14ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io14BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.5 com2io14ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io14BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.6 com2io14DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io14BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.7 com2io14CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io14BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.8 com2io14InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io14BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.1.9 com2io14HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io14BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2 com2io14DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io14DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io14 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1 com2io14DiscInputEntry OBJECT-TYPE SYNTAX Com2io14DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io14DiscInputIndex } ::= { com2io14DiscInputTable 1 } Com2io14DiscInputEntry ::= SEQUENCE { com2io14DiscInputIndex Integer32, com2io14DiscInputName OCTET STRING, com2io14DiscInputValue Integer32, com2io14DiscInputModbusAdd Integer32, com2io14DiscInputCounterValue Counter32, com2io14DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1.1 com2io14DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io14DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1.2 com2io14DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io14DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1.3 com2io14DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io14DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1.4 com2io14DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io14DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1.5 com2io14DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io14DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.2.1.6 com2io14DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io14DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3 com2io14CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io14CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io14 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3.1 com2io14CoilOutputEntry OBJECT-TYPE SYNTAX Com2io14CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io14CoilOutputIndex } ::= { com2io14CoilOutputTable 1 } Com2io14CoilOutputEntry ::= SEQUENCE { com2io14CoilOutputIndex Integer32, com2io14CoilOutputName OCTET STRING, com2io14CoilOutputValue Integer32, com2io14CoilOutputModbusAdd Integer32, com2io14CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3.1.1 com2io14CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io14CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3.1.2 com2io14CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io14CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3.1.3 com2io14CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io14CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3.1.4 com2io14CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io14CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.3.1.5 com2io14CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io14CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4 com2io14InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io14InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io14 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1 com2io14InputRegEntry OBJECT-TYPE SYNTAX Com2io14InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io14InputRegIndex } ::= { com2io14InputRegTable 1 } Com2io14InputRegEntry ::= SEQUENCE { com2io14InputRegIndex Integer32, com2io14InputRegName OCTET STRING, com2io14InputRegValue Opaque, com2io14InputRegModbusAdd Integer32, com2io14InputRegType OCTET STRING, com2io14InputRegScaleRatio Opaque, com2io14InputRegOffset Opaque, com2io14InputRegDeadband Opaque, com2io14InputRegScaleMin Opaque, com2io14InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.1 com2io14InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io14InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.2 com2io14InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io14InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.3 com2io14InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io14InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.4 com2io14InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io14InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.5 com2io14InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io14InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.6 com2io14InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io14InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.7 com2io14InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io14InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.8 com2io14InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io14InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.9 com2io14InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io14InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.4.1.10 com2io14InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io14InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5 com2io14HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io14HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io14 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1 com2io14HoldingRegEntry OBJECT-TYPE SYNTAX Com2io14HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io14HoldingRegIndex } ::= { com2io14HoldingRegTable 1 } Com2io14HoldingRegEntry ::= SEQUENCE { com2io14HoldingRegIndex Integer32, com2io14HoldingRegName OCTET STRING, com2io14HoldingRegValue Opaque, com2io14HoldingRegModbusAdd Integer32, com2io14HoldingRegType OCTET STRING, com2io14HoldingRegScaleRatio Opaque, com2io14HoldingRegOffset Opaque, com2io14HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.1 com2io14HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io14HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.2 com2io14HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io14HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.3 com2io14HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io14HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.4 com2io14HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io14HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.5 com2io14HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io14HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.6 com2io14HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io14HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.7 com2io14HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io14HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.14.5.1.8 com2io14HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io14HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15 com2io15 OBJECT IDENTIFIER ::= { com2io 15 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1 com2io15BasicInfo OBJECT IDENTIFIER ::= { com2io15 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.1 com2io15Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io15BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.2 com2io15Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io15BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.3 com2io15ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io15BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.4 com2io15ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io15BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.5 com2io15ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io15BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.6 com2io15DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io15BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.7 com2io15CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io15BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.8 com2io15InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io15BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.1.9 com2io15HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io15BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2 com2io15DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io15DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io15 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1 com2io15DiscInputEntry OBJECT-TYPE SYNTAX Com2io15DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io15DiscInputIndex } ::= { com2io15DiscInputTable 1 } Com2io15DiscInputEntry ::= SEQUENCE { com2io15DiscInputIndex Integer32, com2io15DiscInputName OCTET STRING, com2io15DiscInputValue Integer32, com2io15DiscInputModbusAdd Integer32, com2io15DiscInputCounterValue Counter32, com2io15DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1.1 com2io15DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io15DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1.2 com2io15DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io15DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1.3 com2io15DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io15DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1.4 com2io15DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io15DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1.5 com2io15DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io15DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.2.1.6 com2io15DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io15DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3 com2io15CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io15CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io15 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3.1 com2io15CoilOutputEntry OBJECT-TYPE SYNTAX Com2io15CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io15CoilOutputIndex } ::= { com2io15CoilOutputTable 1 } Com2io15CoilOutputEntry ::= SEQUENCE { com2io15CoilOutputIndex Integer32, com2io15CoilOutputName OCTET STRING, com2io15CoilOutputValue Integer32, com2io15CoilOutputModbusAdd Integer32, com2io15CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3.1.1 com2io15CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io15CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3.1.2 com2io15CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io15CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3.1.3 com2io15CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io15CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3.1.4 com2io15CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io15CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.3.1.5 com2io15CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io15CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4 com2io15InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io15InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io15 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1 com2io15InputRegEntry OBJECT-TYPE SYNTAX Com2io15InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io15InputRegIndex } ::= { com2io15InputRegTable 1 } Com2io15InputRegEntry ::= SEQUENCE { com2io15InputRegIndex Integer32, com2io15InputRegName OCTET STRING, com2io15InputRegValue Opaque, com2io15InputRegModbusAdd Integer32, com2io15InputRegType OCTET STRING, com2io15InputRegScaleRatio Opaque, com2io15InputRegOffset Opaque, com2io15InputRegDeadband Opaque, com2io15InputRegScaleMin Opaque, com2io15InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.1 com2io15InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io15InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.2 com2io15InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io15InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.3 com2io15InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io15InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.4 com2io15InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io15InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.5 com2io15InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io15InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.6 com2io15InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io15InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.7 com2io15InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io15InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.8 com2io15InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io15InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.9 com2io15InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io15InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.4.1.10 com2io15InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io15InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5 com2io15HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io15HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io15 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1 com2io15HoldingRegEntry OBJECT-TYPE SYNTAX Com2io15HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io15HoldingRegIndex } ::= { com2io15HoldingRegTable 1 } Com2io15HoldingRegEntry ::= SEQUENCE { com2io15HoldingRegIndex Integer32, com2io15HoldingRegName OCTET STRING, com2io15HoldingRegValue Opaque, com2io15HoldingRegModbusAdd Integer32, com2io15HoldingRegType OCTET STRING, com2io15HoldingRegScaleRatio Opaque, com2io15HoldingRegOffset Opaque, com2io15HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.1 com2io15HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io15HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.2 com2io15HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io15HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.3 com2io15HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io15HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.4 com2io15HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io15HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.5 com2io15HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io15HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.6 com2io15HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io15HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.7 com2io15HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io15HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.15.5.1.8 com2io15HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io15HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16 com2io16 OBJECT IDENTIFIER ::= { com2io 16 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1 com2io16BasicInfo OBJECT IDENTIFIER ::= { com2io16 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.1 com2io16Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { com2io16BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.2 com2io16Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { com2io16BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.3 com2io16ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { com2io16BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.4 com2io16ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { com2io16BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.5 com2io16ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { com2io16BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.6 com2io16DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { com2io16BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.7 com2io16CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { com2io16BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.8 com2io16InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { com2io16BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.1.9 com2io16HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { com2io16BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2 com2io16DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io16DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io16 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1 com2io16DiscInputEntry OBJECT-TYPE SYNTAX Com2io16DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { com2io16DiscInputIndex } ::= { com2io16DiscInputTable 1 } Com2io16DiscInputEntry ::= SEQUENCE { com2io16DiscInputIndex Integer32, com2io16DiscInputName OCTET STRING, com2io16DiscInputValue Integer32, com2io16DiscInputModbusAdd Integer32, com2io16DiscInputCounterValue Counter32, com2io16DiscInputResetCounter OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1.1 com2io16DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { com2io16DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1.2 com2io16DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { com2io16DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1.3 com2io16DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { com2io16DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1.4 com2io16DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { com2io16DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1.5 com2io16DiscInputCounterValue OBJECT-TYPE SYNTAX Counter32 MAX-ACCESS read-only STATUS current DESCRIPTION "The current counter value of the discrete input data. (This setting is just for ICP DAS M-7000 module.)" ::= { com2io16DiscInputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.2.1.6 com2io16DiscInputResetCounter OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The DI channel counter of the I/O module will be reset to the default value when the PMC is powered on or after loading the rules.This setting is just for ICP DAS M-7000 module.('0' is for 'Disable', '1' is for 'Enable')" ::= { com2io16DiscInputEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3 com2io16CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io16CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { com2io16 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3.1 com2io16CoilOutputEntry OBJECT-TYPE SYNTAX Com2io16CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { com2io16CoilOutputIndex } ::= { com2io16CoilOutputTable 1 } Com2io16CoilOutputEntry ::= SEQUENCE { com2io16CoilOutputIndex Integer32, com2io16CoilOutputName OCTET STRING, com2io16CoilOutputValue Integer32, com2io16CoilOutputModbusAdd Integer32, com2io16CoilOutputAdvFunction OCTET STRING } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3.1.1 com2io16CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { com2io16CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3.1.2 com2io16CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { com2io16CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3.1.3 com2io16CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { com2io16CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3.1.4 com2io16CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { com2io16CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.3.1.5 com2io16CoilOutputAdvFunction OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "PMC provides 2 advanced DO functions for I/O module: 'Auto OFF' and 'DI Status Mapping'. This setting is just for ICP DAS M-7000 module. " ::= { com2io16CoilOutputEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4 com2io16InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io16InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { com2io16 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1 com2io16InputRegEntry OBJECT-TYPE SYNTAX Com2io16InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io16InputRegIndex } ::= { com2io16InputRegTable 1 } Com2io16InputRegEntry ::= SEQUENCE { com2io16InputRegIndex Integer32, com2io16InputRegName OCTET STRING, com2io16InputRegValue Opaque, com2io16InputRegModbusAdd Integer32, com2io16InputRegType OCTET STRING, com2io16InputRegScaleRatio Opaque, com2io16InputRegOffset Opaque, com2io16InputRegDeadband Opaque, com2io16InputRegScaleMin Opaque, com2io16InputRegScaleMax Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.1 com2io16InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { com2io16InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.2 com2io16InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { com2io16InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.3 com2io16InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { com2io16InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.4 com2io16InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { com2io16InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.5 com2io16InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { com2io16InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.6 com2io16InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io16InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.7 com2io16InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { com2io16InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.8 com2io16InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { com2io16InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.9 com2io16InputRegScaleMin OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io16InputRegEntry 9 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.4.1.10 com2io16InputRegScaleMax OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Input Register raw data can be set to operate with linear proportion between 'Min' and 'Max' values. This setting is just for ICP DAS M-7000 module. " ::= { com2io16InputRegEntry 10 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5 com2io16HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Com2io16HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { com2io16 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1 com2io16HoldingRegEntry OBJECT-TYPE SYNTAX Com2io16HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { com2io16HoldingRegIndex } ::= { com2io16HoldingRegTable 1 } Com2io16HoldingRegEntry ::= SEQUENCE { com2io16HoldingRegIndex Integer32, com2io16HoldingRegName OCTET STRING, com2io16HoldingRegValue Opaque, com2io16HoldingRegModbusAdd Integer32, com2io16HoldingRegType OCTET STRING, com2io16HoldingRegScaleRatio Opaque, com2io16HoldingRegOffset Opaque, com2io16HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.1 com2io16HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { com2io16HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.2 com2io16HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { com2io16HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.3 com2io16HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { com2io16HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.4 com2io16HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { com2io16HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.5 com2io16HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { com2io16HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.6 com2io16HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io16HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.7 com2io16HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { com2io16HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.2.16.5.1.8 com2io16HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { com2io16HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3 lanio OBJECT IDENTIFIER ::= { ioModuleInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1 lanio1 OBJECT IDENTIFIER ::= { lanio 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1 lanio1BasicInfo OBJECT IDENTIFIER ::= { lanio1 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.1 lanio1Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio1BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.2 lanio1Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio1BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.3 lanio1ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio1BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.4 lanio1ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio1BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.5 lanio1ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio1BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.6 lanio1DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio1BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.7 lanio1CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio1BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.8 lanio1InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio1BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.1.9 lanio1HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio1BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.2 lanio1DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio1DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio1 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.2.1 lanio1DiscInputEntry OBJECT-TYPE SYNTAX Lanio1DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio1DiscInputIndex } ::= { lanio1DiscInputTable 1 } Lanio1DiscInputEntry ::= SEQUENCE { lanio1DiscInputIndex Integer32, lanio1DiscInputName OCTET STRING, lanio1DiscInputValue Integer32, lanio1DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.2.1.1 lanio1DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio1DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.2.1.2 lanio1DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio1DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.2.1.3 lanio1DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio1DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.2.1.4 lanio1DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio1DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.3 lanio1CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio1CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio1 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.3.1 lanio1CoilOutputEntry OBJECT-TYPE SYNTAX Lanio1CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio1CoilOutputIndex } ::= { lanio1CoilOutputTable 1 } Lanio1CoilOutputEntry ::= SEQUENCE { lanio1CoilOutputIndex Integer32, lanio1CoilOutputName OCTET STRING, lanio1CoilOutputValue Integer32, lanio1CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.3.1.1 lanio1CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio1CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.3.1.2 lanio1CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio1CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.3.1.3 lanio1CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio1CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.3.1.4 lanio1CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio1CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4 lanio1InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio1InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio1 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1 lanio1InputRegEntry OBJECT-TYPE SYNTAX Lanio1InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio1InputRegIndex } ::= { lanio1InputRegTable 1 } Lanio1InputRegEntry ::= SEQUENCE { lanio1InputRegIndex Integer32, lanio1InputRegName OCTET STRING, lanio1InputRegValue Opaque, lanio1InputRegModbusAdd Integer32, lanio1InputRegType OCTET STRING, lanio1InputRegScaleRatio Opaque, lanio1InputRegOffset Opaque, lanio1InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.1 lanio1InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio1InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.2 lanio1InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio1InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.3 lanio1InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio1InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.4 lanio1InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio1InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.5 lanio1InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio1InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.6 lanio1InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio1InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.7 lanio1InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio1InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.4.1.8 lanio1InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio1InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5 lanio1HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio1HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio1 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1 lanio1HoldingRegEntry OBJECT-TYPE SYNTAX Lanio1HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio1HoldingRegIndex } ::= { lanio1HoldingRegTable 1 } Lanio1HoldingRegEntry ::= SEQUENCE { lanio1HoldingRegIndex Integer32, lanio1HoldingRegName OCTET STRING, lanio1HoldingRegValue Opaque, lanio1HoldingRegModbusAdd Integer32, lanio1HoldingRegType OCTET STRING, lanio1HoldingRegScaleRatio Opaque, lanio1HoldingRegOffset Opaque, lanio1HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.1 lanio1HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio1HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.2 lanio1HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio1HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.3 lanio1HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio1HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.4 lanio1HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio1HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.5 lanio1HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio1HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.6 lanio1HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio1HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.7 lanio1HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio1HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.1.5.1.8 lanio1HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio1HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2 lanio2 OBJECT IDENTIFIER ::= { lanio 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1 lanio2BasicInfo OBJECT IDENTIFIER ::= { lanio2 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.1 lanio2Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio2BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.2 lanio2Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio2BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.3 lanio2ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio2BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.4 lanio2ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio2BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.5 lanio2ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio2BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.6 lanio2DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio2BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.7 lanio2CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio2BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.8 lanio2InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio2BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.1.9 lanio2HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio2BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.2 lanio2DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio2DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio2 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.2.1 lanio2DiscInputEntry OBJECT-TYPE SYNTAX Lanio2DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio2DiscInputIndex } ::= { lanio2DiscInputTable 1 } Lanio2DiscInputEntry ::= SEQUENCE { lanio2DiscInputIndex Integer32, lanio2DiscInputName OCTET STRING, lanio2DiscInputValue Integer32, lanio2DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.2.1.1 lanio2DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio2DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.2.1.2 lanio2DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio2DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.2.1.3 lanio2DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio2DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.2.1.4 lanio2DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio2DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.3 lanio2CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio2CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio2 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.3.1 lanio2CoilOutputEntry OBJECT-TYPE SYNTAX Lanio2CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio2CoilOutputIndex } ::= { lanio2CoilOutputTable 1 } Lanio2CoilOutputEntry ::= SEQUENCE { lanio2CoilOutputIndex Integer32, lanio2CoilOutputName OCTET STRING, lanio2CoilOutputValue Integer32, lanio2CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.3.1.1 lanio2CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio2CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.3.1.2 lanio2CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio2CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.3.1.3 lanio2CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio2CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.3.1.4 lanio2CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio2CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4 lanio2InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio2InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio2 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1 lanio2InputRegEntry OBJECT-TYPE SYNTAX Lanio2InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio2InputRegIndex } ::= { lanio2InputRegTable 1 } Lanio2InputRegEntry ::= SEQUENCE { lanio2InputRegIndex Integer32, lanio2InputRegName OCTET STRING, lanio2InputRegValue Opaque, lanio2InputRegModbusAdd Integer32, lanio2InputRegType OCTET STRING, lanio2InputRegScaleRatio Opaque, lanio2InputRegOffset Opaque, lanio2InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.1 lanio2InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio2InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.2 lanio2InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio2InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.3 lanio2InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio2InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.4 lanio2InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio2InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.5 lanio2InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio2InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.6 lanio2InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio2InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.7 lanio2InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio2InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.4.1.8 lanio2InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio2InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5 lanio2HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio2HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio2 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1 lanio2HoldingRegEntry OBJECT-TYPE SYNTAX Lanio2HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio2HoldingRegIndex } ::= { lanio2HoldingRegTable 1 } Lanio2HoldingRegEntry ::= SEQUENCE { lanio2HoldingRegIndex Integer32, lanio2HoldingRegName OCTET STRING, lanio2HoldingRegValue Opaque, lanio2HoldingRegModbusAdd Integer32, lanio2HoldingRegType OCTET STRING, lanio2HoldingRegScaleRatio Opaque, lanio2HoldingRegOffset Opaque, lanio2HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.1 lanio2HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio2HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.2 lanio2HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio2HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.3 lanio2HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio2HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.4 lanio2HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio2HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.5 lanio2HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio2HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.6 lanio2HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio2HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.7 lanio2HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio2HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.2.5.1.8 lanio2HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio2HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3 lanio3 OBJECT IDENTIFIER ::= { lanio 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1 lanio3BasicInfo OBJECT IDENTIFIER ::= { lanio3 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.1 lanio3Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio3BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.2 lanio3Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio3BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.3 lanio3ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio3BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.4 lanio3ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio3BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.5 lanio3ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio3BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.6 lanio3DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio3BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.7 lanio3CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio3BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.8 lanio3InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio3BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.1.9 lanio3HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio3BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.2 lanio3DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio3DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio3 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.2.1 lanio3DiscInputEntry OBJECT-TYPE SYNTAX Lanio3DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio3DiscInputIndex } ::= { lanio3DiscInputTable 1 } Lanio3DiscInputEntry ::= SEQUENCE { lanio3DiscInputIndex Integer32, lanio3DiscInputName OCTET STRING, lanio3DiscInputValue Integer32, lanio3DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.2.1.1 lanio3DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio3DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.2.1.2 lanio3DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio3DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.2.1.3 lanio3DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio3DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.2.1.4 lanio3DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio3DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.3 lanio3CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio3CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio3 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.3.1 lanio3CoilOutputEntry OBJECT-TYPE SYNTAX Lanio3CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio3CoilOutputIndex } ::= { lanio3CoilOutputTable 1 } Lanio3CoilOutputEntry ::= SEQUENCE { lanio3CoilOutputIndex Integer32, lanio3CoilOutputName OCTET STRING, lanio3CoilOutputValue Integer32, lanio3CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.3.1.1 lanio3CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio3CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.3.1.2 lanio3CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio3CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.3.1.3 lanio3CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio3CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.3.1.4 lanio3CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio3CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4 lanio3InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio3InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio3 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1 lanio3InputRegEntry OBJECT-TYPE SYNTAX Lanio3InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio3InputRegIndex } ::= { lanio3InputRegTable 1 } Lanio3InputRegEntry ::= SEQUENCE { lanio3InputRegIndex Integer32, lanio3InputRegName OCTET STRING, lanio3InputRegValue Opaque, lanio3InputRegModbusAdd Integer32, lanio3InputRegType OCTET STRING, lanio3InputRegScaleRatio Opaque, lanio3InputRegOffset Opaque, lanio3InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.1 lanio3InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio3InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.2 lanio3InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio3InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.3 lanio3InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio3InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.4 lanio3InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio3InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.5 lanio3InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio3InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.6 lanio3InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio3InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.7 lanio3InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio3InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.4.1.8 lanio3InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio3InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5 lanio3HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio3HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio3 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1 lanio3HoldingRegEntry OBJECT-TYPE SYNTAX Lanio3HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio3HoldingRegIndex } ::= { lanio3HoldingRegTable 1 } Lanio3HoldingRegEntry ::= SEQUENCE { lanio3HoldingRegIndex Integer32, lanio3HoldingRegName OCTET STRING, lanio3HoldingRegValue Opaque, lanio3HoldingRegModbusAdd Integer32, lanio3HoldingRegType OCTET STRING, lanio3HoldingRegScaleRatio Opaque, lanio3HoldingRegOffset Opaque, lanio3HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.1 lanio3HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio3HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.2 lanio3HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio3HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.3 lanio3HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio3HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.4 lanio3HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio3HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.5 lanio3HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio3HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.6 lanio3HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio3HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.7 lanio3HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio3HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.3.5.1.8 lanio3HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio3HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4 lanio4 OBJECT IDENTIFIER ::= { lanio 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1 lanio4BasicInfo OBJECT IDENTIFIER ::= { lanio4 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.1 lanio4Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio4BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.2 lanio4Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio4BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.3 lanio4ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio4BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.4 lanio4ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio4BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.5 lanio4ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio4BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.6 lanio4DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio4BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.7 lanio4CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio4BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.8 lanio4InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio4BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.1.9 lanio4HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio4BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.2 lanio4DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio4DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio4 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.2.1 lanio4DiscInputEntry OBJECT-TYPE SYNTAX Lanio4DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio4DiscInputIndex } ::= { lanio4DiscInputTable 1 } Lanio4DiscInputEntry ::= SEQUENCE { lanio4DiscInputIndex Integer32, lanio4DiscInputName OCTET STRING, lanio4DiscInputValue Integer32, lanio4DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.2.1.1 lanio4DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio4DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.2.1.2 lanio4DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio4DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.2.1.3 lanio4DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio4DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.2.1.4 lanio4DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio4DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.3 lanio4CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio4CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio4 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.3.1 lanio4CoilOutputEntry OBJECT-TYPE SYNTAX Lanio4CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio4CoilOutputIndex } ::= { lanio4CoilOutputTable 1 } Lanio4CoilOutputEntry ::= SEQUENCE { lanio4CoilOutputIndex Integer32, lanio4CoilOutputName OCTET STRING, lanio4CoilOutputValue Integer32, lanio4CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.3.1.1 lanio4CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio4CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.3.1.2 lanio4CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio4CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.3.1.3 lanio4CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio4CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.3.1.4 lanio4CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio4CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4 lanio4InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio4InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio4 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1 lanio4InputRegEntry OBJECT-TYPE SYNTAX Lanio4InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio4InputRegIndex } ::= { lanio4InputRegTable 1 } Lanio4InputRegEntry ::= SEQUENCE { lanio4InputRegIndex Integer32, lanio4InputRegName OCTET STRING, lanio4InputRegValue Opaque, lanio4InputRegModbusAdd Integer32, lanio4InputRegType OCTET STRING, lanio4InputRegScaleRatio Opaque, lanio4InputRegOffset Opaque, lanio4InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.1 lanio4InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio4InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.2 lanio4InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio4InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.3 lanio4InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio4InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.4 lanio4InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio4InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.5 lanio4InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio4InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.6 lanio4InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio4InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.7 lanio4InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio4InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.4.1.8 lanio4InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio4InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5 lanio4HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio4HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio4 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1 lanio4HoldingRegEntry OBJECT-TYPE SYNTAX Lanio4HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio4HoldingRegIndex } ::= { lanio4HoldingRegTable 1 } Lanio4HoldingRegEntry ::= SEQUENCE { lanio4HoldingRegIndex Integer32, lanio4HoldingRegName OCTET STRING, lanio4HoldingRegValue Opaque, lanio4HoldingRegModbusAdd Integer32, lanio4HoldingRegType OCTET STRING, lanio4HoldingRegScaleRatio Opaque, lanio4HoldingRegOffset Opaque, lanio4HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.1 lanio4HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio4HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.2 lanio4HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio4HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.3 lanio4HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio4HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.4 lanio4HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio4HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.5 lanio4HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio4HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.6 lanio4HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio4HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.7 lanio4HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio4HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.4.5.1.8 lanio4HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio4HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5 lanio5 OBJECT IDENTIFIER ::= { lanio 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1 lanio5BasicInfo OBJECT IDENTIFIER ::= { lanio5 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.1 lanio5Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio5BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.2 lanio5Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio5BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.3 lanio5ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio5BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.4 lanio5ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio5BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.5 lanio5ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio5BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.6 lanio5DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio5BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.7 lanio5CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio5BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.8 lanio5InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio5BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.1.9 lanio5HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio5BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.2 lanio5DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio5DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio5 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.2.1 lanio5DiscInputEntry OBJECT-TYPE SYNTAX Lanio5DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio5DiscInputIndex } ::= { lanio5DiscInputTable 1 } Lanio5DiscInputEntry ::= SEQUENCE { lanio5DiscInputIndex Integer32, lanio5DiscInputName OCTET STRING, lanio5DiscInputValue Integer32, lanio5DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.2.1.1 lanio5DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio5DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.2.1.2 lanio5DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio5DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.2.1.3 lanio5DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio5DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.2.1.4 lanio5DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio5DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.3 lanio5CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio5CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio5 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.3.1 lanio5CoilOutputEntry OBJECT-TYPE SYNTAX Lanio5CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio5CoilOutputIndex } ::= { lanio5CoilOutputTable 1 } Lanio5CoilOutputEntry ::= SEQUENCE { lanio5CoilOutputIndex Integer32, lanio5CoilOutputName OCTET STRING, lanio5CoilOutputValue Integer32, lanio5CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.3.1.1 lanio5CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio5CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.3.1.2 lanio5CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio5CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.3.1.3 lanio5CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio5CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.3.1.4 lanio5CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio5CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4 lanio5InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio5InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio5 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1 lanio5InputRegEntry OBJECT-TYPE SYNTAX Lanio5InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio5InputRegIndex } ::= { lanio5InputRegTable 1 } Lanio5InputRegEntry ::= SEQUENCE { lanio5InputRegIndex Integer32, lanio5InputRegName OCTET STRING, lanio5InputRegValue Opaque, lanio5InputRegModbusAdd Integer32, lanio5InputRegType OCTET STRING, lanio5InputRegScaleRatio Opaque, lanio5InputRegOffset Opaque, lanio5InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.1 lanio5InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio5InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.2 lanio5InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio5InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.3 lanio5InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio5InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.4 lanio5InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio5InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.5 lanio5InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio5InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.6 lanio5InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio5InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.7 lanio5InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio5InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.4.1.8 lanio5InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio5InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5 lanio5HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio5HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio5 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1 lanio5HoldingRegEntry OBJECT-TYPE SYNTAX Lanio5HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio5HoldingRegIndex } ::= { lanio5HoldingRegTable 1 } Lanio5HoldingRegEntry ::= SEQUENCE { lanio5HoldingRegIndex Integer32, lanio5HoldingRegName OCTET STRING, lanio5HoldingRegValue Opaque, lanio5HoldingRegModbusAdd Integer32, lanio5HoldingRegType OCTET STRING, lanio5HoldingRegScaleRatio Opaque, lanio5HoldingRegOffset Opaque, lanio5HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.1 lanio5HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio5HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.2 lanio5HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio5HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.3 lanio5HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio5HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.4 lanio5HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio5HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.5 lanio5HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio5HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.6 lanio5HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio5HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.7 lanio5HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio5HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.5.5.1.8 lanio5HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio5HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6 lanio6 OBJECT IDENTIFIER ::= { lanio 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1 lanio6BasicInfo OBJECT IDENTIFIER ::= { lanio6 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.1 lanio6Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio6BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.2 lanio6Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio6BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.3 lanio6ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio6BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.4 lanio6ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio6BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.5 lanio6ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio6BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.6 lanio6DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio6BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.7 lanio6CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio6BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.8 lanio6InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio6BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.1.9 lanio6HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio6BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.2 lanio6DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio6DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio6 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.2.1 lanio6DiscInputEntry OBJECT-TYPE SYNTAX Lanio6DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio6DiscInputIndex } ::= { lanio6DiscInputTable 1 } Lanio6DiscInputEntry ::= SEQUENCE { lanio6DiscInputIndex Integer32, lanio6DiscInputName OCTET STRING, lanio6DiscInputValue Integer32, lanio6DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.2.1.1 lanio6DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio6DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.2.1.2 lanio6DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio6DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.2.1.3 lanio6DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio6DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.2.1.4 lanio6DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio6DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.3 lanio6CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio6CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio6 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.3.1 lanio6CoilOutputEntry OBJECT-TYPE SYNTAX Lanio6CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio6CoilOutputIndex } ::= { lanio6CoilOutputTable 1 } Lanio6CoilOutputEntry ::= SEQUENCE { lanio6CoilOutputIndex Integer32, lanio6CoilOutputName OCTET STRING, lanio6CoilOutputValue Integer32, lanio6CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.3.1.1 lanio6CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio6CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.3.1.2 lanio6CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio6CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.3.1.3 lanio6CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio6CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.3.1.4 lanio6CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio6CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4 lanio6InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio6InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio6 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1 lanio6InputRegEntry OBJECT-TYPE SYNTAX Lanio6InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio6InputRegIndex } ::= { lanio6InputRegTable 1 } Lanio6InputRegEntry ::= SEQUENCE { lanio6InputRegIndex Integer32, lanio6InputRegName OCTET STRING, lanio6InputRegValue Opaque, lanio6InputRegModbusAdd Integer32, lanio6InputRegType OCTET STRING, lanio6InputRegScaleRatio Opaque, lanio6InputRegOffset Opaque, lanio6InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.1 lanio6InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio6InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.2 lanio6InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio6InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.3 lanio6InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio6InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.4 lanio6InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio6InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.5 lanio6InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio6InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.6 lanio6InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio6InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.7 lanio6InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio6InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.4.1.8 lanio6InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio6InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5 lanio6HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio6HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio6 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1 lanio6HoldingRegEntry OBJECT-TYPE SYNTAX Lanio6HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio6HoldingRegIndex } ::= { lanio6HoldingRegTable 1 } Lanio6HoldingRegEntry ::= SEQUENCE { lanio6HoldingRegIndex Integer32, lanio6HoldingRegName OCTET STRING, lanio6HoldingRegValue Opaque, lanio6HoldingRegModbusAdd Integer32, lanio6HoldingRegType OCTET STRING, lanio6HoldingRegScaleRatio Opaque, lanio6HoldingRegOffset Opaque, lanio6HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.1 lanio6HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio6HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.2 lanio6HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio6HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.3 lanio6HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio6HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.4 lanio6HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio6HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.5 lanio6HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio6HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.6 lanio6HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio6HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.7 lanio6HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio6HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.6.5.1.8 lanio6HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio6HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7 lanio7 OBJECT IDENTIFIER ::= { lanio 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1 lanio7BasicInfo OBJECT IDENTIFIER ::= { lanio7 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.1 lanio7Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio7BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.2 lanio7Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio7BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.3 lanio7ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio7BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.4 lanio7ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio7BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.5 lanio7ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio7BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.6 lanio7DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio7BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.7 lanio7CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio7BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.8 lanio7InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio7BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.1.9 lanio7HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio7BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.2 lanio7DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio7DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio7 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.2.1 lanio7DiscInputEntry OBJECT-TYPE SYNTAX Lanio7DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio7DiscInputIndex } ::= { lanio7DiscInputTable 1 } Lanio7DiscInputEntry ::= SEQUENCE { lanio7DiscInputIndex Integer32, lanio7DiscInputName OCTET STRING, lanio7DiscInputValue Integer32, lanio7DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.2.1.1 lanio7DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio7DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.2.1.2 lanio7DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio7DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.2.1.3 lanio7DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio7DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.2.1.4 lanio7DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio7DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.3 lanio7CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio7CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio7 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.3.1 lanio7CoilOutputEntry OBJECT-TYPE SYNTAX Lanio7CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio7CoilOutputIndex } ::= { lanio7CoilOutputTable 1 } Lanio7CoilOutputEntry ::= SEQUENCE { lanio7CoilOutputIndex Integer32, lanio7CoilOutputName OCTET STRING, lanio7CoilOutputValue Integer32, lanio7CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.3.1.1 lanio7CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio7CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.3.1.2 lanio7CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio7CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.3.1.3 lanio7CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio7CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.3.1.4 lanio7CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio7CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4 lanio7InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio7InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio7 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1 lanio7InputRegEntry OBJECT-TYPE SYNTAX Lanio7InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio7InputRegIndex } ::= { lanio7InputRegTable 1 } Lanio7InputRegEntry ::= SEQUENCE { lanio7InputRegIndex Integer32, lanio7InputRegName OCTET STRING, lanio7InputRegValue Opaque, lanio7InputRegModbusAdd Integer32, lanio7InputRegType OCTET STRING, lanio7InputRegScaleRatio Opaque, lanio7InputRegOffset Opaque, lanio7InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.1 lanio7InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio7InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.2 lanio7InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio7InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.3 lanio7InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio7InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.4 lanio7InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio7InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.5 lanio7InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio7InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.6 lanio7InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio7InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.7 lanio7InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio7InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.4.1.8 lanio7InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio7InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5 lanio7HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio7HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio7 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1 lanio7HoldingRegEntry OBJECT-TYPE SYNTAX Lanio7HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio7HoldingRegIndex } ::= { lanio7HoldingRegTable 1 } Lanio7HoldingRegEntry ::= SEQUENCE { lanio7HoldingRegIndex Integer32, lanio7HoldingRegName OCTET STRING, lanio7HoldingRegValue Opaque, lanio7HoldingRegModbusAdd Integer32, lanio7HoldingRegType OCTET STRING, lanio7HoldingRegScaleRatio Opaque, lanio7HoldingRegOffset Opaque, lanio7HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.1 lanio7HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio7HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.2 lanio7HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio7HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.3 lanio7HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio7HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.4 lanio7HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio7HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.5 lanio7HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio7HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.6 lanio7HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio7HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.7 lanio7HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio7HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.7.5.1.8 lanio7HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio7HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8 lanio8 OBJECT IDENTIFIER ::= { lanio 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1 lanio8BasicInfo OBJECT IDENTIFIER ::= { lanio8 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.1 lanio8Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio8BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.2 lanio8Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio8BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.3 lanio8ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio8BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.4 lanio8ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio8BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.5 lanio8ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio8BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.6 lanio8DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio8BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.7 lanio8CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio8BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.8 lanio8InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio8BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.1.9 lanio8HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio8BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.2 lanio8DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio8DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio8 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.2.1 lanio8DiscInputEntry OBJECT-TYPE SYNTAX Lanio8DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio8DiscInputIndex } ::= { lanio8DiscInputTable 1 } Lanio8DiscInputEntry ::= SEQUENCE { lanio8DiscInputIndex Integer32, lanio8DiscInputName OCTET STRING, lanio8DiscInputValue Integer32, lanio8DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.2.1.1 lanio8DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio8DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.2.1.2 lanio8DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio8DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.2.1.3 lanio8DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio8DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.2.1.4 lanio8DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio8DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.3 lanio8CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio8CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio8 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.3.1 lanio8CoilOutputEntry OBJECT-TYPE SYNTAX Lanio8CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio8CoilOutputIndex } ::= { lanio8CoilOutputTable 1 } Lanio8CoilOutputEntry ::= SEQUENCE { lanio8CoilOutputIndex Integer32, lanio8CoilOutputName OCTET STRING, lanio8CoilOutputValue Integer32, lanio8CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.3.1.1 lanio8CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio8CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.3.1.2 lanio8CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio8CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.3.1.3 lanio8CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio8CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.3.1.4 lanio8CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio8CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4 lanio8InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio8InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio8 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1 lanio8InputRegEntry OBJECT-TYPE SYNTAX Lanio8InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio8InputRegIndex } ::= { lanio8InputRegTable 1 } Lanio8InputRegEntry ::= SEQUENCE { lanio8InputRegIndex Integer32, lanio8InputRegName OCTET STRING, lanio8InputRegValue Opaque, lanio8InputRegModbusAdd Integer32, lanio8InputRegType OCTET STRING, lanio8InputRegScaleRatio Opaque, lanio8InputRegOffset Opaque, lanio8InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.1 lanio8InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio8InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.2 lanio8InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio8InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.3 lanio8InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio8InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.4 lanio8InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio8InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.5 lanio8InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio8InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.6 lanio8InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio8InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.7 lanio8InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio8InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.4.1.8 lanio8InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio8InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5 lanio8HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio8HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio8 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1 lanio8HoldingRegEntry OBJECT-TYPE SYNTAX Lanio8HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio8HoldingRegIndex } ::= { lanio8HoldingRegTable 1 } Lanio8HoldingRegEntry ::= SEQUENCE { lanio8HoldingRegIndex Integer32, lanio8HoldingRegName OCTET STRING, lanio8HoldingRegValue Opaque, lanio8HoldingRegModbusAdd Integer32, lanio8HoldingRegType OCTET STRING, lanio8HoldingRegScaleRatio Opaque, lanio8HoldingRegOffset Opaque, lanio8HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.1 lanio8HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio8HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.2 lanio8HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio8HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.3 lanio8HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio8HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.4 lanio8HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio8HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.5 lanio8HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio8HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.6 lanio8HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio8HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.7 lanio8HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio8HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.8.5.1.8 lanio8HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio8HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9 lanio9 OBJECT IDENTIFIER ::= { lanio 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1 lanio9BasicInfo OBJECT IDENTIFIER ::= { lanio9 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.1 lanio9Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio9BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.2 lanio9Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio9BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.3 lanio9ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio9BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.4 lanio9ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio9BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.5 lanio9ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio9BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.6 lanio9DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio9BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.7 lanio9CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio9BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.8 lanio9InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio9BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.1.9 lanio9HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio9BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.2 lanio9DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio9DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio9 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.2.1 lanio9DiscInputEntry OBJECT-TYPE SYNTAX Lanio9DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio9DiscInputIndex } ::= { lanio9DiscInputTable 1 } Lanio9DiscInputEntry ::= SEQUENCE { lanio9DiscInputIndex Integer32, lanio9DiscInputName OCTET STRING, lanio9DiscInputValue Integer32, lanio9DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.2.1.1 lanio9DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio9DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.2.1.2 lanio9DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio9DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.2.1.3 lanio9DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio9DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.2.1.4 lanio9DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio9DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.3 lanio9CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio9CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio9 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.3.1 lanio9CoilOutputEntry OBJECT-TYPE SYNTAX Lanio9CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio9CoilOutputIndex } ::= { lanio9CoilOutputTable 1 } Lanio9CoilOutputEntry ::= SEQUENCE { lanio9CoilOutputIndex Integer32, lanio9CoilOutputName OCTET STRING, lanio9CoilOutputValue Integer32, lanio9CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.3.1.1 lanio9CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio9CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.3.1.2 lanio9CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio9CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.3.1.3 lanio9CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio9CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.3.1.4 lanio9CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio9CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4 lanio9InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio9InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio9 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1 lanio9InputRegEntry OBJECT-TYPE SYNTAX Lanio9InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio9InputRegIndex } ::= { lanio9InputRegTable 1 } Lanio9InputRegEntry ::= SEQUENCE { lanio9InputRegIndex Integer32, lanio9InputRegName OCTET STRING, lanio9InputRegValue Opaque, lanio9InputRegModbusAdd Integer32, lanio9InputRegType OCTET STRING, lanio9InputRegScaleRatio Opaque, lanio9InputRegOffset Opaque, lanio9InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.1 lanio9InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio9InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.2 lanio9InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio9InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.3 lanio9InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio9InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.4 lanio9InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio9InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.5 lanio9InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio9InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.6 lanio9InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio9InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.7 lanio9InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio9InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.4.1.8 lanio9InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio9InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5 lanio9HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio9HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio9 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1 lanio9HoldingRegEntry OBJECT-TYPE SYNTAX Lanio9HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio9HoldingRegIndex } ::= { lanio9HoldingRegTable 1 } Lanio9HoldingRegEntry ::= SEQUENCE { lanio9HoldingRegIndex Integer32, lanio9HoldingRegName OCTET STRING, lanio9HoldingRegValue Opaque, lanio9HoldingRegModbusAdd Integer32, lanio9HoldingRegType OCTET STRING, lanio9HoldingRegScaleRatio Opaque, lanio9HoldingRegOffset Opaque, lanio9HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.1 lanio9HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio9HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.2 lanio9HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio9HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.3 lanio9HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio9HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.4 lanio9HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio9HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.5 lanio9HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio9HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.6 lanio9HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio9HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.7 lanio9HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio9HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.9.5.1.8 lanio9HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio9HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10 lanio10 OBJECT IDENTIFIER ::= { lanio 10 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1 lanio10BasicInfo OBJECT IDENTIFIER ::= { lanio10 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.1 lanio10Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio10BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.2 lanio10Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio10BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.3 lanio10ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio10BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.4 lanio10ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio10BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.5 lanio10ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio10BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.6 lanio10DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio10BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.7 lanio10CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio10BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.8 lanio10InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio10BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.1.9 lanio10HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio10BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.2 lanio10DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio10DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio10 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.2.1 lanio10DiscInputEntry OBJECT-TYPE SYNTAX Lanio10DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio10DiscInputIndex } ::= { lanio10DiscInputTable 1 } Lanio10DiscInputEntry ::= SEQUENCE { lanio10DiscInputIndex Integer32, lanio10DiscInputName OCTET STRING, lanio10DiscInputValue Integer32, lanio10DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.2.1.1 lanio10DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio10DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.2.1.2 lanio10DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio10DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.2.1.3 lanio10DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio10DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.2.1.4 lanio10DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio10DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.3 lanio10CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio10CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio10 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.3.1 lanio10CoilOutputEntry OBJECT-TYPE SYNTAX Lanio10CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio10CoilOutputIndex } ::= { lanio10CoilOutputTable 1 } Lanio10CoilOutputEntry ::= SEQUENCE { lanio10CoilOutputIndex Integer32, lanio10CoilOutputName OCTET STRING, lanio10CoilOutputValue Integer32, lanio10CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.3.1.1 lanio10CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio10CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.3.1.2 lanio10CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio10CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.3.1.3 lanio10CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio10CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.3.1.4 lanio10CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio10CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4 lanio10InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio10InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio10 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1 lanio10InputRegEntry OBJECT-TYPE SYNTAX Lanio10InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio10InputRegIndex } ::= { lanio10InputRegTable 1 } Lanio10InputRegEntry ::= SEQUENCE { lanio10InputRegIndex Integer32, lanio10InputRegName OCTET STRING, lanio10InputRegValue Opaque, lanio10InputRegModbusAdd Integer32, lanio10InputRegType OCTET STRING, lanio10InputRegScaleRatio Opaque, lanio10InputRegOffset Opaque, lanio10InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.1 lanio10InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio10InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.2 lanio10InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio10InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.3 lanio10InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio10InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.4 lanio10InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio10InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.5 lanio10InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio10InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.6 lanio10InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio10InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.7 lanio10InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio10InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.4.1.8 lanio10InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio10InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5 lanio10HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio10HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio10 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1 lanio10HoldingRegEntry OBJECT-TYPE SYNTAX Lanio10HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio10HoldingRegIndex } ::= { lanio10HoldingRegTable 1 } Lanio10HoldingRegEntry ::= SEQUENCE { lanio10HoldingRegIndex Integer32, lanio10HoldingRegName OCTET STRING, lanio10HoldingRegValue Opaque, lanio10HoldingRegModbusAdd Integer32, lanio10HoldingRegType OCTET STRING, lanio10HoldingRegScaleRatio Opaque, lanio10HoldingRegOffset Opaque, lanio10HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.1 lanio10HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio10HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.2 lanio10HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio10HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.3 lanio10HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio10HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.4 lanio10HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio10HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.5 lanio10HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio10HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.6 lanio10HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio10HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.7 lanio10HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio10HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.10.5.1.8 lanio10HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio10HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11 lanio11 OBJECT IDENTIFIER ::= { lanio 11 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1 lanio11BasicInfo OBJECT IDENTIFIER ::= { lanio11 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.1 lanio11Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio11BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.2 lanio11Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio11BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.3 lanio11ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio11BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.4 lanio11ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio11BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.5 lanio11ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio11BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.6 lanio11DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio11BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.7 lanio11CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio11BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.8 lanio11InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio11BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.1.9 lanio11HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio11BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.2 lanio11DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio11DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio11 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.2.1 lanio11DiscInputEntry OBJECT-TYPE SYNTAX Lanio11DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio11DiscInputIndex } ::= { lanio11DiscInputTable 1 } Lanio11DiscInputEntry ::= SEQUENCE { lanio11DiscInputIndex Integer32, lanio11DiscInputName OCTET STRING, lanio11DiscInputValue Integer32, lanio11DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.2.1.1 lanio11DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio11DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.2.1.2 lanio11DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio11DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.2.1.3 lanio11DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio11DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.2.1.4 lanio11DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio11DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.3 lanio11CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio11CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio11 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.3.1 lanio11CoilOutputEntry OBJECT-TYPE SYNTAX Lanio11CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio11CoilOutputIndex } ::= { lanio11CoilOutputTable 1 } Lanio11CoilOutputEntry ::= SEQUENCE { lanio11CoilOutputIndex Integer32, lanio11CoilOutputName OCTET STRING, lanio11CoilOutputValue Integer32, lanio11CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.3.1.1 lanio11CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio11CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.3.1.2 lanio11CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio11CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.3.1.3 lanio11CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio11CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.3.1.4 lanio11CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio11CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4 lanio11InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio11InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio11 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1 lanio11InputRegEntry OBJECT-TYPE SYNTAX Lanio11InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio11InputRegIndex } ::= { lanio11InputRegTable 1 } Lanio11InputRegEntry ::= SEQUENCE { lanio11InputRegIndex Integer32, lanio11InputRegName OCTET STRING, lanio11InputRegValue Opaque, lanio11InputRegModbusAdd Integer32, lanio11InputRegType OCTET STRING, lanio11InputRegScaleRatio Opaque, lanio11InputRegOffset Opaque, lanio11InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.1 lanio11InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio11InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.2 lanio11InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio11InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.3 lanio11InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio11InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.4 lanio11InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio11InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.5 lanio11InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio11InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.6 lanio11InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio11InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.7 lanio11InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio11InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.4.1.8 lanio11InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio11InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5 lanio11HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio11HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio11 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1 lanio11HoldingRegEntry OBJECT-TYPE SYNTAX Lanio11HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio11HoldingRegIndex } ::= { lanio11HoldingRegTable 1 } Lanio11HoldingRegEntry ::= SEQUENCE { lanio11HoldingRegIndex Integer32, lanio11HoldingRegName OCTET STRING, lanio11HoldingRegValue Opaque, lanio11HoldingRegModbusAdd Integer32, lanio11HoldingRegType OCTET STRING, lanio11HoldingRegScaleRatio Opaque, lanio11HoldingRegOffset Opaque, lanio11HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.1 lanio11HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio11HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.2 lanio11HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio11HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.3 lanio11HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio11HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.4 lanio11HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio11HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.5 lanio11HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio11HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.6 lanio11HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio11HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.7 lanio11HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio11HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.11.5.1.8 lanio11HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio11HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12 lanio12 OBJECT IDENTIFIER ::= { lanio 12 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1 lanio12BasicInfo OBJECT IDENTIFIER ::= { lanio12 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.1 lanio12Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio12BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.2 lanio12Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio12BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.3 lanio12ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio12BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.4 lanio12ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio12BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.5 lanio12ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio12BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.6 lanio12DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio12BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.7 lanio12CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio12BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.8 lanio12InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio12BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.1.9 lanio12HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio12BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.2 lanio12DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio12DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio12 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.2.1 lanio12DiscInputEntry OBJECT-TYPE SYNTAX Lanio12DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio12DiscInputIndex } ::= { lanio12DiscInputTable 1 } Lanio12DiscInputEntry ::= SEQUENCE { lanio12DiscInputIndex Integer32, lanio12DiscInputName OCTET STRING, lanio12DiscInputValue Integer32, lanio12DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.2.1.1 lanio12DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio12DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.2.1.2 lanio12DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio12DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.2.1.3 lanio12DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio12DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.2.1.4 lanio12DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio12DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.3 lanio12CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio12CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio12 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.3.1 lanio12CoilOutputEntry OBJECT-TYPE SYNTAX Lanio12CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio12CoilOutputIndex } ::= { lanio12CoilOutputTable 1 } Lanio12CoilOutputEntry ::= SEQUENCE { lanio12CoilOutputIndex Integer32, lanio12CoilOutputName OCTET STRING, lanio12CoilOutputValue Integer32, lanio12CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.3.1.1 lanio12CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio12CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.3.1.2 lanio12CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio12CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.3.1.3 lanio12CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio12CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.3.1.4 lanio12CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio12CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4 lanio12InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio12InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio12 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1 lanio12InputRegEntry OBJECT-TYPE SYNTAX Lanio12InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio12InputRegIndex } ::= { lanio12InputRegTable 1 } Lanio12InputRegEntry ::= SEQUENCE { lanio12InputRegIndex Integer32, lanio12InputRegName OCTET STRING, lanio12InputRegValue Opaque, lanio12InputRegModbusAdd Integer32, lanio12InputRegType OCTET STRING, lanio12InputRegScaleRatio Opaque, lanio12InputRegOffset Opaque, lanio12InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.1 lanio12InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio12InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.2 lanio12InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio12InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.3 lanio12InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio12InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.4 lanio12InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio12InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.5 lanio12InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio12InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.6 lanio12InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio12InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.7 lanio12InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio12InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.4.1.8 lanio12InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio12InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5 lanio12HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio12HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio12 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1 lanio12HoldingRegEntry OBJECT-TYPE SYNTAX Lanio12HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio12HoldingRegIndex } ::= { lanio12HoldingRegTable 1 } Lanio12HoldingRegEntry ::= SEQUENCE { lanio12HoldingRegIndex Integer32, lanio12HoldingRegName OCTET STRING, lanio12HoldingRegValue Opaque, lanio12HoldingRegModbusAdd Integer32, lanio12HoldingRegType OCTET STRING, lanio12HoldingRegScaleRatio Opaque, lanio12HoldingRegOffset Opaque, lanio12HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.1 lanio12HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio12HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.2 lanio12HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio12HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.3 lanio12HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio12HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.4 lanio12HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio12HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.5 lanio12HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio12HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.6 lanio12HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio12HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.7 lanio12HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio12HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.12.5.1.8 lanio12HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio12HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13 lanio13 OBJECT IDENTIFIER ::= { lanio 13 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1 lanio13BasicInfo OBJECT IDENTIFIER ::= { lanio13 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.1 lanio13Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio13BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.2 lanio13Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio13BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.3 lanio13ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio13BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.4 lanio13ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio13BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.5 lanio13ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio13BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.6 lanio13DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio13BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.7 lanio13CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio13BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.8 lanio13InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio13BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.1.9 lanio13HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio13BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.2 lanio13DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio13DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio13 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.2.1 lanio13DiscInputEntry OBJECT-TYPE SYNTAX Lanio13DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio13DiscInputIndex } ::= { lanio13DiscInputTable 1 } Lanio13DiscInputEntry ::= SEQUENCE { lanio13DiscInputIndex Integer32, lanio13DiscInputName OCTET STRING, lanio13DiscInputValue Integer32, lanio13DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.2.1.1 lanio13DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio13DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.2.1.2 lanio13DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio13DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.2.1.3 lanio13DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio13DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.2.1.4 lanio13DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio13DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.3 lanio13CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio13CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio13 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.3.1 lanio13CoilOutputEntry OBJECT-TYPE SYNTAX Lanio13CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio13CoilOutputIndex } ::= { lanio13CoilOutputTable 1 } Lanio13CoilOutputEntry ::= SEQUENCE { lanio13CoilOutputIndex Integer32, lanio13CoilOutputName OCTET STRING, lanio13CoilOutputValue Integer32, lanio13CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.3.1.1 lanio13CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio13CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.3.1.2 lanio13CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio13CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.3.1.3 lanio13CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio13CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.3.1.4 lanio13CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio13CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4 lanio13InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio13InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio13 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1 lanio13InputRegEntry OBJECT-TYPE SYNTAX Lanio13InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio13InputRegIndex } ::= { lanio13InputRegTable 1 } Lanio13InputRegEntry ::= SEQUENCE { lanio13InputRegIndex Integer32, lanio13InputRegName OCTET STRING, lanio13InputRegValue Opaque, lanio13InputRegModbusAdd Integer32, lanio13InputRegType OCTET STRING, lanio13InputRegScaleRatio Opaque, lanio13InputRegOffset Opaque, lanio13InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.1 lanio13InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio13InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.2 lanio13InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio13InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.3 lanio13InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio13InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.4 lanio13InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio13InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.5 lanio13InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio13InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.6 lanio13InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio13InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.7 lanio13InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio13InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.4.1.8 lanio13InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio13InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5 lanio13HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio13HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio13 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1 lanio13HoldingRegEntry OBJECT-TYPE SYNTAX Lanio13HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio13HoldingRegIndex } ::= { lanio13HoldingRegTable 1 } Lanio13HoldingRegEntry ::= SEQUENCE { lanio13HoldingRegIndex Integer32, lanio13HoldingRegName OCTET STRING, lanio13HoldingRegValue Opaque, lanio13HoldingRegModbusAdd Integer32, lanio13HoldingRegType OCTET STRING, lanio13HoldingRegScaleRatio Opaque, lanio13HoldingRegOffset Opaque, lanio13HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.1 lanio13HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio13HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.2 lanio13HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio13HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.3 lanio13HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio13HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.4 lanio13HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio13HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.5 lanio13HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio13HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.6 lanio13HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio13HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.7 lanio13HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio13HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.13.5.1.8 lanio13HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio13HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14 lanio14 OBJECT IDENTIFIER ::= { lanio 14 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1 lanio14BasicInfo OBJECT IDENTIFIER ::= { lanio14 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.1 lanio14Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio14BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.2 lanio14Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio14BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.3 lanio14ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio14BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.4 lanio14ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio14BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.5 lanio14ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio14BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.6 lanio14DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio14BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.7 lanio14CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio14BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.8 lanio14InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio14BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.1.9 lanio14HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio14BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.2 lanio14DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio14DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio14 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.2.1 lanio14DiscInputEntry OBJECT-TYPE SYNTAX Lanio14DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio14DiscInputIndex } ::= { lanio14DiscInputTable 1 } Lanio14DiscInputEntry ::= SEQUENCE { lanio14DiscInputIndex Integer32, lanio14DiscInputName OCTET STRING, lanio14DiscInputValue Integer32, lanio14DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.2.1.1 lanio14DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio14DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.2.1.2 lanio14DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio14DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.2.1.3 lanio14DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio14DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.2.1.4 lanio14DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio14DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.3 lanio14CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio14CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio14 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.3.1 lanio14CoilOutputEntry OBJECT-TYPE SYNTAX Lanio14CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio14CoilOutputIndex } ::= { lanio14CoilOutputTable 1 } Lanio14CoilOutputEntry ::= SEQUENCE { lanio14CoilOutputIndex Integer32, lanio14CoilOutputName OCTET STRING, lanio14CoilOutputValue Integer32, lanio14CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.3.1.1 lanio14CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio14CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.3.1.2 lanio14CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio14CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.3.1.3 lanio14CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio14CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.3.1.4 lanio14CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio14CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4 lanio14InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio14InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio14 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1 lanio14InputRegEntry OBJECT-TYPE SYNTAX Lanio14InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio14InputRegIndex } ::= { lanio14InputRegTable 1 } Lanio14InputRegEntry ::= SEQUENCE { lanio14InputRegIndex Integer32, lanio14InputRegName OCTET STRING, lanio14InputRegValue Opaque, lanio14InputRegModbusAdd Integer32, lanio14InputRegType OCTET STRING, lanio14InputRegScaleRatio Opaque, lanio14InputRegOffset Opaque, lanio14InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.1 lanio14InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio14InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.2 lanio14InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio14InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.3 lanio14InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio14InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.4 lanio14InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio14InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.5 lanio14InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio14InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.6 lanio14InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio14InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.7 lanio14InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio14InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.4.1.8 lanio14InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio14InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5 lanio14HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio14HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio14 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1 lanio14HoldingRegEntry OBJECT-TYPE SYNTAX Lanio14HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio14HoldingRegIndex } ::= { lanio14HoldingRegTable 1 } Lanio14HoldingRegEntry ::= SEQUENCE { lanio14HoldingRegIndex Integer32, lanio14HoldingRegName OCTET STRING, lanio14HoldingRegValue Opaque, lanio14HoldingRegModbusAdd Integer32, lanio14HoldingRegType OCTET STRING, lanio14HoldingRegScaleRatio Opaque, lanio14HoldingRegOffset Opaque, lanio14HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.1 lanio14HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio14HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.2 lanio14HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio14HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.3 lanio14HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio14HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.4 lanio14HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio14HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.5 lanio14HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio14HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.6 lanio14HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio14HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.7 lanio14HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio14HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.14.5.1.8 lanio14HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio14HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15 lanio15 OBJECT IDENTIFIER ::= { lanio 15 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1 lanio15BasicInfo OBJECT IDENTIFIER ::= { lanio15 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.1 lanio15Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio15BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.2 lanio15Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio15BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.3 lanio15ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio15BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.4 lanio15ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio15BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.5 lanio15ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio15BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.6 lanio15DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio15BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.7 lanio15CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio15BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.8 lanio15InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio15BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.1.9 lanio15HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio15BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.2 lanio15DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio15DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio15 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.2.1 lanio15DiscInputEntry OBJECT-TYPE SYNTAX Lanio15DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio15DiscInputIndex } ::= { lanio15DiscInputTable 1 } Lanio15DiscInputEntry ::= SEQUENCE { lanio15DiscInputIndex Integer32, lanio15DiscInputName OCTET STRING, lanio15DiscInputValue Integer32, lanio15DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.2.1.1 lanio15DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio15DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.2.1.2 lanio15DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio15DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.2.1.3 lanio15DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio15DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.2.1.4 lanio15DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio15DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.3 lanio15CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio15CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio15 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.3.1 lanio15CoilOutputEntry OBJECT-TYPE SYNTAX Lanio15CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio15CoilOutputIndex } ::= { lanio15CoilOutputTable 1 } Lanio15CoilOutputEntry ::= SEQUENCE { lanio15CoilOutputIndex Integer32, lanio15CoilOutputName OCTET STRING, lanio15CoilOutputValue Integer32, lanio15CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.3.1.1 lanio15CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio15CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.3.1.2 lanio15CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio15CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.3.1.3 lanio15CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio15CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.3.1.4 lanio15CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio15CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4 lanio15InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio15InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio15 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1 lanio15InputRegEntry OBJECT-TYPE SYNTAX Lanio15InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio15InputRegIndex } ::= { lanio15InputRegTable 1 } Lanio15InputRegEntry ::= SEQUENCE { lanio15InputRegIndex Integer32, lanio15InputRegName OCTET STRING, lanio15InputRegValue Opaque, lanio15InputRegModbusAdd Integer32, lanio15InputRegType OCTET STRING, lanio15InputRegScaleRatio Opaque, lanio15InputRegOffset Opaque, lanio15InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.1 lanio15InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio15InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.2 lanio15InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio15InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.3 lanio15InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio15InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.4 lanio15InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio15InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.5 lanio15InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio15InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.6 lanio15InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio15InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.7 lanio15InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio15InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.4.1.8 lanio15InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio15InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5 lanio15HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio15HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio15 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1 lanio15HoldingRegEntry OBJECT-TYPE SYNTAX Lanio15HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio15HoldingRegIndex } ::= { lanio15HoldingRegTable 1 } Lanio15HoldingRegEntry ::= SEQUENCE { lanio15HoldingRegIndex Integer32, lanio15HoldingRegName OCTET STRING, lanio15HoldingRegValue Opaque, lanio15HoldingRegModbusAdd Integer32, lanio15HoldingRegType OCTET STRING, lanio15HoldingRegScaleRatio Opaque, lanio15HoldingRegOffset Opaque, lanio15HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.1 lanio15HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio15HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.2 lanio15HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio15HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.3 lanio15HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio15HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.4 lanio15HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio15HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.5 lanio15HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio15HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.6 lanio15HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio15HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.7 lanio15HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio15HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.15.5.1.8 lanio15HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio15HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16 lanio16 OBJECT IDENTIFIER ::= { lanio 16 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1 lanio16BasicInfo OBJECT IDENTIFIER ::= { lanio16 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.1 lanio16Index OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the I/O module." ::= { lanio16BasicInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.2 lanio16Interface OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The interface of the I/O module(Com1 / Com2 / IP:Port)." ::= { lanio16BasicInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.3 lanio16ModbusID OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus ID(or NetID) of the I/O module." ::= { lanio16BasicInfo 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.4 lanio16ModuleName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the I/O module. Format: module name(nickname). " ::= { lanio16BasicInfo 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.5 lanio16ConnectionStatus OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The connection status of the I/O module." ::= { lanio16BasicInfo 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.6 lanio16DiscInputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the discrete input data." ::= { lanio16BasicInfo 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.7 lanio16CoilOutputAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the coil output data." ::= { lanio16BasicInfo 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.8 lanio16InputRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the input register data." ::= { lanio16BasicInfo 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.1.9 lanio16HoldingRegAmount OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The amount of the holding register data." ::= { lanio16BasicInfo 9 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.2 lanio16DiscInputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio16DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio16 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.2.1 lanio16DiscInputEntry OBJECT-TYPE SYNTAX Lanio16DiscInputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Discrete Input Table" INDEX { lanio16DiscInputIndex } ::= { lanio16DiscInputTable 1 } Lanio16DiscInputEntry ::= SEQUENCE { lanio16DiscInputIndex Integer32, lanio16DiscInputName OCTET STRING, lanio16DiscInputValue Integer32, lanio16DiscInputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.2.1.1 lanio16DiscInputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the discrete input data." ::= { lanio16DiscInputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.2.1.2 lanio16DiscInputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the discrete input data." ::= { lanio16DiscInputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.2.1.3 lanio16DiscInputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the discrete input data." ::= { lanio16DiscInputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.2.1.4 lanio16DiscInputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the discrete input data." ::= { lanio16DiscInputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.3 lanio16CoilOutputTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio16CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " ::= { lanio16 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.3.1 lanio16CoilOutputEntry OBJECT-TYPE SYNTAX Lanio16CoilOutputEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Coil Output Table" INDEX { lanio16CoilOutputIndex } ::= { lanio16CoilOutputTable 1 } Lanio16CoilOutputEntry ::= SEQUENCE { lanio16CoilOutputIndex Integer32, lanio16CoilOutputName OCTET STRING, lanio16CoilOutputValue Integer32, lanio16CoilOutputModbusAdd Integer32 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.3.1.1 lanio16CoilOutputIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the coil output data." ::= { lanio16CoilOutputEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.3.1.2 lanio16CoilOutputName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the coil output data." ::= { lanio16CoilOutputEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.3.1.3 lanio16CoilOutputValue OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the coil output data." ::= { lanio16CoilOutputEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.3.1.4 lanio16CoilOutputModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the coil output data." ::= { lanio16CoilOutputEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4 lanio16InputRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio16InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Input Register Table" ::= { lanio16 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1 lanio16InputRegEntry OBJECT-TYPE SYNTAX Lanio16InputRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio16InputRegIndex } ::= { lanio16InputRegTable 1 } Lanio16InputRegEntry ::= SEQUENCE { lanio16InputRegIndex Integer32, lanio16InputRegName OCTET STRING, lanio16InputRegValue Opaque, lanio16InputRegModbusAdd Integer32, lanio16InputRegType OCTET STRING, lanio16InputRegScaleRatio Opaque, lanio16InputRegOffset Opaque, lanio16InputRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.1 lanio16InputRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the input register data." ::= { lanio16InputRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.2 lanio16InputRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the input register data." ::= { lanio16InputRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.3 lanio16InputRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the input register data." ::= { lanio16InputRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.4 lanio16InputRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the input register data." ::= { lanio16InputRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.5 lanio16InputRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the Input Register data." ::= { lanio16InputRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.6 lanio16InputRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio16InputRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.7 lanio16InputRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows users to transform the Input Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Input Register value + Offset. " ::= { lanio16InputRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.4.1.8 lanio16InputRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the AI channel/Input Register is used to avoid signal oscillation that may result in instability to the measurement of the AI channel/Input Register value or system operations." ::= { lanio16InputRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5 lanio16HoldingRegTable OBJECT-TYPE SYNTAX SEQUENCE OF Lanio16HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Holding Register Table " ::= { lanio16 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1 lanio16HoldingRegEntry OBJECT-TYPE SYNTAX Lanio16HoldingRegEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { lanio16HoldingRegIndex } ::= { lanio16HoldingRegTable 1 } Lanio16HoldingRegEntry ::= SEQUENCE { lanio16HoldingRegIndex Integer32, lanio16HoldingRegName OCTET STRING, lanio16HoldingRegValue Opaque, lanio16HoldingRegModbusAdd Integer32, lanio16HoldingRegType OCTET STRING, lanio16HoldingRegScaleRatio Opaque, lanio16HoldingRegOffset Opaque, lanio16HoldingRegDeadband Opaque } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.1 lanio16HoldingRegIndex OBJECT-TYPE SYNTAX Integer32 (0..199) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the holding register data." ::= { lanio16HoldingRegEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.2 lanio16HoldingRegName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the holding register data." ::= { lanio16HoldingRegEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.3 lanio16HoldingRegValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the holding register data." ::= { lanio16HoldingRegEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.4 lanio16HoldingRegModbusAdd OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "The modbus address of the holding register data." ::= { lanio16HoldingRegEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.5 lanio16HoldingRegType OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The signal type of the holding register data." ::= { lanio16HoldingRegEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.6 lanio16HoldingRegScaleRatio OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio16HoldingRegEntry 6 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.7 lanio16HoldingRegOffset OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Scale Ratio setting and Offset setting allows user to transform the Holding Register value by linear transformation. The formula is as follow: Transformed Value = Scale Ratio x Holding Register value + Offset " ::= { lanio16HoldingRegEntry 7 } -- 1.3.6.1.4.1.34321.31.4206.3.3.16.5.1.8 lanio16HoldingRegDeadband OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The Deadband value of the Holding Register is used to avoid signal oscillation that may result in instability to the measurement of the Holding Register value or system operations." ::= { lanio16HoldingRegEntry 8 } -- 1.3.6.1.4.1.34321.31.4206.4 otherInfo OBJECT IDENTIFIER ::= { pmd4206 4 } -- 1.3.6.1.4.1.34321.31.4206.4.1 irTable OBJECT-TYPE SYNTAX SEQUENCE OF IrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "Internal Register Table" ::= { otherInfo 1 } -- 1.3.6.1.4.1.34321.31.4206.4.1.1 irEntry OBJECT-TYPE SYNTAX IrEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { irIndex } ::= { irTable 1 } IrEntry ::= SEQUENCE { irIndex Integer32, irName OCTET STRING, irValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.4.1.1.1 irIndex OBJECT-TYPE SYNTAX Integer32 (1..48) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the Internal Register." ::= { irEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.4.1.1.2 irName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The name of the Internal Register." ::= { irEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.4.1.1.3 irValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-write STATUS current DESCRIPTION "The value of the Internal Register." ::= { irEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.4.2 pueTable OBJECT-TYPE SYNTAX SEQUENCE OF PueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION "PUE Table" ::= { otherInfo 2 } -- 1.3.6.1.4.1.34321.31.4206.4.2.1 pueEntry OBJECT-TYPE SYNTAX PueEntry MAX-ACCESS not-accessible STATUS current DESCRIPTION " " INDEX { pueIndex } ::= { pueTable 1 } PueEntry ::= SEQUENCE { pueIndex Integer32, pueName OCTET STRING, pueTotalEnergy Opaque, pueITEnergy Opaque, pueValue Opaque } -- 1.3.6.1.4.1.34321.31.4206.4.2.1.1 pueIndex OBJECT-TYPE SYNTAX Integer32 (1..10) MAX-ACCESS read-only STATUS current DESCRIPTION "The index of the PUE." ::= { pueEntry 1 } -- 1.3.6.1.4.1.34321.31.4206.4.2.1.2 pueName OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "The nickname of the PUE." ::= { pueEntry 2 } -- 1.3.6.1.4.1.34321.31.4206.4.2.1.3 pueTotalEnergy OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the total facility energy." ::= { pueEntry 3 } -- 1.3.6.1.4.1.34321.31.4206.4.2.1.4 pueITEnergy OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of IT equipment energy." ::= { pueEntry 4 } -- 1.3.6.1.4.1.34321.31.4206.4.2.1.5 pueValue OBJECT-TYPE SYNTAX Opaque MAX-ACCESS read-only STATUS current DESCRIPTION "The value of the PUE." ::= { pueEntry 5 } -- 1.3.6.1.4.1.34321.31.4206.10 trapMessage NOTIFICATION-TYPE STATUS current DESCRIPTION " " ::= { pmd4206 10 } END